• Title/Summary/Keyword: pH values

Search Result 5,904, Processing Time 0.038 seconds

Studies on the Standardization of pH Measurement System (pH 측정 시스템의 표준화에 관한 연구)

  • Lee, Hwa Shim;Kim, Myung Soo;Kim, Jin Bok;Oh, Sang Hyup
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.432-442
    • /
    • 1998
  • Since the definition of pH, $pH=-Ioga_H$ is based on a single ion activity, pH values can not be determined with measurement itself, but require an approximation method. They are derived from EMF measurement of a liquid junction free cell using hydrogen and Ag/AgCl electrodes. Primary standard materials with certified pH values can be obtained with this approximation method. Standard buffer solutions are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values can be obtained with this approximation method. Standard buffer solution are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values of sample solutions. To certify the pH values, we have established the system for the primary standard measurement and certified the pH of buffer solutions in the range of 1.6∼12.5 pH unit within uncertainty of ${\pm}0.005$ pH unit.

  • PDF

Effect of pH on Rheological Properties of Dysphagia-Oriented Thickened Water

  • Yoon, Seung-No;Yoo, Byoungseung
    • Preventive Nutrition and Food Science
    • /
    • v.21 no.1
    • /
    • pp.73-77
    • /
    • 2016
  • Flow and dynamic rheological properties of thickened waters prepared with commercial food thickeners were investigated at different pH levels (3, 4, 5, 6, and 7). The commercial xanthan gum (XG)-based thickener (thickener A) and starch-based thickener (thickener B), which have been commonly used in a domestic hospital and nursing home for patients with swallowing difficulty (dysphagia) in Korea, were selected in this study. Thickened samples with both thickeners at different pH levels showed high shear-thinning flow behaviors (n=0.08~0.22). Thickened samples at pH 3 showed higher n values and lower consistency index (K) values when compared to those at other pH levels. The K values of thickener A increased with an increase in pH level, while the n values decreased, showing that the flow properties greatly depended on pH. There were no noticeable changes in the K values of thickener B between pH 4 and 7. At pH 3, the thickened water with thickener A showed a higher storage modulus (G') value, while that with thickener B showed a lower G'. These rheological parameters exhibited differences in rheological behaviors between XG-based and starch-based thickeners, indicating that the rheological properties of thickened waters appear to be greatly influenced by the acidic condition and the type of food thickener. Appropriately selecting a commercial food thickener seems to be greatly important for the preparation of thickened acidic fluids with desirable rheological properties for safe swallowing.

Modelling of a pH titration process and design of a self-tuning pH controller (pH 적정공정의 모델링 및 자기동조 제어기 설계)

  • 김우태;이혁희;최태호;이지태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.476-481
    • /
    • 1988
  • In this paper a pH process of a weak acid with a strong base is modeled into a bilinear form, and a self-tuning pH control algorithm which is robust against initial values of solution and disturbances is presented. The control algorithm employs the recursive least square method for the parameter estimation and the generalised minimum variance criterion as the objective function. The computer simulation shows that the tracking of desired pH values is obtained in satisfactory manner regardless of the initial values chosen for the process.

  • PDF

pH and Colour Characteristics of Carcasses of Broilers Fed with Dietary Probiotics and Slaughtered at Different Ages

  • Karaoglu, Mevulut;Aksu, M.I.;Esenbuga, N.;Macit, M.;Durdag, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.4
    • /
    • pp.605-610
    • /
    • 2006
  • The objective of the present experiment was to determine the effects of slaughtering at different ages and the use of a commercial probiotic (115-Biogallinox) in broiler diets on the color properties of carcasses, during the first 24 h following slaughter. Ross 308 male broiler chickens obtained from a commercial hatchery were raised to either 35 or 42 days of age. Chickens were fed with different levels of probiotic ($P_0$: 0.0%, $P_1$: 0.1% and $P_2$: 0.2%) containing Saccharomyces cerevisiae during the experimental period. At the end of the trial all birds were slaughtered and then stored at $3^{\circ}C$ for 24 h. The pH and skin colour of carcasses were determined 1, 3, 7, 10, 13, 17 and 24 h after slaughter. Although the use of probiotic and post-mortem ageing time affected the pH (p<0.01), it was not affected by slaughter age (35 and 42 days) (p>0.05). The highest pH values occurred in carcasses of broilers fed 0.2% probiotic. The pH values of carcasses decreased with post-mortem ageing time (p<0.01). Main factors (treatment, slaughter age and post-mortem ageing time) had an effect on colour ($L^*$, $a^*$ and $b^*$) values (p<0.01). $L^*$ values of 42d-old slaughter and $P_2$ group were lower than those of 35d-old slaughter and other probiotic groups. The $a^*$ and $b^*$ values of 35d-old slaughter were lower than those of 42d-old slauhgter. The $a^*$ and $b^*$ values increased during post-mortem ageing (p<0.01). It was determined that changing of the colour traits of broiler carcasses was correlated with probiotic, pH and post-mortem ageing time. Also, it was observed that darkness of carcass colour increased as time progressed.

Effect of pH Variation on the Properties of the Hydroxyapatite Precipitates and Powder Prepared by the Wet Method (습식법으로 제조한 수산화아파타이트 침전입자와 분말의 특성에 미치는 pH변화의 영향)

  • 신용규;정형진;김병호
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.2
    • /
    • pp.157-166
    • /
    • 1989
  • The effect of pH variation in starting solution on the characteristics of hydroxyapatite precipitates and powder prepared by the wet method was investigated. Hydroxyapatite precipitates was agglomerated, the average agglomerated particle size was decreased in the range from 2 to 6${\mu}{\textrm}{m}$ with increasing pH values in starting solution. The aspect ratio of rod-shaped hydroxyapatite particle was rapidly increased at pH 11 and 11.5. The maximum specific surface area, 91.1$m^2$/g, was at pH 10.5. Dried powder prepared at high pH values contained more minutes CO2 than that prepared at low pH values. The poor crystallinity was maintained up to $600^{\circ}C$ regardless of the pH values in starting solutions. However, the second phase or high crsytalline hydroxypatite phase appeared above 80$0^{\circ}C$. In pH 9.5 and pH 10, $\beta$-whitlockite transformed to $\alpha$-whitlockite at 120$0^{\circ}C$, while in pH 10.5-11.5, hydroxyapatite phase was maintained up to 120$0^{\circ}C$.

  • PDF

Study on Anomalous Polarographic Behavior of Cd (II) in Tartrate Solution (타르타르酸염支持溶液에서의 Cd (II) 폴라로그람의 異常波에 關한 硏究)

  • Koh, Kwang-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.179-184
    • /
    • 1967
  • The polarograms of Cd(II) in 0.15M tartrate solution were investigated in the range of pH values from 6.0 to 12.6 at 20$^{\circ}and 25$^{\circ}C. Up to pH value of 7.8, the limiting current and the halfwave potential were found to be constant, and when compared with the nitrate solution of the same $Cd^{++}$ concentration at the same ionic strength, the limiting current decreased by 28% and the halfwave potential shifted by -0.05 volt. The values of limiting current sharply decreased as the pH value exceeded 8.2 and the minimum values appeared at the pH values of 11.2~11.4. The values of halfwave potential gradually decreased as the pH value increased over 8.2 and the value of -0.78 volt was obtained at the pH value of 12.6. Possible mechanisms of electrode reaction were suggested and the anomalous behavior of reduction waves of Cd(II) in tartrate solution up to pH value of 9.4 was discussed.

  • PDF

Surface pH Of The Northeastern Pacific Ocean

  • Park, Kilho
    • 한국해양학회지
    • /
    • v.1 no.1_2
    • /
    • pp.1-6
    • /
    • 1966
  • A latitudinal, differential pH distribution is observed in the Northeastern Pacific Ocean with a pH range of 8.15 at high latitude (42 N) to 8.29 at low latitude (23 N). These pH values are generally greater than the calculated equilibrium pH with respect to atmospheric carbon dioxide. If we assume that the calculated equilibrium pH values ae valid, then the surface waters are undersaturated with respect to the atmospheric carbon dioxide during April to June 1966. A high surface pH value of about 8.26 was observed immediately south of the SubarcticBoundary zone near 170 W. This value differs from the equilibration pH by as much as 0.1 unit.

