• 제목/요약/키워드: ozone-water

검색결과 584건 처리시간 0.044초

전산유체역학을 이용한 실규모 오존 접촉에서의 수리거동과 유효 체적 평가에 관한 연구 (Evaluating Effective Volume and Hydrodynamic Behavior in a Full-Scale Ozone Contactor with CFD Simulation)

  • 박노석;;;배철호;이선주
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.656-665
    • /
    • 2004
  • An Ozone reaction model combined with CFD(Computational Fluid Dynamics) technique was developed in this research, in the simulation of ozonation, hydrodynamic behavior as well as reaction model is important because ozone is supplied to treated water as gas ozone. In order to evaluate hydrodynamic behavior in an ozone contactor, CFD technique was applied. CFD technique elucidated hydrodynamic behavior in the selected ozone contactor, which consisted of three main chambers. Three back-mixing zones were found in the contactor. The higher velocities of water were observed in the second and third compartments than that in the first compartment. The flow of the opposite direction to the main flow was observed near the water surface. Based on the results of CFD simulation, the ozone contactor was divided into small compartments. Mass balance equations were established were established in each compartment with reaction terms. This reaction model was intended to predict dissolved ozone concentration, especially. We concluded that the model could predict favorably the mass balance of ozone, namely absorption efficiency of gaseous ozone, dissolved ozone concentration and ozone consumption. After establishing the model, we discussed the effect of concentration of gaseous ozone at inlet, temperature and organic compounds on dissolved ozone concentration.

반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구 (A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water)

  • 손영수;함상용;문세호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

불포화 토양내에서 가스상 오존 이동특성에 대한 Multiphase liquids의 영향

  • 정해룡;최희철
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.124-127
    • /
    • 2003
  • Laboratory scale experiments on in-situ ozonation were carried out to delineate the effects of liquid phases, such as soil water and nonaqeous phase liquid (NAPL) on the transport of gaseous ozone in unsaturated soil. Soil water enhanced the transport of ozone due to water film effect, which prevent direct reaction between soil particles and gaseous ozone, and increased water content reduced the breakthrough time of ozone because of increased average linear velocity of ozone and decreased air-water interface area. Diesel fuel as NAPL also played a similar role with water film, so the breakthrough time of ozone in diesel-contaminated soil was significantly reduced compared with uncontaminated soil. However, ozone breakthrough time was retarded with increased diesel concentration, because of high reactivity of diesel fuel with ozone. In multiphase liquid system of unsaturated soil, the ozone transport was mainly Influenced by nonwetting fluid, diesel fuel in this study.

  • PDF

상수원수 수질변화에 따른 전오존 처리효과 및 경제성 평가 (Evaluation of Pre-ozone Treatment and Economic Efficiency as Changing Raw Water Quality)

  • 최동훈;박진식;문추연;이재용;류동춘;장성호;권기원;이수애
    • 한국환경과학회지
    • /
    • 제22권4호
    • /
    • pp.453-461
    • /
    • 2013
  • This study, changes in raw water quality is to indicate on the efficiency of ozone treatment of each pollutant as compared to derive the appropriate operating measures. The appropriate selection for injection rate of pre-ozone and did not inject pre-ozone assess changes in the water. When good water quality, you not injected of pre-ozone to evaluate the economic efficiency of electricity and put the most cost-effective ozone concentration were evaluated. Evaluation remove organic matter and chlorophyll-a concentration level in experiments with each factor of the water DOC> 2.5 mg/L, THMFP> 70 ${\mu}g/L$, Chl-a> 30 $mg/m^3$or less constant process, if you do not need to put pre-ozone showed little impact. It also does not put you in pre-ozone appropriate produce enough power rate savings was calculated as approximately 90 million won. Ability to remove organic materials and the ability to produce disinfection byproducts, and cost-effective decisions by considering the concentration of injection if pre-ozone 1 mg/L was investigated by the appropriate concentration of ozone injection.

정수처리에서 미량유해물질 제거를 위한 Peroxone 공정의 적용성 및 경제성 평가 (Evaluation of Applicability and Economical Efficiency of Peroxone Process for Removal of Micropollutants in Drinking Water Treatment)

  • 손희종;김상구;염훈식;최진택
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.905-913
    • /
    • 2013
  • We compared the applicability and economical efficiency of peroxone process with those of ozone process in the existing water treatment plant on downstream of Nakdong River. After comparing the peroxone process for removing geosmin with the ozone process in lab scale test, peroxone process showed much higher removal efficiency than the ozone process at the same ozone dosage. Proper range of $H_2O_2/O_3$ ratio were 0.5~1.0 and the half-life of geosmin was about 5.5~6.8 min when the $H_2O_2/O_3$ ratio was set to 0.5 during 1~2 mg/L of ozone dosage. Peroxone process could reduce the ozone dosage about 50 to maximum 30% for the same geosmin removal efficiency compared to the ozone process in the pilot scale test. In case of 1,4-dioxane treatment, peroxone process could have 3~4 times higher efficiency than ozone process at the same ozone dosage. The results of estimating the economical efficiency of ozone and peroxone process for treating geosmin and 1,4-dioxane by using pilot scale test, in case of the removal target was set to 85% for these two materials, the cost of peroxane process could be reduced about 1.5 times compared to ozone process, and in the same production cost peroxone process could have 2~3 times higher removal efficiency than ozone process. The removal efficiency by peroxone process showed a large difference depending on the physicochemical characteristics of target materials and raw water, therefore detailed examination should be carried out before appling peroxone process.

수중 오존의 분해에 관한 연구 (A study on dissolved ozone in water)

  • 김영배;조국희;서길수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2041-2043
    • /
    • 2000
  • Ozone is widely used to sterilize food and tap water because ozone is a strong oxidizer. To date, it has been difficult to dissolve a high concentration of ozone gas in water because the large size of the bubbles limits the contact area between the ozone gas and liquid water. The measurements of dissolved ozone can be used to control water quality and ozone dosage. Therefore the dissolved ozone measurement of most interest is that of residual ozone at the discharge point of a particular treatment chamber.

  • PDF

고효율 오존장치를 이용한 NOM 제거 및 Bromate 생성 특성 (Investigation on Bromate Formation and Removal of NOM during Ozonation in Super Ozone Mass Transfer Reactor)

  • 송기주;최일환;백경희;이상태
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1137-1143
    • /
    • 2006
  • In this study we investigated the removal characteristics of NOM and bromate formation characteristics in SOMT reactor. The system was recently developed as a novel ozone reactor and installed in SJ pilot plant. DOC values were decreased within 3% after treatment of 0.5~2.0 mg/L ozone dosage in SOMT reactor while the $UV_{254}$ value was 69% decreased at 2.0 mg/L ozone dosage. The composition of NOM was analysed by LC-OCD (Organic Cabon Detector) after ozone treatment in SOMT reactor to elucidate the variation of NOM character. Polysaccharide (more than 20,000 g/mol) fraction of NOM was decomposed while building blocks (350~500 g/mol) and neutral (less than 350 g/mol) fraction increased. Spiked bromide reacted with 0.5~2.0 mg/L ozone dosage in the SOMT reactor. The bromate formation was proportional to the ozone dosage ($R^2=0.978$) but not proportional to reaction time. The maximum concentration of formated bromate was not exceeded to 10% of spiked bromide concentration.

오존의 정수처리 적용을 위한 오존소비인자에 관한 연구 (A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application)

  • 강태희;오병수;권순범;손병용;강준원
    • 대한환경공학회지
    • /
    • 제27권6호
    • /
    • pp.663-669
    • /
    • 2005
  • 본 연구에서는 정수처리 공정에서 오존을 보다 효율적으로 적용하기 위하여 수중의 오존소비특성을 파악하고자 하였다. 오존의 소비특성을 측정하기 위하여 흐름주입분석법(FIA: Flow injection analysis)의 원리를 이용하여 오존분해속도 측정 자동화장치를 제작하였다. 수중의 오존농도를 연속적으로 측정함으로써 오존의 소비 경향은 순간적으로 오존이 소모되는 구간(I.D: instantaneous ozone demand)과 의사 1차 반응($k_c$: pseudo first-order rate constant)으로 소모되는 두 구간으로 나누어지며, 각 구간에서 오존 주입량에 의하여 영향을 받는 것으로 나타났다. 또한 I.D와 $k_c$값을 이용하여 구한 모델식으로부터 시간에 따른 오존 잔류농도를 예측할 수 있었으며, 예측된 모델간은 실험값과 비교하였을 때 거의 일치하는 것을 알 수 있었다. OH 라디칼의 농도 및 $R_{ct}$는 OH 라디칼 probe compound를 이용하여 간접적으로 계산하였다. I.D와 $k_c$ 구간에서 OH 라디칼 생성 경향을 파악할 수 있었으며, OH 라디칼 생성 또한 오존 주입량에 의하여 영향을 받는다는 것을 확인하였다. 마지막으로 정수처리 공정 및 계절에 따른 수질 차이에 의해서 오존소비인자가 변화하는 것을 확인하였으며, 이에 따라 오존공정의 적절한 도입위치 및 주입량을 효과적으로 결정해야 할 것으로 판단되었다.

사이드스트림 오존 접촉조에서 수처리 효율 향상을 위한 정적혼합기와 미세기포에 관한 연구 (A Study on the Static mixer and Microbubble of the Sidestream Ozone Contact System to Improve Water Treatment Efficiency)

  • 김진훈;박종호
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.763-768
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.

실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측 (Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments)

  • 조민;정현미;김이호;손진식;박상정;윤제용
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.