• Title/Summary/Keyword: p-mixing

검색결과 1,322건 처리시간 0.024초

밀기울 첨가수준이 알팔파 Silage 품질에 미치는 영향 (Effects of Quality of Alfalfa Silage by Different Wheat Bran Mixing Levels)

  • 신재순;차영호;이혁호;김정갑;진현주;정기영
    • 한국초지조사료학회지
    • /
    • 제16권3호
    • /
    • pp.225-229
    • /
    • 1996
  • To find out the optimum mixing level of wheat bran to improve the quality of 1st cut Alfalfa silage, this trial was canied out at two-year's Alfalfa monoculture field of the National Livestock Research Institute, Suwon, Korea, from May 1955 to Oct. 1995. The results are as follows. I. According to the increase of wheat bran mixing level, DM content was high from 23.19%(nil) to 35.70%(40% mixing), pH of silage were low from 5.51(nil) to 4.45(40% mixing). but there were not significant at 20% mixing or more(P>0.05). 2. Also it was appeared to the same trend at Lactic acid content and in the Flieg's score of silage it was highest as 59 in the 20% mixing level. 3. In chemical component of silages there were not significant at 20% mixing or more in crude protein, crude fiber and ashes content, 30% mixing or more in ether extract and 10% or less in NFE content(P>0.05). 4. TDN, NEL and StE contents were low as adding level was increased. respectively, but there were not significant(P>O.OS). As mentioned above the results, desirable mixing level of wheat bran to lstcut Alfalfa to improve the quality of silage was 20% of fresh weight.

  • PDF

PASS-100을 이용한 응집처리시 물리.화학적 인자의 영향 (Effect of Physicochemical Parameter on PASS-100 Flocculation)

  • 이상일;서인석;박승국
    • 환경위생공학
    • /
    • 제10권2호
    • /
    • pp.30-35
    • /
    • 1995
  • In this research effect of physicochemical parameter on flocculation using PASS-100 were evaluated. pEt flocculant dosage, mixing intensity and detention time were adopted as experimental variables. The physicochemical parameter( p% mixing intensity and mixing time ) were important Parameter on flocculation performance. Effluent pH range for effective flocculation was 4.5-7. Optimum Gt$_{d}$ range was 20,000-30,000 and its range similar to alum flucculation. Rapid mixing was very important parameter to floe formation in PASS- 100 flocculation. Whereas, slow mixing did not affect to the removal efficiency at settling time for 30minute or more.

  • PDF

비파 퓨레 첨가량을 달리한 양갱의 품질특성 (Quality Characteristics of Yanggaeng containing Various Amounts of Loquat Fruits Puree)

  • 권순용;정장호;박기봉
    • 한국조리학회지
    • /
    • 제21권2호
    • /
    • pp.75-84
    • /
    • 2015
  • 본 연구는 비파를 이용한 양갱의 최적 배합 비율과 비파 퓨레와 비파양갱의 이화학적 품질특성을 조사하였다. 그 결과, 비파 퓨레의 첨가량이 증가할수록 수분, 당도, pH, 항산화 활성 및 폴레페놀 함량이 증가하였고, 관능적 품질 특성에서는 비파 퓨레 60~80% 첨가시에 선호도가 높았다. 따라서 비파양갱의 최적 배합비율은 비파 퓨레를 60% 첨가시 맛과 기호도에서도 좋으며, 다양한 기능성이 기대되는 양갱을 만들 수 있을 것으로 기대된다.

Validity of Blockwise Bootstrapped Empirical Process with Multivariate Stationary Sequences

  • Kim, Tae-Yoon;Shin, Ki-Dong;Song, Gyu-Moon
    • Journal of the Korean Statistical Society
    • /
    • 제30권3호
    • /
    • pp.407-418
    • /
    • 2001
  • Buhlmann(1944) established the validity of the block bootstrap proposed by Kunsch when it is applied to p-dimensional $\alpha$-mixing dependent sequence. But his result requires a rather restrictive condition on p in the sense that p is entangled with dependence structure. We address that such restriction on p(or complication of dependence structure with p) could be removed completely when the underlying dependence structure is replace by more weakly dependent structure such as ø-mixing.

