• 제목/요약/키워드: pH influence

검색결과 1,810건 처리시간 0.029초

동방결절 활동전압에 대한 아데노신 효과 (Effects of Adenosine on the Action Potentials of Rabbit SA Nodal Cells)

  • 김기환;호원경
    • The Korean Journal of Physiology
    • /
    • 제18권1호
    • /
    • pp.19-35
    • /
    • 1984
  • Since the first report of Drury and $Szent-Gy{\ddot{o}}rgyi$ in 1929, the inhibitory influences of adenosine on the heart have repeatedly been described by many investigators. These studies have shown that adenosine and adenine nucleotides have overall depressant effects, similar to those of acetylcholine. Heart beats become slow and weak. It is also well known that adenosine is a potent endogenous coronary vasodilator. Many investigations on the working mechanisms of adenosine have been focused mainly on the effects of the coronary blood flow. However, the cellular mechanisms underlying the inhibitory action of adenosine on sinus node are not well understood yet. Thus, this study was undertaken to examine the behavior of rabbit SA node under influence of adenosine. In these series of experiments three kinds of preparations were used: whole atrial pair, left atrial strip, and isolated SA node preparations. The electrical activity of SA node was recorded with conventional glass microelectrodes 30 to 50 $M{\Omega}$. The preparations were superfused with bicarbonate-buffered Tyrode solution of pH 7.35 and aerated with a gas mixture of $3%\;CO_2-97%\;O_2$ at $35^{\circ}C$. In whole atrial pair, adenosine suppressed sinoatrial rhythm in a dose-dependent manner. Effect of adenosine on atrial rate appeared at the concentration of $10^{-5}M$ and was enhanced in parallel with the increase in adenosine concentration. Inhibitory action of adenosine on pacemaker activity was more prominent in the preparation pretreated with norepinephrine, which can steepen the slope of pacemaker potential by increasing permeability of $Ca^{+2}$. Calcium ions in perfusate slowly produced a marked change in sinoatrial rhythm. Elevation of the calcium concentration from 0.3 to 8 mM increased the atrial rate from 132 to 174 beats/min, but over 10 mM $Ca^{+2}$ decreased. The inhibitory effect of adenosine on sinoatrial rhythm developed very rapidly. Atrial rate was recovered promptly from the adenosine-induced suppression by the addition of norepinephrine, but extra $Ca^{+2}$ was less suitable to restore the suppression of atrial rate. Adenosine suppressed also atrial contractility in the same dosage range that restricted pacemaker activity, even in the reserpinized preparation. In isolated SA node preparation, spontaneous firing rate of SA node at $35^{\circ}C$(mean{\pm}SEM, n=16) was $154{\pm}3.3\;beats/min. The parameters of action potentials were: maximum diastolic potential(MDP), $-73{\pm}1.7\;mV: overshoot(OS), $9{\pm}1.4\;mV: slope of pacemaker potential(SPP), $94{\pm}3.0\;mV/sec. Adenosine suppressed the firing rate of SA node in a dose-dependent manner. This inhibitory effect appeared at the concentration of $10^{-6}M$ and was in parallel with the increase in adenosine concentration. Changes in action potential by adenosine were dose-dependent increase of MDP and decrease of SPP until $10^{-4}M$. Above this concentration, however, the amplitude of action potential decreased markedly due to the simultaneous decrease of both MDP and OS. All these effects of adenosine were not affected by pretreatment of atropine and propranolol. Lowering extra $Ca^{2+}$ irom 2 mM to 0.3 mM resulted in a marked decrease of OS and SPP, but almost no change of MDP. However, increase of perfusate $Ca^{2+}$ from 2 mM to 6 or 8 mM produced a prominent decrease of MDP and a slight increase of OS and SPP. Dipyridamole(DPM), which is known to block the adenosine transport across the cell membrane, definately potentiated the action of adenosine. The results of this experiment suggest that adenosine suppressed pacemaker activity and atrial contractility simultaneously and directly, by decreasing $Ca^{2+}-permeability$ of nodal and atrial cell membranes.

  • PDF

방사선조사된 패티용 분쇄우육의 가열전 품질특성 (Quality Properties of the Refrigerated or Frozen Irradiated Beef Patty)

  • 전기홍;오세욱;이남혁;김윤지;박기재;김영호
    • 육가공
    • /
    • 통권36호여름호
    • /
    • pp.72-86
    • /
    • 2009
  • 본 연구에서는 단체급식이나 외식용으로 주로 사용하고 있으나 미생물 오염에 쉽게 노출될 수 있는 패티용 분쇄 우육에 방사선조사기술을 적용하였을 때 나타나는 미생물 감균효과, 품질특성 및 관능품위에 미치는 영향을 살펴보았다. 방사선조사 직후의 냉장육 초기 미생물은 식품 첨가물에 관계없이 $10^{5}CFU/g$ 수준이었으나 3 kGy 선량의 방사선조사에 의하여 $10^{2}-10^{3}CFU/g$ 수준으로 감균되었으며, 7 kGy에서는 미생물이 검출되지 않았다. 반면에 $-20^{\circ}C$에서 90일 저장한 냉동육의 미생물은 $10^{3}-10^{4}CFU/g$ 수준으로 낮아졌고 3 kGy 이상의 조사선량에서 미생물이 검출되지 않았다. 분쇄우육 제조시 가공적성 또는 맛을 개선하기 위하여 사용되는 아질산염, 소금, 인산염 및 아스콜빈산과 같은 식품첨가물은 미생물의 방사선 감수성에 큰 영향을 주지 않는 것으로 나타났다. 분쇄우육의 보수력에 미치는 방사선조사의 영향은 크지 않았으며, 방사선조사와 관계없이 냉장 육에 비하여 냉동육의 보수력이 높았는데 pH 변화와 관계가 있는 것으로 생각되었다. 해동감량에 미치는 방사선조사의 영향은 보수력과 마찬가지로 방사선조사선량에 따라 유의적 차이를 나타내지 않았으나 소금과 인산염이 첨가된 시료구에서는 해동감량이 적게 나타났다. 냉장육의 경우 방사선조사선량이 증가할수록 TBARS 값이 증가하는 경향을 보였으나 첨가물이 함유된 시료구는 대조구보다 낮은 TBARS 값을 보였고, 냉동육은 냉동변성에 의한 육질의 물리적 특성 변화가 TBARS값에 일부 영향을 미치는 것으로 예상되었다. 적색도는 냉장육 대조구의 경우 방사선조사에 의하여 약간 증가하는 경향을 보였으나 식품첨가물이 첨가된 시료구에서는 3kGy에서 가장 높은 적색도를 보인 이후 7 kGy 이상에서 감소하는 경향을 보였다. 그러나 냉동육은 방사선조사 및 식품첨가물의 영향에 따른 뚜렷한 경향을 찾을 수 없었다. 한편, 냄새 및 색깔에 대한 관능특성을 보면 방사선조사에 의하여 불쾌취가 높았으나 이러한 불쾌취는 아스콜빈산 첨가에 의하여 일정부분 상쇄되는 것으로 나타났다. 색깔의 경우 전반적으로 시료구에 관계없이 3 kGy 방사선조사에서 관능적으로 양호하였으며 이는 적색도와 유사한 결과를 보였다. 특히, 아스콜빈산이 함유된 시료구에서 색깔 및 냄새에 대하여 양호한 점수가 나온 결과에서 방사선조사된 고기의 냄새와 색깔에 미치는 아스콜빈산의 영향에 대한 추가 연구가 필요할 것으로 생각되었다.

