• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.037 seconds

Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles (거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극)

  • 정오진
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.211-220
    • /
    • 1996
  • New thin-and diselena-crown ethers containing two suffer and selenium donor atoms have been prepared. And then, mercury ($Hg^{2+}$) ion-selective electrodes with PVC-plasticizer (STPB) based on some macrocycles as neutral carriers were also made. The electrochemical selectivities for various ions, and the effects for macrocycles, matrix of membranes, ratio of plasticizer to macrowcles, concentration and pH of test solution were investigated on the $Hg^{2+}$ ion-selective electrodes. The 1, 10-diselena-18-crown-6-PVC-STPB (sodium tetraphenylborate) exhibited good linear responses of ${28.2}\pm{0.6}$ decade-1 for $Hg^{2+}$ ion in the conientration ranges of $10^{-2}~10^{-6}$ M $Hg^{2+}$ ion. This electrode exhibited comparatively good selectivities for $Hg^{2+}$ ion in comparison with alkali and alkaline earth metal ions, some heavy metal ions and rare earth metal ion in the range of pH 2.5~6.0. In addition, this electrode was applied as a sensor in the titration of $Hg^{2+}$ ion with $1^-$ ion in water.

  • PDF

Determination of L-Asparagine Using Proteus mirabilis Bacterial Electrode (Proteus mirabilis 박테리아 전극을 이용한 L-Asparagine의 정량)

  • Ihn Gwon-Shik;Moo-Jeong Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.422-427
    • /
    • 1988
  • The bio-electrode for L-asparagine, excellent in the reproducibility of responsibility, has been constructed by immobilizing the bacterium Proteus mirabilis on an ammonia gas sensor. This electrode was investigated for the effects of pH, temperature, buffer solution, bacterial amounts and interferences, and stability with the lapse of time. The response of the bacterial electrode was linear in the range of $9.0{\times}10^{-5}$$1.0{\times}10^{-2}M$ L-asparagine with a slope of 58.9mV/decade in pH 7.8, 0.05M phosphate buffer solution at $30^{\circ}C$. The bacterial amounts used for this electrode was 3 mg and response time was 7∼9 min. Therefore, this assembly can be used for the determination of L-asparagine.

  • PDF

Estimation of Chinese Cabbage Growth by RapidEye Imagery and Field Investigation Data

  • Na, Sangil;Lee, Kyoungdo;Baek, Shinchul;Hong, Sukyoung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.5
    • /
    • pp.556-563
    • /
    • 2015
  • Chinese cabbage is one of the most important vegetables in Korea and a target crop for market stabilization as well. Remote sensing has long been used as a tool to extract plant growth, cultivated area and yield information for many crops, but little research has been conducted on Chinese cabbage. This study refers to the derivation of simple Chinese cabbage growth prediction equation by using RapidEye derived vegetation index. Daesan-myeon area in Gochang-gun, Jeollabuk-do, Korea is one of main producing district of Chinese cabbage. RapidEye multi-spectral imagery was taken on the Daesan-myeon five times from early September to late October during the Chinese cabbage growing season. Meanwhile, field reflectance spectra and five plant growth parameters, including plant height (P.H.), plant diameter (P.D.), leaf height (L.H.), leaf length (L.L.) and leaf number (L.N.), were measured for about 20 plants (ten plants per plot) for each ground survey. The normalized difference vegetation index (NDVI) for each of the 20 plants was measured using an active plant growth sensor (Crop $Circle^{TM}$) at the same time. The results of correlation analysis between the vegetation indices and Chinese cabbage growth data showed that NDVI was the most suited for monitoring the L.H. (r=0.958~0.978), L.L. (r=0.950~0.971), P.H. (r=0.887~0.982), P.D. (r=0.855~0.932) and L.N. (r=0.718~0.968). Retrieval equations were developed for estimating Chinese cabbage growth parameters using NDVI. These results obtained using the NDVI is effective provided a basis for establishing retrieval algorithm for the biophysical properties of Chinese cabbage. These results will also be useful in determining the RapidEye multi-spectral imagery necessary to estimate parameters of Chinese cabbage.

Simultaneous Determination of Ranitidine and Metronidazole at Poly(thionine) Modified Anodized Glassy Carbon Electrode

  • Rahman, Md. Mahbubur;Li, Xiao-Bo;Jeon, Young-Deok;Lee, Ho-Joon;Lee, Soo Jae;Lee, Jae-Joon
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.90-94
    • /
    • 2012
  • A simple and sensitive electrochemical sensor for simultaneous and quantitative detection of ranitidine (RT) and metronidazole (MT) was developed, based on a poly(thionine)-modified anodized glassy carbon electrode (PTH/GCE). The modified electrode showed the excellent electrocatalytic activity towards the reduction of both RT and MT in 0.1M phosphate buffer solution (PBS, pH 7.0). The peak-to-peak separations (${\Delta}E_p$) for the simultaneous detection of RT and MT between the two reduction waves in CV and DPV were increased significantly from ca. 100 mV at anodized GCE, to ca. 550 mV at the PTH/GCE. The reduction peak currents of RT and MT were linear over the range from 35 to $500{\mu}M$ in the presence of 200 and $150{\mu}M$ of RT and MT, respectively. The sensor showed the sensitivity of 0.58 and $0.78{\mu}A/cm^2/{\mu}M$ with the detection limits (S/N = 3) of 1.5 and $0.96{\mu}M$, respectively for RT and MT.

Fabrication and Characteristics of Surface-Acoustic-Wave Sensors for Detecting $NO_2$ GaS ($NO_2$ 가스 감지를 위한 표면탄성파 센서의 제작 및 특성)

  • Choi, D.H.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.108-114
    • /
    • 1999
  • Surface acoustic wave (SAW) device is very attractive for gas sensor applications because of their small size, low cost, high sensitivity, and good reliability. A dual delay line surface acoustic wave $NO_2$ gas sensors have been designed and fabricated on the $LiTaO_3$ piezoelectric single crystal substrate. The capacitance of the fabricated IDTs was 326.34pF at the frequency of 79.3MHz. The maximum reflection loss of the impedence-matched IDTs was -16.74dB at the frequency of 79.3MHz. The SAW oscillator was constructed and the stable oscillation was obtained by controlling the gain of rf amplifier properly. The oscillation frequency shift of the SAW oscillator to the $NO_2$ gas was 28Hz/ppm.

  • PDF

Micro humidity sensor with poly imide sensitive layer (폴리이미드를 감지막으로 한 마이크로 정전용량형 습도센서)

  • Shin, P.K.;Cho, K.S.;Park, G.B.;Yuk, J.H.;Park, J.K.;Im, H.C.;Ji, S.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1898-1899
    • /
    • 2005
  • 반도체 집적회로 공정에서 사용되는 폴리이미드 포토레지스트(P12723, Dupont)를 감습막으로 사용하는 마이크로 습도센서 소자를 제작하였다. 마이크로 습도센서는 실리콘 웨이퍼 기판 위에 $SiO_2$ 박막을 건식열산화 공정으로 제작하고, Al 박막을 포토리소그라피 공정으로 패터닝 한 IDT (Interdigital Transducer)를 전극 위에 폴리이미드 포토레지스트를 공정변수를 다양하게 조절하면서 감습막으로 제작하였다. 폴리이미드 감습막은 스핀코팅법으로 제작하였으며, 회전수를 조절하여 두께를 변화시켰다. 완성된 마이크로 습도센서 소자의 상대습도 변화$(10{\sim}90% RH)$에 따른 정전용량 값 변화를 항온항습조 내에서 다양한 온도에서 HP4192A Impedance Analyzer를 사용하여 조사함으로써, 폴리이미드 포토레지스트를 사용하는 마이크로 정전용량형 습도센서의 제작 가능성을 검토하였다. 폴리이미드 정전용량형 마이크로 습도센서는 다양한 인가 전원 주파수에서 기준 센서로 사용된 상용 Vaisala Hygrometer와 유사한 감습특성 및 응답특성을 보였다.