  • PDF

3D 프린터용 시멘트 복합체의 배합요인에 따른 출력 품질의 실험적 평가 (Experimental Evaluation of the Effect of the Mixing Design Factors of the Cementitious Composite for 3D Printer on the Printing Quality)

  • 서지석;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.89-96
    • /
    • 2022
  • 이 논문에서는 건설용 ME 방식 3D 프린터로 출력하기 위한 시멘트 복합체 배합의 출력품질을 평가하기 위해 출력 외관의 육안검사와 출력물의 치수 오차율, 압축강도 및 휨강도를 측정하였다. 시험결과, 출력 불연속 정도, 표면 무결성, 형태 유지능력, 출력가능 여부와 같은 4개 지표를 모두 만족하는 우수한 배합은 P1-2, P1-4, P2-5, P2-6으로 나타났다. 3개 지표를 만족하는 배합은 P0-1, P1-1, P1-3, P1-6, P1-7, P2-4으로 나타났다. 이 배합 중 오차율 측정용 중공 원주형 공시체의 직경 치수 오차율과 높이 치수율이 낮은 배합은 P0-1, P2-6로 나타났다. 치수 오차율이 우수한 배합과 그렇지 않은 배합의 압축강도 및 휨강도를 평가한 결과 출력 품질이 우수한 배합의 역학적 특성이 우수한 것으로 나타났다. 그러나, 역학적 특성이 우수한 배합이 반드시 출력 품질이 우수한 것은 아니기 때문에 정확한 품질평가를 위해서는 출력 외관에 대한 육안검사와 치수 오차율 검사를 선행하여 역학적 특성을 검토해야 할 것으로 판단된다.

Direct Stacking of Non-metallic Planar Porphyrin to DNA

  • Lee, Min-Ju;Jin, Biao;Lee, Hyun-Mee;Jung, Maeng-Joon;Kim, Seog K.;Kim, Jong-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권8호
    • /
    • pp.1533-1538
    • /
    • 2008
  • Porphyrins generally bind DNA in two different ways with respect to the mixing ratio; monomeric binding at a low mixing ratio and outside stacking at a high mixing ratio. In the present study, CTDNA binding property of a planar structured porphyrin, 5,10,15,20-tetrakis(N-methyl-4-pyridin-4-yl-phenyl)porphyrin (referred to as B-TMPyP) was investigated using absorption, CD, LD, and $LD^r$ spectroscopies. B-TMPyP produced a bisignate CD band, even at the lowest mixing ratio, indicating that B-TMPyP may not have a monomeric binding mode. From the observations of the spectral changes to the absorption, CD, and LD spectra in mixing ratio dependent titrations, B-TMPyP seems to have a quite different stacking type compared to that for the binding of $H_2$TMPyP. Moreover, B-TMPyP produced a CD band of opposite shape in the Soret band region. A qualitative explanation for the observed optical differences is also given.

자동혈구분석기(Technicon $H^*2$ )에 의한 혈액검체의 측정전 Mixing 횟수가 검사결과에 미치는 영향에 관한 평가 (Evaluation of Prior-Mixing Effect Using Technicon $H^*2$)

  • Ein Soon Shin;Yong-Suk Ryang
    • 대한의생명과학회지
    • /
    • 제1권1호
    • /
    • pp.73-79
    • /
    • 1995
  • 자동혈구분석기(Technicon $H^*2$ )에 의한 혈액검체의 측정전 mixing횟수가 검사결과에 미치는 영향을 평가하기 위하여 19가지 parameter를 대상으로 초기측정치에 대한 반복측정치의 변화율을 종속변수로 하여 단순회귀분석을 실시하였다. Mixing횟수가 증가할수록 RBC, Hct, MCV는 통계적으로 유의하게 (p< .01)감소하였고, 호염기구 백분율은 유의하게(p< .05)증가하였으므로 평가된 19가지 parameter의 21%인 4가지 검사항목에서 변화가 있었다.

