• 제목/요약/키워드: p-filters

검색결과 217건 처리시간 0.031초

도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구 (Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation)

  • 이병규;신용철
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

THE CONVERGENCE OF δ-FILTERS

  • Lee, Seung On;Oh, Ji Hyun;Yun, Sang Min
    • 충청수학회지
    • /
    • 제24권1호
    • /
    • pp.35-43
    • /
    • 2011
  • In this paper we define the convergence of ${\delta}$-filters and study them. We show that ${\delta}$-filters on a Hausdorff space X converge at most one point in X. We also show that in a P-space X, ${\delta}$-filters on X converge at most one point in X if and only if X is a Hausdorff space.

방진 마스크 필터 교체와 성능 변화의 상관성 조사 (Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators)

  • 이헌용;박지훈;윤충식
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.

주파수 통과대역필터가 작업 기억 관련 사건관련전위 P300에 미치는 영향 (Effects of the Frequency Band Pass Filter on the P300 Event-related Potential in the Working Memory)

  • 박웅식;이정우
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.131-138
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.

Filtered-based GPS structural vibration monitoring methods and comparison of their performances

  • Zhong, P.;Ding, X.L.;Zheng, D.W.;Chen, W.
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.2
    • /
    • pp.137-141
    • /
    • 2006
  • The purpose of GPS structural vibration monitoring is to obtain information on the frequency and amplitude of vibrations based on GPS observations that are often affected by various errors. Filters are frequently used to improve GPS accuracy and to retrieve vibration signals from GPS observational series. This paper studies the performances of four commonly used filters, i.e., Vondrak, wavelet, adaptive FIR and Kalman filters, for such applications. Controlled experiments are carried out and the results show that the capability of GPS in tracking structural dynamics and complex signals can be improved with any of the filters. The performances of Vondrak and wavelet filters are almost the same and superior to the adaptive FIR and Kalman filters. Recommendations are given for the selection of filters and filter parameters for different situations based on an analysis of the advantages and disadvantages of each of the filters.

  • PDF

HAUSDORFF INTERVAL VALUED FUZZY FILTERS

  • Ramakrishinan, P.V.;V. Lakshmana Gomathi Nayagam
    • 대한수학회지
    • /
    • 제39권1호
    • /
    • pp.137-148
    • /
    • 2002
  • The notion of Interval Valued Fuzzy Sets (IVF sets) was introduced by T. K. Mondal. In this paper a notion of IVF filter is introduced and studied. A new notion of Hausdorffness, which can not be defined in crisp theory of filters, is defined on IVF filters and their properties are studied.

IMPLICATIVE ORDERED FILTERS OF IMPLICATIVE SEMIGROUPS

  • Jun, Young-Bae
    • 대한수학회논문집
    • /
    • 제14권1호
    • /
    • pp.47-55
    • /
    • 1999
  • This paper continues the investigations of implicative semigroups and of their ordered filters which were started in general case by M.W. Chan and K. P. Shum [3]. In particular, the notion of an implicative ordered filter of an implicative semigroup is introduced. We state some equivalent conditions for an ordered filter to be an implicative ordered filter and obtain the so called extension property for implicative ordered filters.

  • PDF

Recent Advances In Small Molecule OLED Microdisplays

  • Ghosh, Amalkumar P.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.235-238
    • /
    • 2007
  • eMagin's unique OLED-on-silicon microdisplay technology is unique and is based on small molecule white OLED with color filters using a top emitter structure. This paper will present results of recent improvements in the technology including improved lifetimes and uniformity and will feature an SVGA resolution full color microdisplay that is 0.44 inches diagonal.

  • PDF

막여과지에 의한 무단체 Ag-111에 관한 연구 (Studies on Carrier-Free Silver-111 with Membrane Filters)

  • 제원목
    • 대한화학회지
    • /
    • 제17권5호
    • /
    • pp.319-323
    • /
    • 1973
  • 무단체 Ag-111의 상태를 여과법에 의하여 연구하였다. 이 연구는 막여과자에 의하여 수용액에 있어서 Ag-111의 pH 및 농도변화에 대한 효과를 조사하였다. 이 연구결과 막여과지에 대한 Ag-111의 부착은 Freundlich 흡착 등온식에 따르고 Ag-111의 흡착상태는 AgOH 형태로 존재하며 높은 pH에서 흡착성이 없는 $Ag(OH)_{2}-$는 Ag의 흡착을 방해하는 것으로 생각된다. 또한 무단체 Ag-111는 수용액중에서 $Ag^+$상태로 존재하고 있다.

  • PDF

가속도 맥파를 이용한 혈관탄성 추정에 관한 연구 (A Study on Estimate Vascular Compliance using Acceleration Photoplethymogram)

  • 이충렬;김경호
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.840-844
    • /
    • 2013
  • In this study, we try to estimate vascular compliance for management vascular disease. Because It is known the vascular compliance represents the state of the blood vessels. In general, the vascular compliance is estimated using an acceleration photoplethymogram from measured by photoplethymogram-based. The acceleration photoplethymogram is come from second derivative of photoplethymogram. By using the acceleration photoplethymogram, we can estimating vascular compliance, vascular age, vascular state. In this study, for measuring acceleration photoplethymogram we have developed a measurement device having analog filters. It has the advantage of miniaturization, low-power because it is simpler than digital filters. Using the developed device, we have estimated vascular compliance and tested the reliability of our device compare with conventional device having digital filters. As a result.