• Title/Summary/Keyword: pH센서

Search Result 351, Processing Time 0.027 seconds

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Piezoelectric properties of (Bi0.5Na0.5)TiO3-BaTiO3 ceramics prepared by reactive templated grain growth method (Reactive Templated Grain Growth법에 의해 제조된 (Bi0.5Na0.5)TiO3-BaTiO3 세라믹스의 압전 특성)

  • Ahn, Byung-Guk
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2007
  • Crystallographically {h00}-oriented $0.94(Bi_{0.5}Na_{0.5})TiO_{3}-0.06BaTiO_{3}$ (0.94BNT-0.06BT) ceramics was prepared by the Reactive Templated Grain Growth (RTGG) method using the $Bi_{4}Ti_{3}O_{12}$ template. The sheets prepared by tape-casting of slurries containing the templates and starting materials are cut, laminated, and pressed. Then burn-out and sintering was conducted. Also, to compare with the 0.94BNT-0.06BT ceramics prepared by the RTGG method another 0.94BNT-0.06BT ceramics was prepared by the solid-state method. In the optimum of this experiments range, the degree of orientation of the 0.94BNT-0.06BT ceramics prepared by the RTGG method was texture fraction${\approx}92%$ and the piezoelectric constant($d_{33}$) and coupling factor($k_{p}$) was obtained to $d_{33}{\approx}205{\;}pC/N$, $k_{p}{\approx}0.33%$, respectively.

Improvement of the Biosensor for Detection of Endocrine Disruptors by Combination of Human Estrogen Receptorα and Co-Activator (Human Estrogen Receptor α와 Co-activator로 구성된 바이오센서를 이용한 내분비계장애물질의 검출)

  • Lee, Haeng-Seog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.893-904
    • /
    • 2006
  • To improve sensitivity of biosensor as yeast two-hybrid detection system for estrogenic activity of suspected chemicals, we tested effects of several combinations of the bait and fish components in the two-hybrid system on Saccharomyces cerevisiae inducted a chromosome-integrated lacZ reporter gene that was under the control of CYC1 promoter and the upstream Gal4p-binding element $UAS_{GAL}$. The bait components that were fused with the Gal4p DNA binding domain are full-length human estrogen receptor ${\alpha}$ and its ligand-binding domain. The fish components that were fused with the Gal4p transcriptional activation domain were nuclear receptor-binding domains of co-activators SRC1 and TIF2. We found that the combination of the full-length human estrogen receptor ${\alpha}$ with the nuclear receptor-binding domain of co-activator SRC1 was most effective for the estrogen-dependent induction of reporter activity among the two-hybrid systems so far reported. The relative strength of transcriptional activation by representative natural and xenobiotic chemicals was well correlated with their estrogenic potency that had been reported with other assay systems.

Optimization for Higher Sensitive Measurements of FET-type Sensors (FET센서 감도 향상 측정을 위한 최적화)

  • Sohn, Young-Soo
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.116-119
    • /
    • 2015
  • Field-effect transistor (FET)-based ion or biosensors have been intensively studied so far. Among many measurement methods, the variation of the drain current can be induced when ions or biomolecules are interacted with sensing membranes located on the gate insulator of FET. One of typical FET-type sensors is an ion-sensitive field-effect transistor (ISFET) utilized in this study. In ISFET, the voltage is usually applied to the reference electrode instead of the gate voltage. Firstly, the voltage applied to the reference electrode versus the drain current was observed, and the steepest slope in this graph was found. Using this point, the optimized condition was established for the larger variation of the drain current in the saturated region in response to the variation of the input in the dynamic range.

