• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.032 seconds

Salphen H2 as a Neutral Carrier for the Uranyl Ion-Selective PVC Membrane Sensor

  • Kim, Dong-Wan;Park, Kyeong-Won;Yang, Mi-Hyi;Kim, Jin-eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.899-902
    • /
    • 2006
  • The complexation of N,N'-4,5-(ethylenedioxy)benzenebis(salicylideneimine), (salphen$H_2$) with uranyl ion was studied in acetonitrile solution spectrophtometrically, and the formation constant of the resulting 1 : 1 complex was evaluated. The salphen$H_2$ ligand was used as an ionophore in plasticized poly(vinyl chloride) (PVC) matrix membrane sensor for uranyl ion. The prepared sensors exhibited a near Nernstian response, 28.0-30.9 mV/decade for uranyl ion over the concentration range $1.0\;{\times}\;10^{-2}$ to $1.0\;{\times}\;10^{-6}$M with a limit of detection of $3.2\;{\times}\;10^{-7}$ M. The proposed electrode could be used at a working pH range of 1.5 - 4.0.

A Study on the Failure Detection and Validation of Pressurizer Level Signal in Nuclear Power Plant (원전 가압기수위신호 고장검출 및 검증에 관한연구)

  • Oh, S.H.;Kim, D.I.;Zoo, O.P.;Chung, Y.H.;Lim, C.H.;Yun, W.Y.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.175-177
    • /
    • 1995
  • The sensor signal validation and failure detection system must be able to detect, isolate, and identify sensor degradation as well as provide a reconstruction of the measurements. In this study, this is accomplished by combining the neural network, the Generalized Consistency Checking(GCC), and the Sequential Probability Ratio Test(SPRT) method in a decision estimator module. The GCC method is a computationally efficient system for redundant sensors, while the SPRT provides the ability to make decisions based on the degradation history of a sensor. The methodology is also extended to the detection of noise degradation. The acceptability of the proposed method is demonstration by using the simulation data in safety injection accident of nuclear power plants. The results show that the signal validation and sensor failure detection system is able to detect and isolate a bias failure and noise type failures under transient conditions. And also, the system is able to provide the validated signal by reconstructing the measurement signals in the failure conditions considered.

  • PDF

Freshness Monitoring of Raw Salmon Filet Using a Colorimetric Sensor that is Sensitive to Volatile Nitrogen Compounds (휘발성 질소화합물 감응형 색변환 센서를 활용한 연어 신선도 모니터링)

  • Kim, Jae Man;Lee, Hyeonji;Hyun, Jung-Ho;Park, Joon-Shik;Kim, Yong Shin
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.93-99
    • /
    • 2020
  • A colorimetric paper sensor was used to detect volatile nitrogen-containing compounds emitted from spoiled salmon filets to determine their freshness. The sensing mechanism was based on acid-base reactions between acidic pH-indicating dyes and basic volatile ammonia and amines. A sensing layer was simply fabricated by drop-casting a dye solution of bromocresol green (BCG) on a polyvinylidene fluoride substrate, and its color-change response was enhanced by optimizing the amounts of additive chemicals, such as polyethylene glycol, p-toluene sulfonic acid, and graphene oxide in the dye solution. To avoid the adverse effects of water vapor, both faces of the sensing layer were enclosed by using a polyethylene terephthalate film and a gas-permeable microporous polytetrafluoroethylene sheet, respectively. When exposed to basic gas analytes, the paper-like sensor distinctly exhibited a color change from initially yellow, then to green, and finally to blue due to the deprotonation of BCG via the Brønsted acid-base reaction. The use of ammonia analyte as a test gas confirmed that the sensing performance of the optimized sensor was reversible and excellent (detection time of < 15 min, sensitive naked-eye detection at 0.25 ppm, good selectivity to common volatile organic gases, and good stability against thermal stress). Finally, the coloration intensity of the sensor was quantified as a function of the storage time of the salmon filet at 28℃ to evaluate its usefulness in monitoring of the food freshness with the measurement of the total viable count (TVC) of microorganisms in the food. The TVC value increased from 3.2 × 105 to 3.1 × 109 cfu/g in 28 h and then became stable, whereas the sensor response abruptly changed in the first 8 h and slightly increased thereafter. This result suggests that the colorimetric response could be used as an indicator for evaluating the degree of decay of salmon induced by microorganisms.

Structural and Electrical Properties of Nanotube as Various Second Anodizing Time for Biosensor (바이오 센서로의 응용을 위한 2차 양극산화 시간에 따른 나노튜브의 구조적, 전기적 특성)

  • Kim, Yong-Jun;Lee, Tae-Ho;Jung, Hye-Rin;Lee, Sung-Gap
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.741-744
    • /
    • 2013
  • In this study, we fabricated anodic aluminum oxide (AAO) membrane by two step anodizing process for pH detection. The structural properties were observed by X-ray diffraction (XRD) and field emission scanning electron microscope (FE-SEM). Electrochemical measurements of the pH sensor have been performed in capacitance-voltage (C-V) and drift rates. The characterization of AAO membrane exhibited high sensitivity (99.1 mV/pH) at second anodizing time of 4 min.

Study on pH Sensor using Methylene Blue Adsorption and A Long-Period Optical Fiber Grating Pair

  • Jeon Young-Hee;Kwon Jae-Joong;Lee Byoung-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • We propose a new pH-sensing scheme using a methylene blue adsorption on an optical fiber cladding surface. Interactions between the silica and hydroxyl ions of a base solution induce the surface of the silica negatively charged. The charged surface attracts the positively charged chromophores of methylene blue. As the pH of the solution is reduced, the electrostatic attraction will also be reduced. This electrostatic attraction can change the transmitted light intensity of the cladding mode, since the boundary condition changes. We also carried out a simulation to verify the effect from external refractive index change around a long-period fiber grating. Our results confirm that the wavelength shift by external refractive index change is negligible compared to the transmitted light intensity variation of the cladding mode. By using a long-period grating pair, we can detect the cladding mode transmittance variations. Experimentally, we showed the possibility of pH sensing in the $1.5{\mu}m$ infrared region.

Design of a New ISFET Array Chip

  • Yeow, Terence;Seo, Hwa-Il;Mulcahy, Dennis;Haskard, Malcolm
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.55-61
    • /
    • 1995
  • A new ISFET array chip, based on detection of the threshold voltages of ISFETs by using an adjustable input, was designed. The chip includes 240 pH-ISFETs and circuitry such as comparators, a decoder and register. The chip has increased reliability, improved accuracy, digital output capability and the possibility of multi sensor implementation. To fabricate the chip, an extended CMOS process was devised and implemented.

  • PDF

Imaging the Enzymatic Reaction of Urease Using Liquid Crystal-Based pH Sensor

  • Hu, Qiong-Zheng;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4377-4381
    • /
    • 2011
  • In this study, real-time and label-free methods for monitoring the enzymatic reaction of urease, which releases ammonia through the hydrolysis of urea in an aqueous solution, were developed using a liquid crystal (LC)-based pH sensor. Nematic liquid crystal 4-cyano-4'-pentylbiphenyl (5CB), doped with 4'-pentyl-biphenyl-4-carboxylic acid (PBA), exhibited a shift in optical appearance from bright to dark when it was in contact with ammonia generated from the enzymatic reaction between urease and urea. This optical change was attributed to the anchoring transitions of LCs caused by hydrophobic interactions between the tails of deprotonted PBA ($PBA^-$) molecules and the LCs at the aqueous/LC interface. This novel technique holds great promise for the sensitive detection of urease along with its substrates and inhibitors.

A Differential Current-to-Time Interval Converter Using Current-Tunable Schmitt Triggers

  • Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.375-380
    • /
    • 2017
  • A differential current-to-time interval converter is presented for current mode sensors. It consists of a ramp voltage generator, a current mode sensor, a reference current source, two current-tunable Schmitt triggers, a one-shot multivibrator, and two logic gates. The design principle is to apply a ramp voltage to each input of the two current-tunable Schmitt triggers whose threshold voltages are proportional to the drain current values of the current mode sensors. A proposed circuit converts a current change in the ISFET biosensor into its equivalent pulse width change. A prototype circuit built using TSMC 0.18 nm CMOS process exhibit a conversion sensitivity amounting to $726.9{\mu}s/pH$ over pH variation range of 2-12 and a linearity error less than ${\pm}0.05%$.

A study on MPPT control using the balace/unbalance control (평형/불평형 제어를 이용한 MPPT제어에 과한 연구)

  • K., T.K.;K., G.H.;C., K.J.;P., J.W.;Matsui, M.;L., H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.334-336
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current- Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF