• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.024 seconds

pH equation model of RFID-pH sensor using fermented foods (RFID-pH 센서를 이용한 발효식품의 pH 모델식)

  • Lee, Chang Won;Kim, Joo Woong;Son, Dong Sul;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.849-852
    • /
    • 2013
  • These fermented food has been increased interest to people's health in recent years. Factors which have taste, storability and trophism of fermented food is affected food of material, temperature, humidity and pH. But fermented food has yet not been established of model equation for the change in pH. If they that seller and consumer can know the status and quality, customer could increase credibility and consumption-oriented about fermented foods. In this paper, we obtain model equation through measured PH of fermented foods. So, model equation is offered platform about maturity of fermented foods. In order to confirm the usefulness of the proposed model equation, we tested the change in PH about a kimchi and a rice wine which is fermented food of Korea representative.

  • PDF

Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients (수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발)

  • Kim, G.;Lee, S.B.;Chang, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.5
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement (잔류염소 측정용 전기화학센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

Implementation of Multichannel LAPS and Measurement System for Detection of the pH Variation Using an Implemented Device. (다채널 LAPS 제작 및 이를 이용한 pH 변화량 검출 시스템 구현)

  • Bae, Sang-Kon;Park, Il-Yong;Park, Young-Sik;Jang, Soo-Won;Lee, Sung-Ha;Kang, Shin-Won;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.239-249
    • /
    • 2001
  • LAPS is a device which is dependent on the bias potential between a pH sensitivity and alternating photocurrent. We implemented the multichannel LAPS device and the detection system which was able to effectively measure the sensor's output by a synchronized detection circuit and multiple methods. The implemented LAPS was structured the multiple sensing sites for analyzing a various components simultaneously. And the system included a time-division method using one pre-amplifier being able to detect the multichannel pH concentration preserving a high S/N ratio and a control part. System hardware consists of a pre-amplifier, digital unit and sensor unit, and software consists of a system program and PC program. As results, we verified the successful operations of system including an implemented pre-amplifier and signal processing units.

  • PDF

A New Strategy for Determining Optimum pH of Isozymes

  • Yoon, Kil-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.7
    • /
    • pp.997-1002
    • /
    • 2004
  • A hydrogenperoxide sensor containing peroxidase extracted from horseradish was constructed and pH effect on its sensing ability was investigated. Current profiles of the biosensor with pH and the electrophoretic analysis showed that horseradish peroxidase consists of two isozymes. Assuming that it is a hypothetical twoisozyme mixture, the current profiles were deconvoluted into two Gaussians. Application of the new Michaelis-Menten equation connoting pH concept to this system enabled to find all the related dissociation constants of the isozyme-substrates and the isozyme-proton complexes and to determine pHs for the maximal isozyme activities.

Development and Performance Evaluation of Multiple Sensor for Groundwater Quality Monitoring and Remote Control System using IoT (IoT기반 지하수 수질모니터링을 위한 다중센서모듈 개발 및 성능평가)

  • Chang, Hyunjin;Moon, Boram;Yoon, Seunggyun;Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1957-1963
    • /
    • 2017
  • This paper has proposed a new-type groundwater auto-monitoring system based on Multi-Sensor Device. The system adopted Multi-Sensor Device as host computer of data acquisition, used Windows Mobile which was prevalent operation system of Multi-Sensor Device. It adopted serial port CAN and RS485 as the communication interface between goundwater sensor Device and monitor host machine and utilized serial-linked multi-sensor design to measure effectively according to the depth of groundwater. We present a design for a groundwater monitoring system based on a network of wirelessly linked sensors. The proposed solution will enable groundwater researchers and decision makers to have quick access to the groundwater data with less effort and cost. Though our design is initially meant for groundwater monitoring, it can be easily adapted to other fields of environmental monitoring.

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.

Fabrication and Characteristics of ISFET Urea Sensor Using Polyurethane (폴리우레탄을 이용한 ISFET 요소센서의 제작 및 특성)

  • Choi, Sung-Moon;Sohn, Byung-Ki;Kim, Ui-Rak
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.41-48
    • /
    • 1993
  • An ISFET urea sensor was fabricated by immobilizing the urease using polyurethane on the $H^{+}$ sensing $Si_{3}N_{4}$ thin film of pH-ISFET. The sensor could determine the urea concentration $1{\sim}50$ mg/dl with fast response of $3{\sim}5$ min. and good repeatability. For its application to clinical analysis, the results of the urea measurements in blood plasma using ISFET urea sensor were compared with these of conventional Urease-Indophenol method.

  • PDF