Development of a Solid State Ion Sensor Module for Analysis of Hydroponic Nutrients (수경재배용 배양액의 이온성분 분석을 위한 고체형 센서 모듈 개발)

  • Kim, G.;Lee, S.B.;Chang, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.5
    • /
    • pp.348-353
    • /
    • 2007
  • A solid state ion sensor module has been developed and evaluated for hydroponic nutrients analysis. The sensor module consisted of five ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, calcium, and pH were measured with specially designed 7-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The solid state ion sensors exhibit linear relationships over five concentration decades. Detection limit of the sensors were $5.6{\times}10^{-5}{\sim}1.6{\times}10^{-7}M$ depends on ions. Performance test results showed that relative errors of measured ion concentrations were less than 5% for $NO_3{^-},\;K^+,\;Ca^{2+}$ ion, and pH. The concentration of $NO_3{^-},\;NH_4{^+},\;K^+,\;Ca^{2+}$, and pH ion in standard solution and nutrient solutions could be determined by direct potentiometric measurements without any conditioning before measurements.

Effectiveness of the Electrochemical Sensor for the Free Chlorine Measurement (잔류염소 측정용 전기화학센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.720-725
    • /
    • 2012
  • Sodium hypochlorite is used worldwide as a water disinfectant and in bleaching agent. Sodium hypochlorite applied to water initially undergoes hydrolysis to form free chlorine consisting of hypochlorous acid(HOCl) and hypochlorite ion($OCl^-$). For free chlorine determination, an electrochemical method is simple due to the electroactivity of free chlorine; it measures current and is free of most reagents. Amperometric free chlorine sensor has been developed with gold (Au)-based electrode. The 3-electrode free chlorine sensor whose working and counter electrodes were Pt exhibited excellent response to HClO at +400mV vs. Ag/AgCl/sat. KCl. In addition, the use of a pH error correction algorithm provided a reliable measurement of residual free chlorine in water sample without any pretreatment in the normal pH range(pH 6~8) of municipal water supply. The free chlorine sensor installed in on-line monitoring system could be used to continually monitor the level of residual free chlorine in real samples.

Gas Sensing Properties and Mechanism of the $\textrm{SnO}_2-\textrm{In}_2\textrm{O}_3$ System Prepared by Coprecipitation Method (공침법으로 제조된 $\textrm{SnO}_2-\textrm{In}_2\textrm{O}_3$ 계의 가스감응특성 및 감응기구)

  • Yun, Gi-Hyeon;Im, Ho-Yeon;Gwon, Cheol-Han;Yun, Dong-Hyeon;Kim, Seung-Ryeol;Hong, Hyeong-Gi;Lee, Gyu-Jeong
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.813-818
    • /
    • 1998
  • Ultrafine powders of $\textrm{In}_{2}\textrm{O}_{3}$-doped $\textrm{SnO}_{2}$ were synthesized by a coprecipitation method and the effects of pH value and the amount of In2Q addition on particle size were investigated. The influence of pH value on particle size could be negligible, whereas the amount of $\textrm{In}_{2}\textrm{O}_{3}$ has influenced on particle size and specific surface area. The gas sensitivity to hydrocarbOn($\textrm{C}_{3}\textrm{H}_{8}$, $\textrm{C}_{4}\textrm{H}_{10}$) increased with $\textrm{In}_{2}\textrm{O}_{3}$ addition and reached a maximum at 3wt.% addition. From the results of impedance analysis and I-V characteristics. it was showed that the agglomeration structure of particles and the boundaries between agglomerates were the important factors to determine the gas sensing mechanism.

  • PDF

Preparation of Nanostructures Using Layer-by-Layer Assembly and Applications (층상자기조립법을 이용한 나노구조체의 제조와 응용)

  • Cho, Jin-Han
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.2
    • /
    • pp.81-90
    • /
    • 2010
  • We introduce a novel and versatile approach for preparing self-assembled nanoporous multilayered films with antireflective properties. Protonated polystyrene-block-poly (4-vinylpyrine) (PS-b-P4VP) and anionic polystyrene-block-poly (acrylic acid) (PS-b-PAA) block copolymer micelles (BCM) were used as building blocks for the layer-by-layer assembly of BCM multilayer films. BCM film growth is governed by electrostatic and hydrogen-bonding interactions between the oppositely BCMs. Both film porosity and film thickness are dependent upon the charge density of the micelles, with the porosity of the film controlled by the solution pH and the molecular weight (Mw) of the constituents. PS7K-b-P4VP28K/PS2K-b-PAA8K films prepared at pH 4 (for PS7K-b-P4VP28K) and pH 6 (for PS2K-b-PAA8K) are highly nanoporous and antireflective. In contrast, PS7K-b-P4VP28K/PS2K-b-PAA8K films assembled at pH 4/4 show a relatively dense surface morphology due to the decreased charge density of PS2K-b-PAA8K. Films formed from BCMs with increased PS block and decreased hydrophilic block (P4VP or PAA) size (e.g., PS36K-b-P4VP12K/PS16K-b-PAA4K at pH 4/4) were also nanoporous. Furthermore, we demonstrate that the nanostructured electrochemical sensors based on patterning methods show the electrochemical activities. Anionic poly(styrene sulfonate) (PSS) layers were selectively and uniformly deposited onto the catalase (CAT)-coated surface using the micro-contact printing method. The pH-induced charge reversal of catalase can provide the selective deposition of consecutive PE multilayers onto patterned PSS layers by causing the electrostatic repulsion between next PE layer and catalase. Based on this patterning method, the hybrid patterned multilayers composed of platinum nanoparticles (PtNP) and catalase were prepared and then their electrochemical properties were investigated from sensing $H_2O_2$ and NO gas. This study was based on the papers reported by our group. (J. Am. Chem. Soc. 128, 9935 (2006); Adv. Mater. 19, 4364 (2007); Electro. Mater. Lett. 3, 163 (2007)).

2DEG Calculation in InP HEMT (InP HEMT의 2DEG계산)

  • Hwang, K.C.;Ahn, H.K.;Han, D.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.316-318
    • /
    • 2003
  • 양자우물 구조를 사용한 HEMT(High Electron Mobility Transistor)는 고속 스위칭 소자와 초고주파 통신용 소자 및 센서에에 우수한 동작특성을 갖고 있다. 본 논문에서는 AlInAs/InP HEMT의 heterostructure를 파동방정식과 Poisson 방정식을 self-consistent 한 방법으로 해석하였다. 파동방정식으로 junction의 전자농도를 계산하고, Poisson 방정식을 해석하여 potential profile에 의한 전자 농도가 heterostructure에서 self-consistent가 되도록 연산하였다. 끝으로 AlInAs/InP 구조에서 positively ionized donor, valance band에서의 hole, conduction band의 free electron과 구조내의 2DEG를 AlGaAs/GaAs 및 AlGaAs/InGaAs/GaAs와 비교하였다.

  • PDF

Fabrication and Characteristics of SAW Gas Sensor (SAW 가스센서의 제작 및 특성)

  • Jun, C.B.;Park, H.D.;Choi, D.H.;Lee, D.D.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.40-45
    • /
    • 1994
  • $112^{\circ}$ rot. x-cut $LiTaO_{3}$ wafer was used as the substrate of SAW gas sensor. Dual delay line SAW device with IDTs which consist of the reference delay line and the sensing delay line was fabricated using photolithigraphy. Each IDTs had 10 finger pairs and finger spacing is 10 microns. One delay line channel is the reference, while the second is the sensing channel with Pb-phthalocyanine film in the propagation path. Pb-phthalocyanine film which is p-type organic semiconductor was evaporated in $10^{-5}$ torr vacuum using shadow mask selectively. Dual delay line oscillator was constructed by using the rf amplifier and AGC. Frequency of the IDTs had the range of $87{\sim}$89 MHz oscillation frequency. Oscillation frequency shifts were investigated as a function of the temperature and the concentration of $NO_{2}$ gas.

  • PDF