• Title/Summary/Keyword: pH test

Search Result 4,131, Processing Time 0.035 seconds

A Study on the Reinforcement and Environmental Impact of LW Injection (LW주입에 의한 지반보강 및 환경영향성에 관한 연구)

  • Chun, Byungsik;Do, Jongnam;Sung, Hwadon;Lim, Jooheon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.121-131
    • /
    • 2006
  • This study is performed to examine the ground reinforcement effect and the environmental impact of LW injection, which is widely used during the excavation of high-rise apartment buildings. In addition, it proved that by conducting field exploration and laboratory test the engineering ground reinforcement effect of LW injection in the ground has low coefficient of permeability. The environmentally friendly aspect was evaluated through an assessment of environmental impact. The results of laboratory test shows that LW coagulating material with SC type soil structure has significant improvement of uniaxial compressive strength, increasing by three times and the shear strength increasing by twice, coefficient of permeability decreasing six to seven times. And the result of environmental impact tests show that from 6 hour after where the pH increases until 7.96 to initially it diminished, it started and to 80 hour after it recovered a pH 7.25 initially with 7.30. The chemical composition analysis test result that unpolluted water and polluted water hydrogen ion concentration (pH) show that the unpolluted water pH 7.36, polluted water pH 7.85, which is inside the Ministry of Environment standard of drinking water (the pH 5.8~8.5). The assessment of environmental impact and chemical analysis test also demonstrate that the LW coagulating material is environmentally friendly. In the $Cr^{6+}$ and the salinity detection test, it was proven that the salinity is slight and the $Cr^{6+}$ is not detected.

  • PDF

Evaluation of Flow Accelerated Corrosion of Carbon Steel with Rotating Cylinder (Rotating cylinder를 이용한 탄소강의 유동가속부식 평가)

  • Park, Tae Jun;Lee, Eun Hee;Kim, Kyung Mo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.257-262
    • /
    • 2012
  • Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. Rotating cylinder FAC test facility was designed and fabricated and then performance of the facility was evaluated. The facility is very simple in design and economic in fabrication and can be used in material and chemistry screening test. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO), and temperature. Fluid velocity is controlled with rotating speed of the cylinder with a test specimen. FAC test of SA106 Gr. B carbon steel under 4 m/s flow velocity was performed with the rotating cylinder at DO concentration of less than 1 ppb and of 1.3 ppm. Also a corrosion test of the carbon steel at static condition, that is at zero fluid velocity, of test specimen and solution was performed at pH from 8 to 10 for comparison with the FAC data. For corrosion test in static condition, the amount of non adherent corrosion product was almost constant at pH ranging from 8 to 10. But adherent corrosion product decreased with increasing pH. This trend is consistent with decrease of Fe solubility with an increase in pH. For FAC test with rotating cylinder FAC test facility, the amount of non adherent corrosion product was also almost same for both DO concentrations. The rotating cylinder FAC test facility will be further improved by redesigning rotating cylinder and FAC specimen geometry for future work.

Consideration About the Bacterial Endotoxin Test Showing False Positive Test Result When Performing LAL Test (LAL Test에서 위양성을 나타내는 원인들에 대한 고찰)

  • Hwang, Ki-Young;Cho, Yong-Hyun;Lee, Yong-Suk;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.156-158
    • /
    • 2009
  • Purpose: Since radiopharmaceuticals are intended for human administration, it is imperative that we should undergo quality control very strictly. Now almost all the PET laboratories have adopted Bacterial Endotoxin Test as the stand quality control method to monitor whether pyrogen is free or not in the product vial containing crude solution. The aim of this study is to find out the reason why false positive result is observed when using commercially available test vial. Materials and Methods: For this experiment, we used commercially available single test kit (Associates of Cape Code. Inc. USA) and we made pH samples by mixing each buffer whose pH ranges are 1.0 to 12.0. Otherwise we made Ethanol samples diluted with distilled water. After making test samples, it added 0.2 mL to the test vial. Assay mixture in the test vial was incubated in a water bath (Chang Shin Co. KOR) for 60 min at $35{\pm}2^{\circ}C$. Results: After incubation period ($60{\pm}1^{\circ}C$), we inverted the test vial about $180^{\circ}$ To know what pH and how many percentage of Ethanol (Fisher Scientific Korea. Ltd) will affect the reaction. With pH buffer, false positive result was observed at pH 1.0 to 5.0 and 7.7 to 12.6 but at pH 5.2 to.7.5, the test results show negative. It's very strange that we couldn't observe negative test result with Tris buffer at pH 8.4, 8.6, 8.8, 9.0. in other case Ethanol, the test result was seen with 5 to 10% Ethanol. But to my surprise we could see very thick gel formation with 100% Ethanol. Conclusions: In this study, we could notice that pH which is too much acidic or alkalic or high concentrated Ethanol would affect Bacterial Endotoxin Test result. As you know, LAL test is sensitive and very reliable method. Therefore, we are needed to elicit the accurate test result as possible as we can.