  • PDF

Fabrication of a influenza A H1N1 sensor using ZnO nanostructure (산화아연 나노구조를 이용한 H1N1 인플루엔자 A 바이러스 센서 제작)

  • Jang, Yun-Seok;Park, Jung-Il;Nam, Yoon-Kyung;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1690-1691
    • /
    • 2011
  • 본 논문에서는 H1N1 인플루엔자 A 바이러스(influenza A H1N1 virus) 검출을 위한 산화아연 나노구조(zinc oxide nano structure) 기반의 전기화학적 면역센서를 제작하고 그 특성을 분석하였다. H1N1 인플루엔자 A 바이러스는 빠른 전파 속도 때문에 정확하고 빠른 검출이 필요하다. 먼저, 2 $mm^2$의 표면적을 갖는 패턴된 금 전극 위에 열수방식(hydrothermal method)으로 성장시킨 산화아연 나노구조가 선택적으로 형성되도록 리프트-오프(lift-off) 방법을 사용하였다. 0.01 M phosphate buffered saline(pH 7.4)에서 2 ${\mu}g$/mL 농도의 1차 항체를 정전기력에 의해 산화아연 나노구조에 고정화한 후, 10 pg/mL ~ 5ng/mL 농도의 H1N1 항원을 적용하여 포획 항체에 결합시키고 HRP(horseradish peroxidase) 효소가 결합된 검출 항체를 항원에 결합시키는 샌드위치 ELISA법을 이용하였다. HRP와 반응하는 TMB(3,3', 5,5'-tetramethylbenzidine)와 과산화수소가 포함된 acetate buffered 용액(pH 5)을 전해질로 사용하고 순환전압전류 측정법(cyclic voltammetry)으로 센서의 특성을 분석하였다. 측정된 순환전압전류그래프(cyclic voltammogram)에서 H1N1 항원 농도 10 pg/mL ~ 5 ng/mL의 응답 전류는 276.47 ${\pm}$ 21.72 nA (평균 ${\pm}$ 표준편차, n=4) ~ 478.89 ${\pm}$ 6.21 nA로 측정되었고, logarithmic하게 증가하는 응답 전류 특성을 보였다.

  • PDF

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

Optical Probe for Determination of Chromium(III) Ion in Aqueous Solution Based on Sol-Gel-Entrapped Lucigenin Chemiluminescence

  • Li, Ming;Kwak, Jun-Hee;Kim, Chang-Jin;Lee, Sang-Hak
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.103-108
    • /
    • 2003
  • A method to determine chromium(III) ion in aqueous solution by chemiluminescence method using a lucigenin entrapped silica sol-gel film has been studied. An optical probe for chromium(III) ion has been prepared by entrapping lucigenin into silica sol-gel film coated on a glass support by dip coating. The chromium(III) optical sensor is based on the catalytic effect of chromium(IIII) ion on the reaction between lucigenin and hydrogen peroxide in basic solutions. The effects of Nafion, DMF and Triton X-100 were investigated to find the optimum condition to minimize cracking and leaching from the probe. The effects of pH and concentrations of lucigenin and hydrogen peroxide on the chemiluminescence intensity were investigated. The chemiluminescence intensity was increased linearly with increasing chromium(III) concentration from $2.5{\times}10^{-4}$M to $8.0{\times}10^{-7}$M and the detection limit was $4.0{\times}10^{-7}$M.

  • PDF

A New Rhodamine B Derivative As a Colorimetric Chemosensor for Recognition of Copper(II) Ion

  • Tang, Lijun;Li, Fangfang;Liu, Minghui;Nandhakumar, Raju
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3212-3216
    • /
    • 2010
  • A new rhodamine-based sensor 1 was designed and synthesized by incorporating rhodamine B and benzimidazole moieties. Sensor 1 exhibits high selectivity and sensitivity to $Cu^{2+}$ in $CH_3CN$-water solution (HEPES buffer, pH = 7.0) with an obvious color change from colorless to pink. Other metal ions such as $Hg^{2+}$, $Ag^+$, $Pb^{2+}$, $Sr^{2+}$, $Ba^{2+}$, $Cd^{2+}$, $Ni^{2+}$, $Co^{2+}$, $Fe^{2+}$, $Mn^{2+}$, $Cu^{2+}$, $Zn^{2+}$, $Ce^{3+}$, $Mg^{2+}$, $K^+$ and $Na^+$ had no such color change and have no significant influence on $Cu^{2+}$ recognition process. The interaction of $Cu^{2+}$ and sensor 1 was proven to adopt a 1:1 binding stoichiometry and the recognition process is reversible.