• 제목/요약/키워드: pCAST2

검색결과 290건 처리시간 0.029초

치과보철기공물 제작실태에 관한 조사연구 (A SURVER OF THE ACTUAL CONDITIONS ON THE PRODUCTION OF DENTAL PROSTHESIS)

  • 배정수;정문규
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.358-394
    • /
    • 1995
  • The author studied the actual conditions on the production of dental prosthesis made in laboratories, and also studied interrelationships between dentists and laboratory technicians in both personal and technical aspects. Two hundred-eighty four technicians, work in dental laboratories presently, were surveyed via mail and direct contact during the period from June 1 to June 30 and August 27 to August 28 in 1994 respectively. The obtained results were as follows : 1. Among the respondents, 90.5% we re working in commercial dental laboratories and their laboratories were mainly located in the Seoul area(40.9%, P<0.05). The numbers of employees in these laboratories were less than 10 persons(70.0%, P<0.01), and 75.9% of these laboratories have been in operation less than 15 years. 2. Most laboratory procedures were accomplished according to established disciplines. However, procedures such as die trimming in fixed restorations and the qualifications of the people designing removable partial dentures were not. Other problem areas were boxing of the working cast, the person determining the posterior palatal seal area, selection and arrangement of artificial teeth, occlusion rim correction and laboratory remounting of the processed denture in complete denture restorations. 3. Only half of the requesting dentists could send work authorizations to the laboratories with their work and even so, its contents were quite lacking. Consequently, there must be some standards in writing work authorization. 4. Technicians most desired clean and accurate impressions in fixed and removable dentures, and enough tooth reduction in porcelain fused to metal restorations. 5. For the establishment of better relationships between dentist and dental technician, the respondents desired the establishment of equal footing first(33.5%), and frequent conversations and muture understanding second(25.9%).

  • PDF

물리치료가 슬관절 내측측부인대 손상을 동반한 전방십자인대 재건술 후 운동기능 회복에 미치는 영향 (The effects of functional movement recovery of physical therapy after ACL reconstruction with MCL injury)

  • 김인섭;임원식;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제14권1호
    • /
    • pp.27-37
    • /
    • 2002
  • This is the study of the knee joint injured patients at the orthopaedic surgery clinic where is located in Daejon, who has MCL combine injured ACL reconstruction caused by sport activity and accident during the period from Jan. 2001 to Oct. 2001. By comparing with groups between 7th case of I-group for MCL combined stitch and II-group for ACL reconstruction since 6weeks cast. We have been concluded with that following results. 1. Range of motion for the knee was not limited at 5th case(37%) of I-group, 6th case(42%) of II-group and the cases of Flexion deficit less then 10 -degree were 2nd case(13%) of I-group and II-group 1st case(8%) with no extension deficit more then 5 -degree. 2. The level of activity that tells you whether you are capable of exercise for six month after operation. It han been divided by 3 levels. The case of capable of doing low risk exercise(swimming, cycling, etc.) was 5th case of I-group, the case of capable of doing medium risk exercise(jogging, etc.) was 3rd case of I-group and 4th case of II-group and the case of capable of doing high risk exercise(football, etc.) were 3rd case of I-group and 3rd case of II-group. 3. The timing of the return to their job were average 6.4 weeks for I-group and average 22.9 weeks for II-group(P<.05, statistical difference). 4. There was no statistical difference between I-group and II-group for the timing of the return to their job(P>.05). 5. By using VAS to compare them there was no statistical difference between I-group and II-group of clinical results according to Lysholm scale.

  • PDF

가철성 다이를 가진 작업모형에서 다우엘 핀의 종류에 따른 정확도에 관한 연구 (THE ACCURACY ACCORDING TO THE VARIOUS DOWEL PINS OF WORKING CAST WITH REMOVABLE DIES)

  • 임주환
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.373-384
    • /
    • 1997
  • In this study, 4 types of dowel pin were used to fabricate removable dies using the Pindex system. The comparison of interabutment distances between before and after sawing were conducted in each type of dowel pin, and the horizontal discrepancies in the interabutment distance according to the abutment location and the type of dowel pin were comparatively analyzed. Abutments LM(left molar), LP(left premolar), A(anterior), RP(right premolar), and RM (right molar) were used for measurement. The interabutment distances were measured between each abutment : LM-LP, LM-A, LM-RP, and LM-RM. The slide scanned image of each model was magnified on the computer screen and the measurements were conducted using the meeting point of the cross on the occlusal surface of each abutment. The results were as follows : 1. In the comparison of interabutment distances between before and after sawing in each type of dowel pin, there was no significant difference in World dowel pin(double), Bi-pin(double), Maxcel dowel pin(single). In the World dowel pin(single) there was no significant difference between LM-LPs, but in the other measurements (LM-As, LM-RPs, and LM-RMs) there was significant difference between before and after sawing(p<0.05). 2. In comparison of horizontal discrepancies of the measurement according to the abutment location, there was significant difference between measurement LM-LP($0.27{\pm}0.19mm$) and the others : LM-A($0.46{\pm}0.20mm$), LM-RP($0.38{\pm}0.25mm$), LM-RM($0.45{\pm}0.22mm$) (p<0.05). 3. In comparison of horizontal discrepancies of the measurement according to the type of dowel, there was no significant difference between each dowel. As a result when fabricating a removable die using the previously mentioned 4 types of dowel pins, it is thought that the horizontal discrepancy increased in proportion to the interabutment span length and does not depend on the type of dowel pin.

  • PDF

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.

Positional Cloning and Phenotypic Characterization of a New Mutant Mouse with Neuronal Migration Abnormality

  • Park, Chankyu;Ackerman, Susan-L
    • 한국발생생물학회:학술대회논문집
    • /
    • 한국발생생물학회 2001년도 발생공학 국제심포지움 및 학술대회 발표자료집
    • /
    • pp.14-17
    • /
    • 2001
  • Positional clonging (map-based cloning) of mutations or genetic variations has been served as an invaluable tool to understand in-vivo functions of genes and to identify molecular components underlying phenotypes of interest. Mice homozygous for the cerebellar deficient folia (cdf) mutation are ataxic, with cerebellar hypoplasia and abnormal lobulation of the cerebellum. In the cdf mutant cerebellum approximately 40% of Purkinje cells are ectopically located within the white matter and the inner granule cell layer (IGL). To identify the cdf gene, a high-resolution genetic map for the cdf-gene-encompassing region was constructed using 1997 F2 mice generated from C3H/HeSnJ-cdf/cdf and CAST/Ei intercross. The cdf gene showed complete linkage disequilibrium with three tightly linked markers D6Mit208, D6Mit359, and D6Mit225. A contig using YAC, BAC, and P1 clones was constructed for the cdf critical region to identify the gene. A deletion in the cdf critical region on chromosome 6 that removes approximately 150 kb of DNA selection. cdf mutant mice with the transgenic copy of the identified gene restored the brain abnormalities of the mutant mice. The positional cloning of cdf gene provides a good example showing the identification of a gene could lead to finding a new component of important molecular pathways.

  • PDF

Electromagnetic Wave Absorption Properties in Fe-based Nanocrystalline P/M Sheets with Carbon Black and BaTiO3 Additives

  • Kim, Mi-Rae;Park, Won-Wook
    • 한국분말재료학회지
    • /
    • 제16권1호
    • /
    • pp.33-36
    • /
    • 2009
  • In order to increase the magnetic loss for electromagnetic(EM) wave absorption, the soft magnetic $Fe_{73}Si_{16}B_7Nb_3Cu_1$(at%) alloy strip was used as the basic material in this study. The melt-spun strip was pulverized using an attrition mill, and the pulverized flake-shaped powder was crystallized at $540^{\circ}C$ for 1h to obtain the optimum grain size. The Fe-based powder was mixed with 2 wt% $BaTiO_3$, $0.3{\sim}0.6$ wt% carbon black, and polymer-based binders for the improvement of electromagnetic wave absorption properties. The mixture powders were tape-cast and dried to form the absorption sheets. After drying at $100^{\circ}C$ for 1h, the sheets of 0.5 mm in thickness were made by rolling at $60^{\circ}C$, and cut into toroidal shape to measure the absorption properties of samples. The characteristics including permittivity, permeability and power loss were measured using a Network Analyzer(N5230A). Consequently, the properties of electromagnetic wave absorber were improved with the addition of both $BaTiO_3$ and carbon black powder, which was caused by the increased dielectric loss of the additive powders.

Positional Cloning and Phenotypic Characterization of a New Mutant Mouse with Neuronal Migration Abnormality

  • Park, Chankyu;Ackerman, Susan-L
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2001년도 발생공학 국제심포지움 및 학술대회 발표자료집
    • /
    • pp.14-17
    • /
    • 2001
  • Positional cloning (map-based cloning) of mutations or genetic variations has been served as an invaluable tool to understand in-vivo functions of genes and to identify molecular components underlying phenotypes of interest. Mice homozygous for the cerebellar deficient folia (cdf) mutation are ataxic, with cerebellar hypoplasia and abnormal lobulation of the cerebellum. In the cdf mutant cerebellum approximately 40% of Purkinje cells are ectopically located within the white matter and the inner granule cell layer (IGL). To identify the cdf gene, a high-resolution genetic map for the cdf-gene-encompassing region was constructed using 1997 F2 mice generated from C3H/HeSnJ-cdf/cdf and CAST/Ei intercross. The cdf gene showed complete linkage disequilibrium with three tightly linked markers D6Mit208, D6Mit359, and D6Mit225. A contig using YAC, BAC, and P1 clones was constructed for the cdf critical region to identify the gene. A deletion in the cdf critical region on chromosome 6 that removes approximately 150kb of DNA was identified. A gene associated with this deletion was identified using cDNA selection. cdf mutant mice with the transgenic copy of the identified gene restored the brain abnormalities of the mutant mice. The positional cloning of cdf gene provides a good example showing the identification of a gene could lead to finding a new component of important molecular pathways.

  • PDF

도재 전장 금관용 비귀금속 합금의 결합강도에 관한 연구 (A study on the Bond Strength of Non-Precious Alloys Used for the Porcelain Fused to Metal Crown)

  • 김철만;이종혁;조인호
    • 구강회복응용과학지
    • /
    • 제22권3호
    • /
    • pp.203-210
    • /
    • 2006
  • Although porcelain fused to metal crowns made from non-precious metal have good mechanical properties, they also have disadvantages such as the poor biological acceptability and the low corrosional resistance. Titanium is used as the alternative metal for porcelain fused to metal crowns, in spite of difficulties in casting. For that reason non-precious alloy including titanium which is easy to cast is currently used. This study evaluated the bond strength between non-precious alloy including titanium and Ni-Cr alloy. $Tilite^{(R)}V$ as non-precious alloy including titanium, $Rexilium^{(R)}V$ as Ni-Cr alloy and $Omega900^{(R)}$ and $Vintage(Regular)^{(R)}$ as porcelain powders were used. The results were as follows. 1. In comparison with the kind of alloy, the bond strength of $Tilite^{(R)}V$ was lower than that of $Rexilium^{(R)}V$. There was no significant difference between two groups. 2. In comparison with the kind of porcelain powder, the bond strength of $Omega900^{(R)}$ was higher than that of $Vintage(Regular)^{(R)}$ in $Tilite^{(R)}V$. There was significant difference between two groups(p < 0.05).

개인 트레이의 설계와 인상채득방법이 의치 변연의 형태에 미치는 영향에 관한 연구 (THE EFFECT OF INDIVIDUAL TRAY DESIGN AND IMPRESSION METHOD ON THE BORDER EXTENSION AND CONTOUR OF DENTURE)

  • 이정우;오상천;진태호
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.13-23
    • /
    • 1995
  • The purpose of this study is to inquire about the effects of individual tray design and impression method on the border extension and contour of denture. 10 students at the dentistry college who have normal occlusion and symmetric facial form and normal facial muscle activity were selected. The tray was designed three types (large, medium, small tray). After border molding was done by dentist and operator, final impression was taken. The length of impression body and width of border were measured by a vernier caliper on the cast. The obtained results were as follows : 1. As the tray border was shortened, the length of impression body and width of border was short (P<0.01). 2. When the impression was taken with the small tray, the length of impression body was short in passive border molding than active border molding. 3. When the medium tray was used, the width of impression body was short in passive border molding than active border molding.

  • PDF

Ag2Se Modified TiO2 Heterojunction with Enhanced Visible-Light Photocatalytic Performance

  • Zhu, Lei;Tang, Jia-Yao;Fan, Jia-Yi;Sun, Chen;Oh, Won-Chun
    • 한국재료학회지
    • /
    • 제31권12호
    • /
    • pp.657-664
    • /
    • 2021
  • To build a highly active photocatalytic system with high efficiency and low cast of TiO2, we report a facile hydrothermal technique to synthesize Ag2Se-nanoparticle-modified TiO2 composites. The physical characteristics of these samples are analyzed by X-ray diffraction, scanning electron microscopy with energy dispersive X-ray analysis, transmission electron microscopy and BET analysis. The XRD and TEM results show us that TiO2 is coupled with small sized Ag2Se nanoplate, which has an average grain size of about 30 nm in diameter. The agglomeration of Ag2Se nanoparticles is improved by the hydrothermal process, with dispersion improvement of the Ag2Se@TiO2 nanocomposite. Texbrite BA-L is selected as a simulated dye to study the photodegradation behavior of as-prepared samples under visible light radiation. A significant enhancement of about two times the photodegradation rate is observed for the Ag2Se@TiO2 nanocomposite compared with the control sample P25 and as-prepared TiO2. Long-term stability of Ag2Se@TiO2 is observed via ten iterations of recycling experiments under visible light irradiation.