  • PDF

Development of a Low-cost Metering Device for Automatic Mixing of Nutrient-Solution

  • Ryu, K.H.;Lee, K.C.;Lee, J.H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1117-1125
    • /
    • 1996
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering accuracy of the metering device developed was compared with commercial metering pumps. The mixing performance through the control of EC and pH was also evaluated. The accuracy of the metering device in terms of the full -scale error was $\pm$0.3% , which was much better compared to $\pm$2.45% and $\pm$1.38% for the two types of commercial metering pumps. The mixing system of nutrient-solution with the metering device showed a satisfactory control performance with the accuracies of $\pm$0.05mS/cm and$\pm$0.2pH for EC and pH, respectively.

  • PDF

Uniform Ergodicity of an Exponential Continuous Time GARCH(p,q) Model

  • Lee, Oe-Sook
    • Communications for Statistical Applications and Methods
    • /
    • 제19권5호
    • /
    • pp.639-646
    • /
    • 2012
  • The exponential continuous time GARCH(p,q) model for financial assets suggested by Haug and Czado (2007) is considered, where the log volatility process is driven by a general L$\acute{e}$vy process and the price process is then obtained by using the same L$\acute{e}$vy process as driving noise. Uniform ergodicity and ${\beta}$-mixing property of the log volatility process is obtained by adopting an extended generator and drift condition.

수종 인상재의 혼합방법에 따른 기포형성과 표면 재현력에 관한 연구 (A STUDY ON THE VOID FORMATION AND DETAIL REPRODUCTION ACCORDING TO THE VARIOUS IMPRESSION MATERIALS AND MIXING METHODS)

  • 류형선;임헌송;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.140-155
    • /
    • 2002
  • Void-free impression taking is important for the fabrication of accurate dental restorations. One of the essential properties of an impression material used for indirect fabrication of precision castings is the reproduction of the fine detail. The objective in this study was to determine the influence of mixing methods on the number of voids and surface detail reproduction. The number of voids and surface detail reproduction were evaluated with the steteomicroscope $SZ-PT^{(R)}$ and photographed. The results were as follows ; 1. In comparison of the void formation according to mixing methods of all impression materials, mechanical mixing was better than hand mixing and there was significant difference(p<0.05) 2. In comparison of the void formation according to hand mixing of alginate impression materials($TOKUSO\;A-1{\alpha}^{(R)},\;CAVEX\;IMPRESSIONAL^{(R)},\;AROMA \;FINE\;DF\;III^{(R)}$), there was no significant difference among alginate groups. But the number of void was increased in the order of $Panasil^{(R)}\;contact,\;TOKUSO\;A-1{\alpha}^{(R)},\;Permlastic^{(R)}$ light bodied and there was significant difference (p<0.05). 3. In comparison of the void formation according to mechanical mixing of alginate impression materials($TOKUSO\;A-1{\alpha}^{(R)},\;CAVEX\;IMPRESSIONAL^{(R)},\;AROMA FINE\;DF\;III^{(R)}$), there was no significant different among alginate groups. But the number of void was decreased in order of $TOKUSO\;A-1{\alpha}^{(R)},\;Permlastic^{(R)}light\;bodied,\;Panasil^{(R)}$ contact and there was significant difference (p<0.05). 4. In comparison of the surface detail reproduction according to mixing methods of 3 types of impression materials($TOKUSO\;A-1{\alpha}^{(R)},\;Permlastic^{(R)}\;light\;bodied,\;Panasil^{(R)}\;contact$), there was no significant difference between hand mixing and mechanical mixing method 5. The surface detail reproduction was only influenced by impression materials, and produced better in order of $TOKUSO\;A-1{\alpha}^{(R)},\;Panasil^{(R)}\;contact,\;Permlastic^{(R)}$ light bodied. There was significat difference among 3 type of impression materials(p<0.05). From the above results, void formation is influenced by mixing methods and surface detail reproduction is influenced by impression materials than mixing methods. Therefore, to fabricate accurate restorations, proper impression material and mechanical mixing method are more effective and available clinically.