  • PDF

우리나라 재배지역별 야콘 생산성 및 기능성 프락토올리고당 평가 (Environmental Evaluation of the Productivity and Functional Fructo-oligosaccharides of Yacon Cultivated in Various Regions of Korea)

  • 김수정;손황배;홍수영;남정환;장동칠;김기덕;서종택;구본철;김율호
    • 한국작물학회지
    • /
    • 제62권3호
    • /
    • pp.249-258
    • /
    • 2017
  • 본 연구는 남미 안데스 원산인 야콘을 대상으로 국내 주요 재배지의 적응성을 평가하고자 2010년부터 2013년까지 4년동안 8 지역을 대상으로 토양환경, 기상환경, 생육 및 수량 특성을 비교하였다. 주요 결과는 아래와 같다. 1. 야콘 주요 재배 8지역의 토양 pH 범위는 5.3~6.9로써 약산성이었고, EC는 0.3~0.9 dS/m의 범위를 나타내어 염류집적이 거의 없는 야콘 생육에 적합한 토성이었다. 2. 야콘의 덩이뿌리 최성기~증가기(9~10월)의 최고온도는 진부, 봉화, 철원, 강릉 지역이 $17.5{\sim}24.6^{\circ}C$를 나타내어 덩이뿌리 생육에 적정온도 범위를 보였으나, 대관령의 온도는 $15.0{\sim}20.0^{\circ}C$로 적정온도($18{\sim}25^{\circ}C$)보다 낮았으며, 순천, 옥천, 여주는 $20.0{\sim}27.1^{\circ}C$로 적정온도보다 높았다. 3. 야콘의 생산성을 지역별로 비교하였을 때, 진부지역이 총수량과 상품수량이 각각 4,065, 3,196 kg/10a로 다른 지역보다 가장 높았으며, 그 다음으로 봉화, 철원 순이었다. 4. 야콘 덩이뿌리의 당함량을 분석한 결과, 프럭토스 0.11~0.20%, 글루코스 0.11~0.37%, 수크로스 0.39~0.68%, 환원당 0.07~0.37%, 프락토올리고당이 7.03~9.62%이 함유되어 있었다. 진부지역이 기능성 물질인 프락토올리고당 함량이 가장 높았다. 5. 야콘의 국내 적응성을 평가한 결과, 생육온도인 $18{\sim}25^{\circ}C$인 준고랭지 지역(500-560 m)인 진부 및 봉화에서 가장 안정적인 생산성을 나타내어 기상환경이 야콘의 덩이뿌리 생육에 가장 큰 영향을 미치는 것으로 구명되었다.

영산강 및 섬진강 수계 중 농약 분포 조사 (Monitoring of Pesticides in the Yeongsan and Seomjin River Basin)

  • 이영준;최정희;김상돈;정희정;이형진;심재한
    • 한국환경농학회지
    • /
    • 제34권4호
    • /
    • pp.274-281
    • /
    • 2015
  • 영산강과 섬진강의 지천을 중심으로 총 22개 지점에서 4회에 걸쳐 농약(aldicarb, carbaryl, carbofuran, chlorpyrifos, 2,4-D, MCPA, methomyl, metolachlor, molinate)의 실태조사를 수행하였다. 하천수 시료에서 농약을 추출하기 위해 Oasis HLB 카트리지를 사용하였고 LC/ MS/MS를 이용하여 분석하였다. 시험법은 matrix-matched 내부표준검량곡선과 방법검출한계, 정량한계, 정확도, 정밀도, 회수율 등으로 정도관리를 수행하였다. 각 화합물의 방법검출한계는 모든 화합물이 국립환경과학원에서 제안하는 GV/10을 만족하였다. 모든 화합물의 상관계수(r2)는 0.9965- 0.9999로써 직선성이 매우 높았고 정확도와 정밀도는 각각 89.4-113.6%와 3.1-14.0%로써 매우 양호함을 알 수 있었으며 평균 회수율은 90.8-106.2%로 매우 우수하였다. Aldicarb를 제외한 모든 성분이 검출되었고, 특히 carbofuran과 metolachlor의 검출농도와 빈도가 높았는데 이들의 광범위한 적용 범위에 따른 많은 사용량에 기인한 것으로 판단되었다. 2,4-D와 MCPA는 1(5월), 2차(7월) 시료에서만 검출되었는데 이는 두 농약의 사용 적기와 일치하였다. Methomyl과 molinate는 사용 금지된 농약이었으나 일부 지역에서 검출되었고 이는 두 농약이 불법적으로 사용되었거나 과거에 사용되어 수계로 유입, 저질에 흡착된 일부분이 지금까지 용출되어 검출되었을 것으로 판단되었다. 영산강 및 섬진강 수계의 많은 하천수 시료에서 농약이 검출되었고 그 원인이 영농활동 중 농약의 사용이라고 단정할 수 없으나, 영산강과 섬진강 수계 인근의 주된 산업활동이 농업활동이고 농약의 주된 사용이 영농활동에 이루어지며 검출된 농약이 농작물에 대한 약제의 사용 시기와 부합하는 것을 미루어 보아 영산강과 섬진강 유역 농경지에서 사용된 농약이 수계로 유입되어 비점오염원으로 작용하는 것으로 판단되었다. 따라서 수생태계 보존을 위하여 농약에 대한 수질기준 설정이 절실히 요구되었고, 이를 위해 보다 많은 실태조사 결과의 축적과 꾸준한 연구 수행이 필요한 것으로 판단되었다.