  • PDF

Potential Environmental Influences in Soil by Accidental Fluorine (F) Leakage, Using Leaching Test (용출시험을 통한 불산 누출사고지역의 토양 내 불소(F)의 거동특성)

  • Kim, Doyoung;Lee, Junseok;Kwon, Eunhye;Lee, Hyun A;Yoon, Hye-On;Lee, Sanghoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.234-239
    • /
    • 2015
  • Various leaching tests were applied to the soil affected by accidental leakage of HF in an industrial area in Korea. Three different leaching methods including pH-stat, continuous batch leaching, and column tests were adopted to assess leaching characteristics and mobility of fluorine(F) in soil and the potential risks to ecosystem. Both natural and spiked samples were used for the leaching tests. F concentrations in the batch tests increased by leaching rapidly in the early stage of leaching and then maintained rather constant levels. Column leaching test also show similar result to that of the batch test. pH also controlled the leaching behavior of the soil. With increasing pH, more F was released in the pH-stat test. This is mainly due to the competition and exchange with hydroxyl ions, as pH increase to the alkaline range. Most of the F released by the accident seem to have removed in the very early stage of leaching, whereas some natural proportion from soil minerals are thought to have been released very slowly. Therefore, little F released during the accident remained, based on the results of this study on the samples after two years of the accident. We could conclude that soil contaminated by external effects such as chemical accidents should be managed immediately, especially with F.

The Study on Acute.Subacute Toxicity and Anti-cancer Effect of H Herbal-acupuncture (H-약침(藥鍼)의 급성(急性).아급성(亞急性) 독성실험(毒性實驗) 및 항암효과(抗癌效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Tae-Hui;Kwon, Ki-Rok;Lee, Seon-Goo
    • Journal of Pharmacopuncture
    • /
    • v.5 no.2
    • /
    • pp.120-136
    • /
    • 2002
  • Objectives : The purpose of this study is to investigate Acute and Subacute Toxicity, and Anti-cancer Effect of H Herbal-acupuncture on mice and rats. Methods : Balb/c mice were injected intraperitoneally with H Herbal-acupuncture for $LD_{50}$ and acute toxicity test. Sprague-Dawley rats were experimented in the same way for subacute toxicity test. H Herbal-acupuncture was injected into abdomen of mice having S-180 cancer cell line. Result : 1. During the test, $LD_{50}$ could not be counted since there was no expired subjects. 2. In an acute toxicity test, the loss of motility and reflex action was observed, but weight increased in the treatment group, compared with those in the normal group (P<0.05). 3. In an acute toxicity test of serum biochemical values of mice, glucose increased in the treatment group II while total cholesterol was increased in the all treatment groups (P<0.05). 4. In a subacute toxicity test, a little loss of motility and reflex action was observed in the treatment group. Weight of mice in the treatment group decreased on the 28th day. 5. In a subacute toxicity test, liver weight was decreased but lung weight of mice increased in the all treatment groups (P<0.05). 6. As a result of measuring Complete Blood Count test (CBC) of rat, HCT was decreased in treatments even though it was not significant, compared with the normal group (P<0.05). 7. In a serum biochemical value test of subacute toxicity, total protein and albumin decreased in the all treatment groups. Creatinine, glucose, GOT increased in the treatment group I compared with the control group. Alkaline phos-phatase decreased in treatment II group, compared with the control group (P<0.05). 8. Median survival time that was measured in the rats treated with sarcoma-180 cancer cell Median decreased in the treatment group, compared with the control group (P<0.05). 9. Natural killer cell activity showed significant reduction at 100:1 and 10:1 E/T ratio while it increased at 50:1 E/T ratio. It is inferred that there was an error in the experiment (P<0.05). 10. In an interleukin-2 productivity test, even though it decreased in lung cancer, and increased in abdomen cancer, but it was only a small difference (P<0.005). 11. After injecting B16F10 cell into a capillary vessel of C57BL/6 mice and generating metastasized lung cancer, the lung was examined with the naked eye. It was not possible to see metastasized cancer in the all groups on the seventh day but the cancer was viewed on the fourteenth day. The number and volume of metastasized cancer in the treatment group enlarged in the treatment group, compared with the control group. Conclusion : According to the results, H herbal-acupuncture took no effects in cancer.

The Effect of Subjective Xerostomia and Salivary pH in Salivary Glands Stimulated by Laughter Therapy in Frail Elderly Women (웃음치료를 통한 침샘자극이 허약노인의 구강건조와 타액 pH에 미치는 효과)

  • Lim, Sun Young;Lee, Kyem Ju;Kim, Su Jin
    • Research in Community and Public Health Nursing
    • /
    • v.27 no.1
    • /
    • pp.72-80
    • /
    • 2016
  • Purpose: The purpose of this study was to identify the effect of subjective xerostomia and salivary pH in salivary glands stimulated by laughter therapy in frail elderly women. Methods: The research used a one-group pretest-posttest design. Data were collected from July 2, 2015 to September 30, 2015. A sample of 41 frail female elderly patients was recruited at A Nursing Home in K City, Korea. We measured xerostomia and salivary pH using a questionnaire and BCP test paper (pH 5.6~7.2). Laughter therapy was given once a week for four weeks (3 items). Data were analyzed through descriptive statistics, independent t-test, ANOVA, paired t-test and Cronbach's using the SPSS 18.0 program. Results: There were significant differences in salivary pH according to oral health (t=-2.06, p<.05). There were significant differences in xerostomia (t=4.41, p<.001) and salivary pH (t=-7.94, p<.001) after salivary glands stimulated by laughter therapy. Conclusion: Salivary glands stimulated by laughter therapy improved xerostomia and salivary pH of the frail elderly. Therefore, salivary glands stimulated by laughter therapy may be useful in promoting and maintaining oral health among the frail elderly in the rapidly increasing population of old people.

Comparison of EEC-4 Plate Test and Charm II Test in Residual drug Screening Methods on Meats (식육 중 잔류물질 스크리닝법인 EEC-4 Plate Test와 Charm II Test 비교)

  • Ham Hee-jin;Kim Doo-whan;Kweon Taek-boo;Lee Jung-hark
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.198-202
    • /
    • 2004
  • It was carried out to compare the relationship of EEC 4-plate test method and Charm II test method by HPLC. 46 only tetracyclines, 4 only sulfonamides, 4 sulfonamides+tetracyclines, one amphenicols+tetracyclines, and one amphenicols+sulfonarnides+tetracyclines, it was detected on 71 porks of EEC 4-plate positive or Charm II positive by HPLC. In case of sulfonamides and chloramphenicols, two test methods had related with each other, but had no relation in tetracyclines. Also, it was $10.5\%(6/57)$ tetracyclines, $81.8\%(9/11)$ chloramphenicols that were EEC 4 plate positive or Charm II positive, but not detectrd by HPLC. Consequently, EEC 4-plate test method and Charm II test method were suitable by screening test on antibiotics and sulfonamides etc.

The Study on the Wear-Corrosion Behavior of Al-Mg Alloy in the Coast (연안해안에서 Al-Mg 합금재 프로펠러의 마멸-부식거동에 관한 연구)

  • Park Hee-Ok;Lim Uh-Joh;Park Dong-Gi
    • Tribology and Lubricants
    • /
    • v.20 no.2
    • /
    • pp.97-101
    • /
    • 2004
  • This paper reports the studies on the wear-corrosion behavior of Al-Mg alloy in various pH environments. In various pH of sea water, corrosion and wear-corrosion loss of Al-Mg alloy were investigated. Also, the polarization test of Al-Mg alloy using potentiostat/galvanostat was carried out. And the rubbed surface of Al-Mg alloy using scanning electron micrographs after wear-corrosion test was examined in various pH values of sea water. The main results are as following : The polarization resistance of Al-Mg alloy in pH 4 solution is higer than that in pH 6.7 solution, and the corrosion current density in pH 4 is controlled than in pH 6.7 solution. The wear-corrosion loss of Al-Mg alloy with lowering pH becomes sensitive. As the oxide product of Al-Mg alloy appears granular structure and exholiation phenomenon, wear-corrosion loss of Al-Mg alloy increases.