• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.038 seconds

Spectrofluorimetric Determination of Pb ion in Aqueous Media Using an Optical Sensor (광센서를 이용한 수용액 중 납이온의 형광분광법적 정량)

  • Lee, Sang Hak;Seo, Hyo Suk
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.407-411
    • /
    • 2002
  • A method to determine lead ion in aqueous media using an optical sensor loaded on a fluorescent optode membrane incoporating a metal ion-selective ionophore, a proton-selective chromoionophore and lipophilic anionic sites has been studied. The effects of pH and thickness of membrane on the fluorescence intensity were investigated. The effects of foreign ions such as $Na^+$, $K^+$, $Mn^{2+}$ and $Zn^{2+}$ on the determination of lead ion were also studied. The linear range in the calibration curve for the determination of lead ion was found to be 5.0${\times}10^-7$ to 5.0${\times}$$10^-3$M and the correlation coefficient in this range was -0.99107 under the optimal experimental conditions. The relative standard deviation of the blank signals was 3.0% and the detection limit of lead ion was 5.0${\times}$$10^-9$M.

Fabrication of Lipid Sensor Utilizing Photosensitive Water Soluble Polymer (감광성 수용성 고분자를 이용한 Lipid 센서의 제조)

  • Park, Lee-Soon;Kim, Gi-Hyeon;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.35-40
    • /
    • 1993
  • A FET(field effect transistor) type lipid sensor was fabricated uy immobilizing lipase enzyme on the gate of pH-ISFET($SiO_{2}/Si_{3}N_{4}$). A water soluble polymer, polyvinyl alcohol(PVA) was modified with 1-methyl-4-(formyl-styryl) pyridinium methosulfate(SbQ) to give a photosensitive membrane(PVA-SbQ) in which lipase was immobilized. The optimum photolithographic conditions were ; spin coating speed $5,000{\sim}6,000$ rpm. UV exposure time $20{\sim}30$ seconds, developing time in water $30{\sim}40$ seconds, and vacuum drying time 45 min. at room temperature with the suspension containing PVA-SbQ aqueous solution(SbQ 1mol%, 10 wt %) $200{\mu}L$, bovine serum albumin (BSA) 7.5 mg, and lipase 10 mg. The lipid sensor showed good linear calibration curve in the range of $10{\sim}100$ mM triacetin as a lipid sample.

  • PDF

Fabrication of Capacitive-Type Humidity Sensor with Poly(p-phenylene ether sulfone) (폴리(페닐렌에테르설폰)을 이용한 용량형 습도센서의 제조)

  • Cho, Jae-Ick;Choi, Kyoon;Kim, Chang-Jung;Kim, Byung-Ik;Park, Sueng-Hyun;Bang, Gi-Suk
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.207-209
    • /
    • 2006
  • We fabricated a capacitive-type humidity sensor using poly (p-phenylene ether sulfone: PES) as a humidity sensitive layer. The PES was dissolved in m-cresol $(CH_3C_6H_4OH)$ and spin-coated on ITO-coated glass substrate. Gold was deposited by sputtering as a water-permeable upper electrode. The capacitance of the sensor was inversely proportional to sensing film thicknesses and showed an excellent linearity of less than 1% in the humidity range of 20 to 90%. The sensor haying a $1.4{\mu}m$ sensing layer showed a hysteresis of 1.3% and a good sensitivity of 1.14 at 20 kHz.

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

Highly Sensitive and Selective Ethanol Sensors Using Magnesium doped Indium Oxide Hollow Spheres

  • Jo, Young-Moo;Lee, Chul-Soon;Wang, Rui;Park, Joon-Shik;Lee, Jong-Heun
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.4
    • /
    • pp.303-307
    • /
    • 2017
  • Pure $In_2O_3$, 0.5 and 1.0 wt% Mg doped $In_2O_3$ hollow spheres were synthesized by ultrasonic spray pyrolysis of a solution containing In-, Mg-nitrate and sucrose and their gas sensing characteristics to 5 ppm $C_2H_5OH$, p-xylene, toluene, and HCHO were measured at 250, 300 and $350^{\circ}C$. Although the addition of Mg decreases the specific surface area and the volume of meso-pores, the gas response (resistance ratio) of the 0.5 wt% Mg doped $In_2O_3$ hollow spheres to 5 ppm $C_2H_5OH$ at $350^{\circ}C$ (69.4) was significantly higher than that of the pure $In_2O_3$ hollow spheres (24.4). In addition, the Mg doped $In_2O_3$ hollow spheres showed the highest selectivity to $C_2H_5OH$. This was attributed to the dehydrogenation of $C_2H_5OH$ assisted by basic MgO into reactive $CH_3CHO$ and $H_2$.

Membrane Topology of Helix 0 of the Epsin N-terminal Homology Domain

  • Kweon, Dae-Hyuk;Shin, Yeon-Kyun;Shin, Jae Yoon;Lee, Jong-Hwa;Lee, Jung-Bok;Seo, Jin-Ho;Kim, Yong Sung
    • Molecules and Cells
    • /
    • v.21 no.3
    • /
    • pp.428-435
    • /
    • 2006
  • Specific interaction of the epsin N-terminal homology(ENTH) domain with the plasma membrane appears to bridge other related proteins to the specific regions of the membrane that are invaginated to form endocytic vesicles. An additional $\alpha$-helix, referred to as helix 0 (H0), is formed in the presence of the soluble ligand inositol-1,4,5-trisphosphate [$Ins(1,4,5)P_3$] at the N terminus of the ENTH domain (amino acid residues 3-15). The ENTH domain alone and full-length epsin cause tubulation of liposomes made of brain lipids. Thus, it is believed that H0 is membrane-inserted when it is coordinated with the phospholipid phosphatidylinositol-4,5-bisphosphate [$PtdIns(4,5)P_2$], resulting in membrane deformation as well as recruitment of accessory factors to the membrane. However, formation of H0 in a real biological membrane has not been demonstrated. In the present study, the membrane structure of H0 was determined by measurement of electron paramagnetic resonance (EPR) nitroxide accessibility. H0 was located at the phosphate head-group region of the membrane. Moreover, EPR line-shape analysis indicated that no pre-formed H0-like structure were present on normal acidic membranes. $PtdIns(4,5)P_2$ was necessary and sufficient for interaction of the H0 region with the membrane. H0 was stable only in the membrane. In conclusion, the H0 region of the ENTH domain has an intrinsic ability to form H0 in a $PtdIns(4,5)P_2$-containing membrane, perhaps functioning as a sensor of membrane patches enriched with $PtdIns(4,5)P_2$ that will initiate curvature to form endocytic vesicles.

Green Synthesis of Platinum Nanoparticles by Electroreduction of a K2PtCl6 Solid-State Precursor and Its Electrocatalytic Effects on H2O2 Reduction

  • Kim, Kyung Tae;Jin, Sung-Ho;Chang, Seung-Cheol;Park, Deog-Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3835-3839
    • /
    • 2013
  • A new synthesis route for Pt nanoparticles by direct electrochemical reduction of a solid-state Pt ion precursor ($K_2PtCl_6$) is demonstrated. Solid $K_2PtCl_6$-supported polyethyleneimine (PEI) coatings on the surface of glassy carbon electrode were prepared by simple mixing of solid $K_2PtCl_6$ into a 1.0% PEI solution. The potential cycling or a constant potential in a PBS (pH 7.4) medium were applied to reduce the solid $K_2PtCl_6$ precursor. The reduction of Pt(IV) began at around -0.2 V and the reduction potential was ca. -0.4 V. A steady state current was achieved after 10 potential cycling scans, indicating that continuous formation of Pt nanoparticles by electrochemical reduction occurred for up to 10 cycles. After applying the reduction potential of -0.6 V for 300 s, Pt nanoparticles with diameters ranging from $0.02-0.5{\mu}m$ were observed, with an even distribution over the entire glassy carbon electrode surface. Characteristics of the Pt nanoparticles, including their performance in electrochemical reduction of $H_2O_2$ are examined. A distinct reduction peak observed at about -0.20 V was due to the electrocatalytic reduction of $H_2O_2$ by Pt nanoparticles. From the calibration plot, the linear range for $H_2O_2$ detection was 0.1-2.0 mM and the detection limit for $H_2O_2$ was found to be 0.05 mM.