방사선조사된 패티용 분쇄우육의 가열전 품질특성 (Quality Properties of the Refrigerated or Frozen Irradiated Beef Patty)

  • 전기홍;오세욱;이남혁;김윤지;박기재;김영호
    • 한국축산식품학회지
    • /
    • 제28권4호
    • /
    • pp.437-444
    • /
    • 2008
  • 본 연구에서는 단체급식이나 외식용으로 주로 사용하고 있으나 미생물 오염에 쉽게 노출될 수 있는 패티용 분쇄우육에 방사선조사기술을 적용하였을 때 나타나는 미생물 감균효과, 품질특성 및 관능품위에 미치는 영향을 살펴보았다. 방사선조사 직후의 냉장육 초기 미생물은 식품첨가물에 관계없이 $10^5$ CFU/g수준이었으나 3 kGy 선량의 방사선조사에 의하여 $10^2-10^3$ CFU/g 수준으로 감균되었으며, 7 kGy에서는 미생물이 검출되지 않았다. 반면에 $-20^{\circ}C$에서 90일 저장한 냉동육의 미생물은 $10^3-10^4$ CFU/g 수준으로 낮아졌고 3 kGy이상의 조사선량에서 미생물이 검출되지 않았다. 분쇄우육 제조시 가공적성 또는 맛을 개선하기 위하여 사용되는 아질산염, 소금, 인산염 및 아스콜빈산과 같은 식품첨가물은 미생물의 방사선 감수성에 큰 영향을 주지 않는 것으로 나타났다. 분쇄우육의 보수력에 미치는 방사선조사의 영향은 크지 않았으며, 방사선조사와 관계없이 냉장육에 비하여 냉동육의 보수력이 높았는데 pH 변화와 관계가 있는 것으로 생각되었다. 해동감량에 미치는 방사선조사의 영향은 보수력과 마찬가지로 방사선조사선량에 따라 유의적 차이를 나타내지 않았으나 소금과 인산염이 첨가된 시료구에서는 해동감량이 적게 나타났다. 냉장육의 경우 방사선조사선량이 증가할수록 TBARS값이 증가하는 경향을 보였으나 첨가물이 함유된 시료구는 대조구보다 낮은 TBARS 값을 보였고, 냉동육은 냉동변성에 의한 육질의 물리적 특성 변화가 TBARS 간에 일부 영향을 미치는 것으로 예상되었다. 적색도는 냉장육 대조구의 경우 방사선조사에 의하여 약간 증가하는 경향을 보였으나 식품첨가물이 첨가된 시료구에서는 3 kGy에서 가장 높은 적색도를 보인 이후 7 kGy 이상에서 감소하는 경향을 보였다. 그러나 냉동육은 방사선조사 및 식품첨가물의 영향에 따른 뚜렷한 경향을 찾을 수 없었다. 한편, 냄새 및 색깔에 대한 관능특성을 보면 방사선조사에 의하여 불쾌취가 높았으나 이러한 불쾌취는 아스콜빈산 첨가에 의하여 일정부분 상쇄되는 것으로 나타났다. 색깔의 경우 전반적으로 시료구에 관계없이 3 kGy 방사선조사에서 관능적으로 양호하였으며 이는 적색도와 유사한 결과를 보였다. 특히, 아스콜빈산이 함유된 시료구에서 색깔 및 냄새에 대하여 양호한 점수가 나온 결과에서 방사선조사된 고기의 냄새와 색깔에 미치는 아스콜빈산의 영향에 대한 추가 연구가 필요할 것으로 생각되었다.

감압 텀블링 해동이 돈육의 품질 특성에 미치는 영향 (Influence of low-pressure tumbling on the quality characteristics of thawed pork)

  • 홍원호;김정;곽유정;천지연
    • 한국식품저장유통학회지
    • /
    • 제30권1호
    • /
    • pp.88-97
    • /
    • 2023
  • 본 연구는 다양한 해동 조건에서 해동된 돈육의 품질 특성을 비교 분석하여 식육 가공 산업에서 필수적으로 사용되는 해동 공정 개선 및 새로운 해동 설비를 구축하기 위한 기초 자료를 마련하고자 수행되었다. 냉동육(돈육 전지)을 실온 해동(room temp-thawing: 20℃, under air), 저온냉장 해동(low temp-thawing: 4℃ refrigerator, under air), 침수 해동(water thawing: 20℃, water in a vacuum bag), 전자레인지 해동(microwave thawing: microwave-thawing, 260 W), 감압 텀블링 해동(low pressure-tumbling: 20℃, 0.015 bar, tumbling)으로 각각 해동하여 이에 따른 해동 및 품질 특성을 분석하였다. 냉동 돈육의 내부중심온도가 -6℃에서 0℃에 도달하는 시간을 총 해동 시간으로 했을 때, 감압 텀블링 해동의 해동 시간이 20분으로 가장 짧았고, 냉장 해동이 840분으로 가장 긴 것으로 확인되었다. 해동으로 인한 냉동 돈육의 드립 손실(%)은 감압 텀블링 해동에서 0.15%로 가장 낮은 값을 보였으며, 침수 해동에서 가장 많은 드립(1.16%)이 발생되었다. 해동 시간에 큰 차이를 보임에도 불구하고, 해동 돈육의 pH는 해동 조건에 따라 유의적인 차이를 보이지 않은 반면, 해동 육의 총균수와 대장균군 모두 감압 텀블링 해동에서 가장 낮았다. 해동 돈육의 색도(L, a, b)는 해동 방법에 따라 유의적인 차이를 보였으나, 육안으로는 두드러진 차이를 관찰하기 어려웠다. 해동 돈육의 보수력은 감압 텀블러 해동(94.5%)과 침수 해동(94.2%)이 유의적인 차이 없이 높은 보수력을 보였으며, 다음으로 실온 해동(92.2%), 저온냉장 해동(89.4%), 전자레인지 해동(87.2%) 순으로 유의적으로 보수력이 감소하였다. 본 실험은 해동 방법에 따라 냉동 돈육의 품질 특성 및 가공 효율성이 크게 달라지는 것을 보여주었으며, 특히 재래식 해동법에 비해 감압 텀블링 해동 방식이 드립 감량율, 보수력, 미생물 생육도, 해동 속도 등을 비교할 때 가장 우수한 해동 방법이 될 것으로 보인다. 본 연구 결과는 향후 텀블링 방식의 해동기 개발 및 산업화를 위한 기초 자료로 활용할 수 있을 것이다.

