• Title/Summary/Keyword: ozone in Korea

Search Result 771, Processing Time 0.037 seconds

Assessing Factors Linked with Ozone Exceedances in Seoul, Korea through a Decision Tree Algorithm

  • Park, Sun-Kyoung
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.191-216
    • /
    • 2016
  • Since prolonged exposure to elevated ozone ($O_3$) concentrations is known to be harmful to human health, appropriate control strategies for ozone are needed for the non-attainment area such as Seoul, Korea. The goal of this research is to assess factors linked with the 1-hour ozone exceedance through a decision tree model. Since ozone is a secondary pollutant, lag times between ozone and explanatory variables for ozone formation are taken into account in the model to improve the accuracy of the simulation. Results show that while ozone concentrations of the previous day and $NO_2$ concentrations in the morning are major drivers for ozone exceedances in the early afternoon, meteorology plays more important role for ozone exceedances in the late afternoon. Results also show that a selection of lag times between ozone and explanatory variables affect the accuracy of predicting 1-hour ozone exceedances. The result analyzed in this study can be used for developing control strategies of ozone in Seoul, Korea.

Synoptic Weather Patterns and Variation of Ozone Concentrations Association with High Ozone Days at Five Major Cities in Korea (고농도 오존이 발생하는 날의 종관 기상 패턴과 주요 5대 도시별 오존 농도 변화)

  • 김유라;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.437-444
    • /
    • 2001
  • The characteristic features of surface ozone concentration and the forecasting procedure of high ozone days have been studied. The ozone concentration was continuously measured during 3 years (1997~1999) at air quality monitoring stations in five major cities in Korea. The diurnal variation of surface ozone concentration on high ozone days is characterized by low ozone concentration at night. The ozone concentration Increases continuously after sunrise, In reach a peak at 1500~1600 LST. Thereafter it decreases steadily to a low concentration at sunset. The diurnal and annual maximum of the surface ozone concentration at Seoul were observed in May and June, respectively. The favorable synoptic condition for the high ozone day is divided into 4 different synoptic weather patterns: a high-pressure system from the Sea of Okhotsk, the Pacific subtropical high extending westward, a moving high-pressure system covering the Korean peninsula. and a synoptic system In front of a typhoon. Most of high ozone days occur under the high pressure system in Korea.

  • PDF

The Long Term Trends of Tropospheric Ozone in Major Regions in Korea

  • Shin, Hye Jung;Park, Ji Hoon;Park, Jong Sung;Song, In Ho;Park, Seung Myung;Roh, Soon A;Son, Jung Seok;Hong, You Deog
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.235-253
    • /
    • 2017
  • This study was conducted for analyzing the contribution factors on ozone concentrations and its long term trends in each major city and province in Korea through several statistical methods such as simple linear regression, generalized linear model, KZ-filer, correlation matrix, Kringing method, and cluster analysis. The overall ozone levels in South Korea have been consistently increasing over the past 10 years. The ozone concentrations in Seoul, the biggest city in Korea, are the lowest in all areas with the highest increasing ratio for $95^{th}%$ ozone. It is thought that the active photochemical reaction could affect the higher ozone concentration increase. On the other hand, the ozone concentrations in Jeju are the highest in Korea with the highest increasing ratio for $5^{th}%$, $33^{th}%$, and $50^{th}%$ ozone. It is also thought that the weak $NO_x$ titration could be the reason of higher ozone concentrations in Jeju. In case of Jeju, transport related factors is the major factor affecting the ozone trend. Thus, it is assumed that the variation of ozone trend of Asian region affecting the ozone trend in Jeju, where domestic ozone photochemical reaction is less active than urban area. It is thought that the photochemical reaction plays the role of increasing of ozone concentrations in the urban area, even though the LRT affected on the increase of ozone concentrations in non-urban area.

A Comparative study on Ambient Air Quality Standard for Ozone (오존 대기 환경기준의 비교 연구)

  • 허정숙;김태오;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.159-173
    • /
    • 1999
  • Based on air quality monitoring data('89~'97) operated by the Department of Environment, we provide various fundamental statistics for ground ozone. The purpose of this paper are to review the national ambient ozone standard, to study spatial distribution of ozone. Since we, in Korea, calculate average ozone level, to examine the occurrences of ozone level 3 times a day (1~8, 9~16, 17~24 hours), the method does not seem to be scientifically sound comparing to a running average method adapted by the USEPA. When we counted the number of cases with 8-h average O3 level exceeding 60ppb(8-h average standard in Korea)and 80 ppb (that in the U.S.A) and also when we calculated 8-hour average ozone level based on th US method, some regions were classified as non-attainment areas. Especially in Seoul, results of spatial distribution analysis showed that high level ozone over 80 ppb was observed at Kuui-Dong and Pangi-Dong in the eastern part and at Ssangmun-Dong in the northeastern part. Also, occurrences of ozone episode defined as number of days then ozone level exceeding 80 ppb for 3 consecutive hours were extensively reviewed in this paper.

  • PDF

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Development of a Micro-Bubble System for Ozone Off-Gas Recycling in the Ozone Treatment Process (오존처리공정의 배오존 재활용 마이크로버블시스템 개발)

  • Young-Man, Cho;Jae-Ouk, Jung;Kwang-Heon, Lee;Yong-Jun, Jung
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1061-1068
    • /
    • 2022
  • The purpose of this study was to develop a recycling system for ozone off-gas. Although the ozone transmission rate of the injector method differs slightly depending on the ozone injection rate, it reaches approximately 99%, which is very high. During the increase in water inflow to the ozone recycling system from 2 L/min to 10 L/min, the average ozone recycling rate was 99.4% at a 1 ppm ozone injection rate, 98.6% at a 2 ppm ozone injection rate, 98.1% at a 3 ppm ozone injection rate. Ozone treatment facility operating costs can be divided into the costs of pure oxygen production, ozone production, and maintenance. The annual operating costs of ozone treatment facilities in Korea are estimated to be approximately 38.9 billion won. The annual savings are estimated to be approximately 5.8 billion won when the ozone transfer rate of the diffuser method, which is mostly employed in domestic water treatment plants, is 85% and 15% of the ozone is recycled.

