• Title/Summary/Keyword: p-filters

Search Result 219, Processing Time 0.027 seconds

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Application of the Partial Discharge Measuring Method in Operating Transformer (운전중인 변압기의 부분방전 측정기법 적용)

  • 권동진;최인혁;정길조
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

Catalytic NiO Filter Supported on Carbon Fiber for Oxidation of Volatile Organic Compounds

  • Sim, Jong Ki;Seo, Hyun Ook;Jeong, Myung-Geun;Kim, Kwang-Dae;Kim, Young Dok;Lim, Dong Chan
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.7
    • /
    • pp.2105-2110
    • /
    • 2013
  • Carbon-fiber-supported NiO catalytic filters for oxidation of volatile organic compounds were prepared by electroless Ni-P plating and subsequent annealing processes. Surface structure and crystallinity of NiO film on carbon fiber could be modified by post-annealing at different temperatures (500 and $650^{\circ}C$). Catalytic thermal decompositions of toluene over these catalytic filters were investigated. $500^{\circ}C$-annealed sample showed a higher catalytic reactivity toward toluene decomposition than $650^{\circ}C$-annealed one under same conditions, despite of its lower surface area and toluene adsorption capacity. X-ray diffraction and X-ray photoelectron spectroscopy studies suggest that amorphous structures of NiO on $500^{\circ}C$-annealed catalyst caused the higher reactivity for oxidation of toluene than that of $650^{\circ}C$-annealed sample with a higher crystallinity.

Preparation and Characterization of Plasmid DNA Encapsulated in Liposomes (플라스미드 유전자를 함유한 리포좀의 제조 및 특성)

  • Park, Hyo-Min;Chung, Soo-Yeon;Go, Eun-Jung;Lee, Hwa-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.3
    • /
    • pp.209-213
    • /
    • 2003
  • The objective of this study was to construct the pegylated liposomes containing plasmid DNA with optimal encapsulation efficiency. Plasmid DNA $(pGL2\;clone\;753,\;{\sim}6\;kb)$ was encapsulated by the freeze/thawing method into liposomes composed of 1-palmitoyl-2-oleyl-sn-glycerol-3-phosphocholine (POPC), didodecyl dimethyl ammonium bromide (DDAB), distearoylphosphatidyl ethanolamine polyethylene glycol 2000 (DSPE-PEG 2000) and DSPE-PEG 2000-male-imide. The liposomes containing plasmid DNA were then extruded through two stacked polycarbonate filters with series of different pore sizes to control the liposome size. The plasmid DNA entrapped in the liposomes was separated from free plasmid DNA by Sephadex CL-4B column chromatography. The decreased pore size of polycarbonate filters resulted in the decreased size of liposomes. The encapsulation efficiency was markedly affected by the cationic lipid (DDAB) concentration, but to a low degree by the size of liposomes and by the amount of plasmid DNA.

Catalytic Oxidation of Toluene Using NiO Filter Supported on Carbon Fiber

  • Sim, Jong Ki;Seo, Hyun Ook;Jeong, Myung-Geun;Kim, Kwang-Dae;Nam, Jong Won;Kim, Young Dok;Lim, Dong Chan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.217-217
    • /
    • 2013
  • Carbon-fiber-supported NiO catalytic filters for oxidation of volatile organic compounds were prepared by electroless Ni-P plating and subsequent annealing processes. Surface structure and crystallinity of NiO film on carbon fiber could be modified by post-annealing at different temperatures (500 and $650^{\circ}C$. Catalytic thermal decompositions of toluene over these catalytic filters were investigated. $500^{\circ}C$ annealed sample showed a higher catalytic reactivity toward toluene decomposition than $650^{\circ}C$ annealed one under same conditions, despite of its lower surface area and toluene adsorption capacity. X-ray diffraction and X-ray photoelectron spectroscopy studies suggested that amorphous structures of NiO on $500^{\circ}C$ annealed catalyst caused the higher reactivity for oxidation of toluene than that of $650^{\circ}C$ annealed sample with a higher crystallinity.

  • PDF

Simultaneous NO2 and RSP Measurements Using Filtration Method (필터방식을 이용한 이산화질소 및 호흡성 분진의 동시 측정)

  • Yang, Won-Ho;Im, Sung-Kuk;Kim, Moon-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.148-152
    • /
    • 2008
  • Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide ($NO_2$) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for $NO_2$, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 ml), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the $NO_2$ and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 nm on a spectrophotometer. The collection efficiency(%) of $NO_2$ by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was $89{\pm}3%$ and the correlation coefficient between the true $NO_2$ concentration and that determined by the TEA soaked filters was 0.993(p<0.001).

An Image Signal Processor for Ultra Small HDGrade Video Sensor with 3A in Camera Phones

  • Jang, Won-Woo;Kim, Joo-Hyun;Han, Hag-Yong;Yang, Hoon-Gee;Kang, Bong-Soon
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.4
    • /
    • pp.507-515
    • /
    • 2009
  • In this paper, we propose an image signal processor (ISP) for an ultra small HD-grade video sensor with 3A (AWB, AE, and AF) in camera phones that can process 720P/30fps videos. In order to enhance the video quality of the systems, it is necessary to achieve the high performance of the 3A. The proposed AWB algorithm multiplies the adjusted coefficients of color gains to the captured data of white objects. The proposed AE method adopts the index step moving based on the difference between an averaged Y luminance and a target luminance, together with IIR filters with variable time responses. The proposed AF technique controls the focus curve to find the lens position that maximizes the integrated high frequency components in luminance values by using highpass filters. Finally, we compare the image quality captured from our system to the quality of a commercial HD camcorder in order to evaluate the performance of the proposed ISP. The proposed ISP system is also fabricated with 0.18um CMOS flash memory process.

Meta-analysis of Inline Filtration Effects on Post-infusion Phlebitis Caused by Particulate Contamination of Intravenous Administration

  • Ku, Hye-Min;Kim, Ji-Yeon;Kang, Suk-Hyun;Lee, Eui-Kyung
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.4
    • /
    • pp.225-230
    • /
    • 2010
  • The particulate contamination of intravenously administered fluid has been of major concern. One of the most common complications associated with long term i.v. therapy is post-infusion phlebitis (PIP). We undertook a systematic review and meta-analysis of the effect of inline filters on PIP. An electronic search of Medline, KoreaMed, and KRIST was conducted to identify randomized controlled trials evaluating the effect of inline filters. Meta-analysis was undertaken using STATA 10. A total of 62 literatures were retrieved, of which 7 were included in meta-analysis. Inline filtration for intravenous infusion significantly reduced by 39% of the incidence of phlebitis, with a relative risk of 0.61 (95% CI 0.41-0.90, p=0.012). Therefore, inline filtration is a highly effective means of decreasing the incidence of infusion phlebitis and should be considered as a part of intravenous therapy.