Browse > Article
http://dx.doi.org/10.5229/JECST.2012.3.2.90

Simultaneous Determination of Ranitidine and Metronidazole at Poly(thionine) Modified Anodized Glassy Carbon Electrode  

Rahman, Md. Mahbubur (Department of Advanced Technology Fusion, Konkuk University)
Li, Xiao-Bo (Department of Applied Chemistry, Konkuk University)
Jeon, Young-Deok (Department of Applied Chemistry, Konkuk University)
Lee, Ho-Joon (Department of Applied Chemistry, Konkuk University)
Lee, Soo Jae (Department of Applied Chemistry, Konkuk University)
Lee, Jae-Joon (Department of Advanced Technology Fusion, Konkuk University)
Publication Information
Journal of Electrochemical Science and Technology / v.3, no.2, 2012 , pp. 90-94 More about this Journal
Abstract
A simple and sensitive electrochemical sensor for simultaneous and quantitative detection of ranitidine (RT) and metronidazole (MT) was developed, based on a poly(thionine)-modified anodized glassy carbon electrode (PTH/GCE). The modified electrode showed the excellent electrocatalytic activity towards the reduction of both RT and MT in 0.1M phosphate buffer solution (PBS, pH 7.0). The peak-to-peak separations (${\Delta}E_p$) for the simultaneous detection of RT and MT between the two reduction waves in CV and DPV were increased significantly from ca. 100 mV at anodized GCE, to ca. 550 mV at the PTH/GCE. The reduction peak currents of RT and MT were linear over the range from 35 to $500{\mu}M$ in the presence of 200 and $150{\mu}M$ of RT and MT, respectively. The sensor showed the sensitivity of 0.58 and $0.78{\mu}A/cm^2/{\mu}M$ with the detection limits (S/N = 3) of 1.5 and $0.96{\mu}M$, respectively for RT and MT.
Keywords
Simultaneous detection; Poly(thionine); Ranitidine; Metronidazole; Differential pulse voltammetry;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 A. Salimi, M. Izadi, R. Hallaj and M. Rashidi, Electroanalysis 19, 1668 (2007).   DOI   ScienceOn
2 T. G. do Nascimento, E. de Jesus Oliveira and R. O. Macedo, J. Pharmaceut. Biomed. Anal. 37, 777 (2005).   DOI   ScienceOn
3 K. C. Lamp, C. D. Freeman, N. E. Klutmam and M. K. Lacy, Clin. Pharmacokinet. 36, 353 (1999).   DOI   ScienceOn
4 P. G. Farup, J. Tholfsen, S. Wetternus, R. Torp, O. Hoie and O. J. Lange, Scand. J. Gastroenterol. 37, 1374 (2002).   DOI
5 E. Vega and N. Sola, J. Pharm. Biomed. Anal. 25, 523 (2001)   DOI   ScienceOn
6 S. Kalil, S. A. Ibrahim, F. I. Zedan and M. S. Abd-Elmonem, Chem. Anal. (Warsaw) 50, 897 (2005).
7 Y. M. Issa, S. B. Badawy and A. A. Mutair, Anal. Sci. 21, 1443 (2005).   DOI   ScienceOn
8 C. L. Erroz, P. Vinas, N. Campillo and M. H. Cordoba, Analyst 121, 1043 (1996).   DOI
9 E. Dreassi, G. Ceramelli, P. Corti, P. L. Perruccio and S. Lonardi, Analyst 121, 219 (1996).   DOI
10 A. J. S. Ahammad, S. Sarker, M. A. Rahman and J.-J. Lee, Electroanalysis 22, 694 (2010).   DOI   ScienceOn
11 P. N. Bartlett, E. Ghoneim, G. El-Hefnawy and I. El- Hallag, Talanta 66, 869 ( 2005).   DOI   ScienceOn
12 A. J. S.Ahammad, M. M. Rahman, G.-R. Xu, S. Kim and J.-J. Lee, Electrochimica Acta 56, 5266 (2011).   DOI   ScienceOn
13 M. M. Rahman, A. J. S. Ahammad, J.-H. Jin, S. J. Ahn and J.-J. Lee, Sensors 10, 4855 (2010).   DOI   ScienceOn
14 Y. Yuan, A. J. S. Ahammad, G.-R. Xu, S. Kim and J.-J. Lee, Bull. Korean Chem. Soc. 29, 1883 (2008).   DOI   ScienceOn
15 S. Lu, K. Wu, X. Dang and S. Hu, Talanta 63, 653 (2004).   DOI   ScienceOn
16 P. R. Roy, T. Okajima and T. Ohsaka, J. Electroanal. Chem. 561, 75 (2004).   DOI   ScienceOn