A study on dissolved ozone in water (수중 오존의 분해에 관한 연구)

  • Kim, Young-Bae;Cho, Hook-Hee;Seo, Kil-Soo;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2041-2043
    • /
    • 2000
  • Ozone is widely used to sterilize food and tap water because ozone is a strong oxidizer. To date, it has been difficult to dissolve a high concentration of ozone gas in water because the large size of the bubbles limits the contact area between the ozone gas and liquid water. The measurements of dissolved ozone can be used to control water quality and ozone dosage. Therefore the dissolved ozone measurement of most interest is that of residual ozone at the discharge point of a particular treatment chamber.

  • PDF

Characteristics on the Variations of the Total Ozone over Pohang (1994-2004) using the Brewer Spectrophotometer and TOMS

  • Hong Gi-Man;Choi Byoung-Cheol;Goo Tae-Young;Lim Jae-Chul;Lim Byung-Sook;Baek Moon-Hee
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.388-391
    • /
    • 2005
  • The characteristics of the total ozone variations measured by the ground-based Brewer Ozone Spectrophotometer and the Total Ozone Mapping Spectrometer (TOMS) over Pohang are statistically examined from January 1994 to December 2004. First of all, in the correlation analysis of the total ozone measured from the Brewer Ozone Spectrophotometer and the TOMS, the correlation coefficient was 0.88 and the used data were 2190. The annual mean value of the total ozone is 311 DU with the standard deviation of 13 DU. The maximum and the minimum value were found in March (343 DU) and in September (282 DU), respectively. It was also revealed that the longest seasonal variation is in Spring (341 DU) and the smallest is in Autumn (283 DU). The time series data of the total ozone indicates that the annual variation is significant and the variations for three months and six months are relatively weak. Finally, the annual mean total ozones in Pohang (Brewer), Seoul (Brewer) and Busan (TOMS) are 312 DU, 324 DU and 304 DU, respectively.

  • PDF

A ROCKET MEASUREMENT OF OZONE CONCENTRATION PROFILE OVER THE KOREAN PENINSULA USING THE KOREAN SOUNDING ROCKET KSR-420S : OZONE DETECTOR, ITS CALIBRATION AND DATA REDUCTION

  • Kim, Jhoon;Ryoo, Jang-Soo;Park, Chang-Joon;Lim, Heung-Bin;Lee, Ki-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.193-202
    • /
    • 1992
  • The fist sounding rocket in Korea, KSR-420S has been under the development at Korea Aerospace Research Institute (KARI), and is expected to be launched in 1993 to measure the vertical ozone profile over the Korean Peninsula. The KSR-420S is expected to provide the fist in situ measurement of ozone concentrations over the Korean Peninsula. An optical ozone detector has been developed at Korea Research Institute of Standards and Science (KRISS), and its calibration has been completed recently. In this paper, measurement principles of the ozone detector in KSR-420S, its calibration data, ozone measurement procedure and data reduction algorithm are presented with sample calculations.

  • PDF

Growth, Physiological Responses and Ozone Uptake of Five Betula Species Exposed to Ozone

  • Lee, Jae-Cheon;Han, Sim-Hee;Kim, Pan-Gi;Jang, Suk-Seong;Woo, Su-Young
    • The Korean Journal of Ecology
    • /
    • v.26 no.4
    • /
    • pp.165-172
    • /
    • 2003
  • The objectives of this study were to examine the physiological responses to ozone and to measure ozone uptake rates of Betula species exposed to relatively high concentration of pollutants. At the end of the growing season, photosynthesis, pigments contents, antioxidants (SOD and GR) and ozone uptake rates were measured or estimated at the leaves of five Betula species (Betula costata, B. davurica, B. platyphylla var. japonica, B. schmidtii and B. ermanii) exposed to 100ppb ozone concentration. On the termination of the experiment, growth effects were determined by measuring leaf area and dry weights of leaf, stem and root. Ozone treatment showed the significant reduction the leaf area and dry weight of four Betula species, except for B. ermanii. Shoot / root (SR) ratio of five species represented two different types. SR ratio of B. costata and B. davurica were lower than control, in contrast, SR ratio of B. platyphylla var. japonica, B. schimidtii and B. emani, were higher than that of control. The photosynthetic responses of five species were different in responses to ozone exposure. Four species, except for B. emanii, maintained or increased the stomatal conductance, but B. emanii decreased both stomatal conductance and photosynthesis. SOD activities of five species decreased by the ozone exposure, especially B. ermanii showed the largest reduction, GR activities of B. platyphylla var. japonica and B. schmidtii increased, B. costata and B. emanii decreased. Instantaneous ozone uptake rate was the highest at the leaves of B. ermanii and B. costata, ozone uptake per seedling was the highest at the leaf of B. schmidtii and B. emanii. It was concluded that B. costata, B. davurica and B. platyphylla var. japonica, appeared the growth reduction and visible ozone injury, were sensitive species to ozone, and B. schmidtii with the increased antioxidant activity and B. ermanii without the growth reduction were relatively resistant species to high ozone concentration at the early growing stage.