일부 초등학생의 대표적 신체활동의 에너지소비량 측정 및 에너지소비량과 체중과의 상관성 분석 (Energy expenditure measurement of various physical activity and correlation analysis of body weight and energy expenditure in elementary school children)

  • 김재희;손희령;최정숙;김은경
    • Journal of Nutrition and Health
    • /
    • 제48권2호
    • /
    • pp.180-191
    • /
    • 2015
  • 본 연구는 만 9~12세의 초등학생 총 20명(남아 11명, 여아 9명)을 대상으로 18가지의 일상생활에서의 대표적인 신체활동에 따른 에너지소비량을 측정하여, 아동의 일상생활에서 수행하는 신체활동에 따른 에너지소비량을 평가하고, 체중이 METs 값에 미치는 영향을 분석해보았다. 1. 연구대상자의 평균연령은 $10.4{\pm}0.6$세였으며, 평균 신장 및 체중은 $145.1{\pm}8.5cm$$43.6{\pm}10.3kg$ 이었다. 대상자의 허리둘레는 남아와 여아 각각 $73.6{\pm}9.6cm$$63.5{\pm}7.1cm$로 남녀 간의 유의한 차이를 보였다 (p < 0.05). 2. 연구대상자의 휴식 시 산소소비량 ($VO_2$), 에너지소비량 및 METs 값은 각각 $5.41{\pm}0.89mL/kg/min$, $1.44{\pm}0.17kcal/kg/h$$1.5{\pm}0.4METs$로 나타났다. 3. 18가지의 신체활동에 따른 METs 값은 앉아서 숙제하기 및 책읽기 ($1.6{\pm}0.3METs$), 앉아서 비디오 혹은 핸드폰으로 게임하기 ($1.6{\pm}0.5METs$), 앉아서 텔레비전 시청하기 ($1.7{\pm}0.5METs$), 서서 비디오 혹은 핸드폰으로 게임하기 ($1.9{\pm}0.6METs$), 빗자루로 방 쓸기 ($2.7{\pm}1.1METs$) 및 보드게임 ($2.8{\pm}2.2METs$)이 가벼운 신체활동에 속하였으며, 진공청소기로 청소하기 ($3.0{\pm}0.2METs$), 피구 ($3.6{\pm}0.9METs$), 삽질하기 ($3.8{\pm}0.4METs$), 계단오르내리기 ($3.8{\pm}1.3METs$), 농구 슛팅 ($4.4{\pm}.1.5METs$), 줄넘기 ($4.6{\pm}2.6METs$), 음악에 맞추어 스트레칭 ($4.7{\pm}2.3METs$), 천천히 걷기 ($4.8{\pm}2.6METs$) 및 배드민턴 ($4.8{\pm}1.0METs$)의 활동이 중간강도의 신체활동에 속하였다. 빨리 걷기 및 달리기는 각각 $6.6{\pm}1.7$$6.7{\pm}1.5METs$로 6.0 METs 이상의 고강도 신체활동에 속하는 것으로 나타났다. 4. 본 연구결과를 성인 METs 값 및 기존에 보고된 아동 METs 값과 비교하기 위하여 Bland-Altman 분석을 실시한 결과 각각 mean difference $0.18{\pm}1.57$, upper and lower limit of agreement 0.99 and -0.62 및 mean difference $0.28{\pm}1.49$, upper and lower limit of agreement 1.05 and -0.48로 나타났으며, ICC (interclass correlation coefficient)를 통한 일치도 분석결과는 각각 0.815 및 0.837로 성인의 METs 값보다는 기존에 보고된 아동 METs 값과의 일치도가 더 높은 것으로 나타났다. 5. 체중이 신체활동에 따른 에너지소비량에 미치는 영향을 살펴본 결과, 앉아서 게임하기 (METs 1.6), 계단오르내리기 (METs 3.8), 천천히 걷기 (METs 4.8) 및 달리기 (METs 6.6)에서 $R^2$값이 각각 0.116, 0.176, 0.246 및 0.455로 증가하였으며, 활동 강도가 높을수록 체중이 METs 값에 대한 설명력이 증가함을 알 수 있었다. 신체활동은 건강증진 및 질병예방에 중요한 역할을 하며, 특히, 일상생활에서 신체활동을 증진시키는 것은 많은 질병에 있어 최선의 예방책 가운데 필수적인 요소이다. 이러한 면에서 영양 및 운동처방의 목표에 정확하게 도달하기 위해서는 에너지소비량, 특히, 일상생활에서의 신체활동이 정확하게 평가되어져야한다. 결론적으로, 신체활동에 따른 에너지소비량을 평가하기 위해 성인의 데이터가 존재할지라도 아동들의 일상적인 활동에 대한 에너지 cost 자료는 부족한 실정이다. 이에 본 연구는 초등학생의 신체활동에 따른 에너지소비량에 대한 데이터를 직접 측정하여 평가하였다는데 큰 의의가 있으며, 추후 연구에서는 더 넓은 범위의 그룹 및 다양한 연령대의 아동을 대상으로 한 연구가 이루어져야 할 것이다.

