• Title/Summary/Keyword: packing

Search Result 1,963, Processing Time 0.026 seconds

Experiment and Simulation of 4-bed PSA for Hydrogen Separation from Multi-Component Mixture Gases (다성분 혼합 기체로부터 수소 분리를 위한 4-bed PSA 실험과 전산 모사)

  • Yang, Se-Il;Park, Ju-Yong;Jang, Seong-Cheol;Choi, Do-Young;Kim, Sung-Hyun;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.414-422
    • /
    • 2008
  • Adsorption experiments for $H_2$, $CH_4$, CO, $CO_2$ on activated carbon and zeolite 5A were performed by static volumetric method. A 4-bed pressure swing adsorption (PSA) process was to study separation of hydrogen from multi-component mixture gases ($H_2$ 72.2%, $CH_4$ 4.06%, CO 2.03%, $CO_2$ 21.6%). Dual-site langmuir (DSL) isotherm showed good or fair agreement with the experimental results. The optimum height of activated carbon layer was 55 cm with breakthrough results on the packing ratio of activated carbon to zeolite 5A. In PSA process, the effects of the process parameters such as total cycle time ($T_c$), ${\Delta}P$ at the provide purge step and adsorption pressure on the PSA performance were studied experimentally and theoretically.

Enhancement of PLED lifetime using thin film passivation with amorphous Mg-Zn-F

  • Kang, Byoung-Ho;Kim, Do-Eok;Kim, Jae-Hyun;Seo, Jun-Seon;Kim, Hak-Rin;Lee, Hyeong-Rag;Kwon, Dae-Hyuk;Kang, Shin-Won
    • Journal of Information Display
    • /
    • v.11 no.1
    • /
    • pp.8-11
    • /
    • 2010
  • In this study, a new thin films passivation technique using Zn with high electronegativity and $MgF_2$, a fluorine material with better optical transmittance than the sealing film materials that have thus far been reported was proposed. Targets with various ratios of $MgF_2$ to Zn (5:5, 4:6 and 3:7) were fabricated to control the amount of Zn in the passivation films. The Mg-Zn-F films were deposited onto the substrates and Zn was located in the gap between the lattices of $MgF_2$ without chemical metathesis in the Mg-Zn-F films. The thickness and optical transmittance of the deposited passivation films were approximately 200 nm and 80%, respectively. It was confirmed via electron dispersive spectroscopy (EDS) analysis that the Zn content of the film that was sputtered using a 4:6 ratio target was 9.84 wt%. The Zn contents of the films made from the 5:5 and 3:7 ratio targets were 2.07 and 5.01 wt%, respectively. The water vapor transmission rate (WVTR) was determined to be $38^{\circ}C$, RH 90-100%. The WVTR of the Mg-Zn-F film that was deposited with a 4:6 ratio target nearly reached the limit of the equipment, $1\times10^{-3}\;gm^2{\cdot}day$. As the Zn portion increased, the packing density also increased, and it was found that the passivation films effectively prevented the permeation by either oxygen or water vapor. To measure the characteristics of gas barrier, the film was applied to the emitting device to evaluate their lifetime. The lifetime of the applied device with passivation was increased to 25 times that of the PLED device, which was non-passivated.

Glass-alumina Composites Prepared by Melt-infiltration: II. Kinetic Studies (용융침투법으로 제조한 유리-알루미나 복합체: II. Kinetic 연구)

  • Lee, Deuk-Yong;Jang, Joo-Wung;Lee, Myung-Hyun;Lee, Jun-Kwang;Kim, Dae-Joon;Park, Il-Seok
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.145-152
    • /
    • 2002
  • Four commercial alumina powders having different particle size of $0.5{\mu}m,\;2.8{\mu}m,\;12{\mu}m,\;and\;45{\mu}m$ were presintered at 1120$^{\circ}C$ for 2h and then lanthanum aluminosilicate glass was infiltrated at 1100$^{\circ}C$ for 2h in the interval of 0.1h to investigate the penetration kinetic of the glass into the alumina preforms. The infiltration distance is parabolic with respect to time as described by the Washburn equation and the penetration rate constant, K, increases with raising the alumina particle size. The strength of glass-alumina composites increases as the alumina particle size reaches to 2.8${\mu}m$ due to the increase in packing, however, decreases with further increasing the alumina particle size. The fracture toughness of the composites rises with increasing the alumina particle size due to the crack bowing and the interaction between crack and alumina particles.

A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY (개별 치아 트레이의 재료와 형태에 따른 인상체의 정밀성에 관한 연구)

  • Ryu, Duck-Woo;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.242-254
    • /
    • 2000
  • Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin. $Futar^{(R)}$ occlusion. $Blu-mousse^{(R)}$) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by $X-PLAN360d^{(R)}$ to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows: 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm-marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less marginal discrepancy than groups with 0.5mm-marginal-vent-space (p<0.05). In summary these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.

  • PDF

A Study on the Revision of the ISBP745 and Practical Adaptation in the field (국제표준은행관행(ISBP745)의 변경내용과 실무적용에 관한 연구)

  • Lim, Jaewook
    • International Commerce and Information Review
    • /
    • v.16 no.5
    • /
    • pp.87-114
    • /
    • 2014
  • The Uniform Customs and Practice for Documentary Credits (UCP) is a set of rules on the issuance and use of letters of credit. Historically, the commercial parties, particularly banks, have developed the techniques and methods for handling letters of credit in international trade finance. This practice has been standardized by the ICC (International Chamber of Commerce) by publishing the UCP in 1933 and subsequently updating it throughout the years. The ICC has developed and moulded the UCP by regular revisions, the current version being the UCP600. This latest version, called the UCP600, formally commenced on 1 July 2007. During the revision process, notice was taken of the considerable work that had been completed in creating the International Standard Banking Practice for the Examination of Documents under Documentary Credits (ISBP), ICC Publication 745. This publication has evolved into a necessary companion to the UCP for determining compliance of documents with the terms of letters of credit. It is the expectation of the Drafting Group and the Banking Commission that the application of the principles contained in the ISBP, including subsequent revisions thereof, will continue during the time UCP 600 is in force. This paper focuses on documents including various certificates, Packing List, Weight List, Beneficiary's Certificate, Analysiis, Inspection, Health, Phytosanitary, Quantity and Quality Certificates, Courier Receipts, Shipping Advice etc. and suggests some implications in the field.

  • PDF

Column Tests for the Design of PRB System using CFW (음식폐기물 탄화재로 충진된 PRB설계법 제안을 위한 컬럼실험)

  • Han, Jung-Geun;Yoon, Won-Il;Jung, Dong-Ho;Kim, Yong-Soo;Lee, Jong-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.35-43
    • /
    • 2011
  • Permeable Reactive Barriers (PRB) method is an economical method that does not require any other methods to be operated once it is installed as it controls of groundwater flow in the barrier, which is inserted a reactive material on the way of pollutant. The major dominant element of PRB is a reactive material in the reactive wall, and such factors as purification efficiency and used time based on the chemical and physical features in between the reactant and pollutant. High purification efficiency can be expected when a rational design that is synthetically considered in features of packing density, operation period, and adsorption reactant of pollutant. A column test was conducted for an application test using CFW as its adsorption reactant in order to remove copper($Cu^{2+}$) in the PRB system. The CFW was used for the reactant and selected inflow speed, density and thickness of PRB as its necessary factors for design of PRB. As a result of the experiment, the removal efficiency decreased as operating time of PRB increased and the efficiency linearly increased upon the length. Therefore, it is confirmed that the thickness of reactive materials in PRB system can be designed using the proposed formula considering purification time and density of CFW.

Emergency bleeding control in a mentally retarded patient with active oral and maxillofacial bleeding injuries: report of a case (구강악안면 손상 후 과도한 출혈을 보인 정신지체 응급환자에서 신속지혈 예: 증례보고)

  • Mo, Dong-Yup;Yoo, Jae-Ha;Choi, Byung-Ho;Sul, Sung-Han;Kim, Ha-Rang;Lee, Chun-Ui
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.303-308
    • /
    • 2010
  • Excessive oral and maxillofacial bleeding causes upper airway obstruction, bronchotracheal and gastric aspiration and hypovolemic shock. Therefore, the rapid and correct bleeding control is very important for saving lives in the emergency room. Despite the conventional bleeding control methods of wiring (jaw fracture, wound suture and direct pressure), continuous bleeding can occur due to the presence of various bleeding disorders. There are five main causes for excessive bleeding disorders in the clinical phase; (1) vascular wall alteration (infection, scurvy etc.), (2) disorders of platelet function (3) thrombocytopenic purpura (4) inherited disorders of coagulation, and (5) acquired disorders of coagulation (liver disease, anticoagulant drug etc.). In particular, infections can alter the structure and function of the vascular wall to a point at which the patient may have a clinical bleeding problem due to vessel engorgement and erosion. Wound infection is a frequent cause of postoperative active bleeding. To prevent postoperative bleeding, early infection control using a wound suture with proper drainage establishment is very important, particularly in the active bleeding sites in a contaminated emergency room. This is a case report of a rational bleeding control method by rapid wiring, wound suture with drainage of a rubber strip & iodoform gauze and wet gauze packing, in a 26-year-old male cerebral palsy patient with active oral and maxillofacial bleeding injuries caused by a traffic accident.

TREATMENT OF IMPACTED MANDIBULAR FIRST MOLAR BY SURGICAL EXPOSURE : A CASE REPORT (매복된 하악 제1대구치의 외과적 노출술을 이용한 치험례)

  • Cho, Yun-Jung;Park, Young-Ok;Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.322-328
    • /
    • 2007
  • The first molar is important for mastication and also it plays roles to formation of vertical occlusion and growth of jaw bone after mixed dentition. Impaction of mandibular first molar can result in a short lower facial height, formation of a follicular cyst, pericoronal inflammation, resorption of the roots of neighboring teeth and malocclusion. The options of treatment plans are as follows; observation, surgical exposure, orthodontic traction, surgical relocation and extraction. Surgical exposure could be considered as a basic treatment plan. For surgical exposure it is important to maintain patent channel between the crown and the normal eruptive path into the oral cavity, many techniques including cementation of a celluloid crown, packing with zinc oxide-eugenol surgical pack are used. In these cases, we could observe spontaneous eruption of mandibular first molar using surgical exposure with or without removal of odontoma. Also we could obtain the main patency effectively and conveniently by using surgical pack and translucent retainer.

  • PDF

Search of Characteristic for Dose Distribution Presented by Multi­isocentric Stereotactic Radiosurgical Plan Using Linear Accelerator (선형 가속기를 이용한 정위적 방사선 수술시 병소내 선량분포의 특성조사)

  • 최경식;오승종;이형구;최보영;전흥재;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.225-233
    • /
    • 2003
  • The goal of a radiation treatment plan is to deliver a homogeneous dose to a target with minimal irradiation of the adjacent normal tissues. Dose uniformity is especially important for stereotactic radiosurgery using a linear accelerator. The dose uniformity and high dose delivery of a single spherical dose distribution exceed 70%. This also results with a similar stereotactic radiosurgical plan using a Gamma Knife. The dose distribution produced in a stereotactic radiosurgical plan using a Gamma Knife and Linear accelerator is spherical, and the application of the sphere packing arrangement in a real radiosurgical plan requires much time and skill. In this study, we found a characteristic of dose distribution with transformation of beam parameters that must be considered in a radiosurgical plan for effective radiosurgery. First, we assumed a cylinder type tumor model and a cube type tumor model. Secondly, the results of the tumor models were compared and analyzed with dose profiles and DVH_(Dose Volume Histogram) representative dose distribution. We found the optimal composition of beam parameters_(i.e. collimator size, number of isocenter, gap of isocenters etc.), which allowed the tumor models to be involved in the isodose curve at a high level. In conclusion, the characteristics found in this study are helpful for improving the effectiveness and speed of a radiosurgical plan for stereotactic radiosurgery.

  • PDF

Application of Gamma Irradiation and Its Convergent Treatments on Several Varieties of Oriental Hybrid Lily to Control Leaf Blight (수출용 오리엔탈 백합 품종 잎마름병 방제를 위한 감마선 및 화학 대체제 융복합 처리 효과)

  • Kim, Ji-Hoon;Koo, Tae-Hoon;Hong, Sung-Jun;Yun, Sung-Chul
    • Research in Plant Disease
    • /
    • v.20 no.2
    • /
    • pp.79-86
    • /
    • 2014
  • In order to seek more eco-friend, economic and safer quarantine method than current methyl bromide fumigation, the convergent treatment with 200 Gy of gamma irradiation and several chemicals such as nano-siver particles (NSS), sodium dichloroisocyanurate (NaDCC) was tried on the cuttings of lily in the packing of catonnage box for export. With 6 independent experiments of gamma irradiation on the three lily cultivars, cvs. Siberia, Le reve and Sorbonne, incidence and severity of lily leaf blight was investigated on leaves and petals at 8-d after infection. 200 Gy of gamma irradiation decreased at 13-25% of severity on the leaf of Sorbonne, but it increased at 2-5% of severity on the leaf of Siberia and Le reve. Chemical substitutes such as NSS and NaDCC were not effective to control of lily blight on cuttings. By 200 Gy of gamma irradiation treatment, chlorophyll contents were statistically significantly decreased at 12-d after irradiation and the longevities vaselife of fully open flower of Siberia and Sorbonne were increased at 0.4 to 1.2 days. In addition, the relative fresh weights of the gamma irradiated cuttings were severely dried compared to the non-irradiated control. On the other hands, the symptoms of phyto-toxicity of high dose gamma irradiation at 1 or 2 kGy on cv. Siberia were to be blight at the tip of bloom, bent necks of flower, and delayed the process of flowering.