  • PDF

Estimations on the Water Purification of Forest by Analyzing Water Quality Variations in Forest Hydrological Processes (산지(山地) 물순환(循環) 소과정(素過程)에 있어서 수질변화(水質變化)의 추적분석(追跡分析)에 의한 산림(山林)의 환경적(環境的) 정화기능(淨化機能)의 계량화(計量化) 연구(硏究))

  • Lee, Heon-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.1
    • /
    • pp.56-68
    • /
    • 1997
  • This study was carried out to evaluate the capacity of environment purification of forest and to reveal formation processes of stream water quality by evaluating water quality variations in forest hydrological processes. Water quantity, pH, electric conductivity(EC), dissolved oxygen(DO), and dissolved matter concentrations were monitored in open rainfall, throughfall, stemflow, litter flow and short-term stream flow for one unit storm, and also for those were monitored in long-term stream flow in Palgong, Yongsung, and Daedong catchments. The results were summarized as follows; 1. pH and DO values of stream flow were increased as the flux increased but EC values were decreased. 2. pH values of stemflow and throughfall were decreased with the lapse of rainfall time with lower values than open rainfall. Arid EC values were higher in initial rainfall period but lower gradually with the lapse of time than open rainfall. In litter flow, pH values were lower than open rainfall but EC values were higher. In stream flow, pH values of stream flow showed a high level in initial rainfall period and decreased remarkably with the lapse of time, but it recovered after the rainfall stopped. And however, the values of EC showed almost reverse tendency. DO values of litter flow and stream flow were decreased gradually with the lapse of time in litter flow and stream flow but there were no any tendency in open rainfall, stemflow and throughfall. 3. pH values of stemflow and throughfall in Quercus acutissima were higher than in Pinus densiflora, but EC values were lower. Total amount of canons in stemflow was higher in Pinus densiflora than in Quercus acutissima. 4. pH, DO, EC and total amount of cation values in hydrological processes were in the order of; litter flow

  • PDF

Permeability Characteristics of Clays with Various pH Values (pH 변화에 따른 점토의 투수특성)

  • 장병욱;강상욱;김성필;차경섭
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.6
    • /
    • pp.99-105
    • /
    • 2002
  • A series of physical properties and rigid wall permeability tests were performed on two clays to investigate changes in permeability characteristics of clays with various pH values. Results of the study are as follows. As pH values were increased, coefficients of permeability of S-clay(clay fraction 18%) and J-clay(clay fraction 30%) were decreased in 3 and 4 times, respectively. Variation of coefficient of permeability of J-clay was considerably related to clay fraction. It can be said that coefficient of permeability of clays tested was increased, as pH values were decreased. This was because of increase in effective voids caused by decrease in thickness of diffused double layer, that is, change in soil structures and effective grain sizes.

X-Ray Diffraction Studies of Uranyl Hydrolysis Precipitates Synthesized in Neutral to Alkaline Aqueous Solutions

  • 박용준;표형렬;김원호;전관식
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.10
    • /
    • pp.925-929
    • /
    • 1996
  • Uranyl hydrolysis precipitates were obtained by increasing pH value of aqueous uranyl solution in the range of neutral to alkaline pH value and their phase transformation during the solubility experiment under various conditions has been examined. The precipitates formed in the hydrolysis reaction of uranyl ion had a layered structure such as a meta-schoepite phase, a schoepite structure, or a mixed phase of meta-schoepite and schoepite. Phase transformation between them was strongly dependent on the pH value at which the precipitate was formed. The distance between the layers in meta-schoepite or schoepite phase was ∼7.35 Å, and it was increased with the pH value at which the precipitate was synthesized as well as the pH values of the aqueous solution. The phase transformation from a meta-schoepite to schoepite was fast for the precipitates formed at low pH values, however, it was not the case for the precipitates formed at high pH values. A small difference of pH value in aqueous solution gave a great change on its solubilities near pH 9.7, because a layered structure of the precipitates became amorphous above that pH value. Greater solubility for the precipitate formed at higher pH value can be explained from the fact that the precipitates formed at low pH value had a better crystallinity and also that the precipitates formed at higher pH value has a slower rate of crystallization.