인공광 식물공장에서 수경배양액 및 광질 조절이 상추 실생묘 생장에 미치는 영향 (Hydroponic Nutrient Solution and Light Quality Influence on Lettuce (Lactuca sativa L.) Growth from the Artificial Light Type of Plant Factory System)

  • 허정욱;박경훈;홍승길;이재수;백정현
    • 한국환경농학회지
    • /
    • 제38권4호
    • /
    • pp.225-236
    • /
    • 2019
  • 인공광 식물공장에서는 작물을 생산하기 위하여 일반적으로 화학비료 유래 무기성분을 포함하는 배양액을 시용하여 수경재배한다. 본 연구에서는 광질이 상이한 식물공장에서 관행의 무기배양액 일부 또는 전량을 유기배양액으로 대체할 수 있는 폐기 농업부산물 유래 유기배양액을 시용하여 수경재배하고 작물의 생장에 미치는 영향을 검토하였다. 청색, 적색 및 백색 LED를 1:2:1의 비율로 혼합한 혼합LED 및 관행의 형광등 조사 조건에서 적치마와 청치마 상추 실생묘를 35일간 수경재배한 결과, 적치마와 청치마 상추의 생체중 및 전개엽수 증가는 형광등을 조사한 Y구에서 통계적으로 유의하게 증가하였다. 그러나 유·무기 혼합배양액 처리구인 YK 및 YTJ에서는 오히려 혼합LED 조사구에서 증가하였다. 유기배양액 단용 또는 유·무기 혼합배양액 처리시 엽내 SPAD치는 두 실생묘 모두 Y구와 유사하거나 증가하는 경향을 나타내었다. 관행의 무기배양액인 Y구에서 배양액내 구성성분 중 가장 많은 양을 차지하고 있는 무기성분인 NO3-N은 재배 개시일에 약 97 mg/L으로, 적치마와 청치마 상추 실생묘에서 모두 재배기간이 경과함에 따라 감소하는 경향을 보였다. 적치마의 경우 재배종료시 각 처리구별 NO3-N 농도는 형광등 조사시 약 29 mg/L, 혼합LED 조사시 24 mg/L였으며, 청치마의 경우 형광등 조사시 약 26 mg/L, 혼합LED 조사시 47 mg/L로, 초기 투입량 대비 25~48% 정도의 양이 재배종료시까지 흡수되지 않고 남아 있었다. 재배개시일 NH3-N 농도는 Y구3-N 잔여량은 약 13%로 최대값을 나타내었다. 관행의 무기배양액내 질산태질소는 작물체에 흡수되어 생체중, 엽수 증가와 같은 지상부 생장을 좌우하는 주요 성분이지만 재배종료시까지 전량이 흡수되지 않고 남아 있는 것으로 보아 상추 수경재배시 배양액내 질산태질소의 초기 투입량을 조절할 필요성이 대두되었다. 연구결과 농업부산물 유래 유기배양액을 활용하여 적치마와 청치마 상추를 수경재배할 경우 유기배양액 단용보다 유·무기 혼합배양액 시용으로 유기배양액내 부족한 질소 성분을 무기질소로 보충할 수 있어 무기성분 사용량 저감이 기대된다. 또한 상추 실생묘의 양적생장 추이와 달리 엽내 색소합성이 관행 무기배양액보다 특정 유기배양액 단용 또는 혼용에 의해 유의하게 증가하는 것으로 보아 작물체내 물질합성량, 유기배양액 사용기간 및 재이용 등 유기배양액의 화학적 특성 변화에 대한 연구가 필요할 것으로 판단된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF