휴대형 혈액가스 분석시스템의 구현 (Implementation on the Portable Blood Gas Analyzer)

  • 강성철;정도운;배진우;손정만;심윤보;전계록
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.1032-1036
    • /
    • 2006
  • In this study, we implement the potable blood gas analyzer measuring pH, $pCO_2\;and\;pO_2$ of the arterial blood. The implemented system by this study is divided into hardware and software part and also the hardware portion is parted by mechanism and electronic circuit mit. The system program is composed of operating, washing, correcting and measuring program. And to correct the system, two-point calibration method is used, one-point calibration method is also added for more accuracy, and system program is coded. For verifying the implemented system, We examine to response property of each electrode. And evaluate accuracy of the system using standard reagent and was construed as statistical.

  • PDF

근적외 토앙분석기를 이용한 토양의 이화학적 성질분석 (Use of NIR Soil Analyzer for Measuring Chemical Properties of Field Soil)

  • 유관식;조래광;박우철;김복진
    • 한국토양비료학회지
    • /
    • 제34권4호
    • /
    • pp.278-283
    • /
    • 2001
  • 근적외 이용 토양분석기에 의한 토양수분, 유기물, 전질소 측정과 그 외 토양의 여러 가지 이화학 성분에 대한 측정결과를 검토하였다. 토양시료를 몰탈로 갈아서 토양입자를 0.2mm의 체를 통과시킨 140점의 토양시료를 85점은 근적외 토양분석기의 표준곡선을 작성하고 나머지 55점의 토양시료는 표준곡선을 이용하여 추정한 토양의 이화학성 중에서 토양수분, 토양 pH, 유기물, 전질소 CEC, 치환성 Ca, Mg, K 및 유효규산함량은 근적외 토양분석기로 동시에 추정할 수 있어 시비처방을 위한 토양의 비옥도를 판정하는데 유용하게 이용할 수 있을것으로 생각된다.

  • PDF

휴대형 혈액가스분석 시스템의 구현 및 성능평가 (Implementation on the Portable Blood Gas Analyzer and Performance Estimation)

  • 정도운;전계록;배진우;김길중;심윤보
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.34-43
    • /
    • 2003
  • 본 연구에서는 동맥혈액 내의 혈액가스(pH, $pCO_2$, $pO_2$)를 측정할 수 있는 휴대용 혈액가스 분석 시스템을 구현하였다. 구현된 시스템은 크게 하드웨어부와 소프트웨어부로 구분하였으며, 하드웨어부는 메커니즘과 전자회로부로 구분하여 설계하였다. 소프트웨어부는 각 모듈별로 작성하였으며, 운용프로그램, 세척프로그램, 교정프로그램, 측정프로그램 등으로 구성하였다. 그리고 시스템의 정확한 교정을 위하여 2점 교정방식을 사용하였고, 1점 보정방식을 추가 적용하여 측정의 정확성을 높이고자 하였다. 시스템의 평가를 위하여 각 전극의 감응특성을 조사하였다. 그리고 정확도 평가를 위하여 표준용액을 이용하여 측정실험을 하고 통계적인 분석을 하였다. 그 결과 계수변화율이 1.12이내이었고, 최대오차가 1.298%이내인 정확도를 나타내었으며, 휴대형 ABGA의 개발 가능성을 확인하였다.

신경계 중환자의 측정부위별 맥박 산소포화도의 비교 (Comparison of Arterial Oxygen Saturation Measured by Pulse Oximetry at Different Sensor Sites in Neurocritical Patients)

  • 전민정;황선경
    • 중환자간호학회지
    • /
    • 제16권1호
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : This study aimed to compare peripheral pulse oxygen saturation (SpO2) values, measured at different monitoring sites, and arterial oxygen saturation (SaO2) of neurocritical patients. Methods : The study included 110 patients admitted to the neurosurgical intensive care unit of a university hospital. The patients' SpO2 values were measured in their index fingers, both second toes, both earlobes, and foreheads, using the patient monitoring system. These values were compared with the standard value of SaO2 measured using a blood gas analyzer. Data were analyzed using descriptive values, Pearson's correlation coefficients, Lin's concordance correlation coefficients (CCC), and Bland-Altman plots. Result : Regardless of the measuring site, SpO2 was correlated with the paired measurements of SaO2 (r=.40~.60, p<.001, CCC range=.40~.58). No significant bias in paired measurements of SpO2 and SaO2 was observed at all sites (-0.06~0.19%, p>.05). SpO2 values at the left finger and right earlobe had the narrowest range, with a 95% limits of agreement (LOA) (left finger -3.04~2.93% and right earlobe -3.18~2.79%). SpO2 at the index finger, on the side without an arterial catheter, had a narrower range of 95% LOA than that of the opposing finger (-3.00~2.97% vs. -3.73~3.26%). Conclusion : SpO2 at the finger without an arterial catheter had the highest level of precision. This study suggests using the index finger, on the side without an arterial catheter, for pulse oximetry in neurocritical patients.

형광물질을 이용한 대기 중 오존 Passive Sampler의 개발 (Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone)

  • 임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.