• 제목/요약/키워드: ozone and temperature

검색결과 362건 처리시간 0.019초

오존발생기와 저온 유전체장벽 플라즈마를 이용한 오존 발생 및 살균력 (Disinfective Properties and Ozone Concentrations in Water and Air from an Ozone Generator and a Low-temperature Dielectric Barrier Discharge Plasma Generator)

  • 이영식;전형주;한형균;정정조
    • 한국환경과학회지
    • /
    • 제22권8호
    • /
    • pp.937-944
    • /
    • 2013
  • Ozone concentrations in water and air, and resulting disinfective properties, were measured following generation by either an ozone generator or a low-temperature dielectric barrier discharge plasma generator. In freshwater, ozone concentrations of 0.81 and 0.48 mg/L $O_3$ were observed after the ozone and plasma generators had been operated for five minutes, respectively. Higher levels of dissolved $O_3$ were attained more easily with the ozone generator. In seawater, both systems were capable of creating concentrations greater than 3.00 mg/L $O_3$ after 5minutes of operation. Higher ozone levels were attained more easily in seawater than in freshwater. Rates of bacterial sterilization in seawater after three minutes were 96% and 88%, using the plasma and ozone generators, respectively. In freshwater, higher concentrations of ozone were released into the atmosphere by the ozone generator than by the plasma generator. In creating equivalent levels of dissolved ozone in freshwater, the plasma generator released 4.5 times more ozone into the atmosphere than did the ozone generator. This shows that ozone generators are more effective than plasma generators for creating ozonated water. For the same concentration of dissolved ozone in seawater, more ozone was released into the atmosphere using the ozone generator than using the plasma generator. Therefore, with regard to air pollution, plasma generators seem to be less expensive than ozone generators.

Vertical Structures of Temperature and Ozone Changes in the Stratosphere and Mesosphere during Stratospheric Sudden Warmings

  • Kim, Jeong-Han;Jee, Geonhwa;Choi, Hyesun;Kim, Baek-Min;Kim, Seong-Joong
    • Journal of Astronomy and Space Sciences
    • /
    • 제37권1호
    • /
    • pp.69-75
    • /
    • 2020
  • We analyze the observations of temperature and ozone measured by the Microwave Limb Sounder (MLS) during the period of 2005-2016, to investigate the vertical structures of temperature and ozone in the stratosphere and mesosphere during stratospheric sudden warming (SSW). We compute the height profiles of the correlation coefficients between 55 height levels of MLS temperature anomalies and compare them with the results of Whole Atmosphere Community Climate Model simulations for three major SSWs. We also construct the temperature and ozone anomalies for the events to investigate the changes in the temperature and ozone distributions with height. There seems to always be a relatively weak but broad negative correlation between the temperature anomaly at 10 hPa and temperature anomalies over the entire mesosphere during the period before SSW events. However, this pattern gets stronger in the lower mesosphere but becomes a positive correlation in the upper mesosphere and lower thermosphere after the onset of SSW. We also found that the temperatures from the simulations show a similar trend to the observational results but with smaller variations and the transition height from negative to positive correlation in the mesosphere is much lower in the simulation than in the actual observations.

오존($O_{3}$)을 이용한 면직물의 표백에 관한 연구 (A Study on the Bleaching of Cotton Fabrics by utilizing Ozone(($O_{3}$))

  • Cho, Hwan;Seo, Mal Young;Yu, Jae Sun;Lee, Byung Hyun;Huh, Man Woo;Lee, Kwang Woo;Cho, In Sul;Jong, Hee Cheon
    • 한국염색가공학회지
    • /
    • 제5권4호
    • /
    • pp.49-59
    • /
    • 1993
  • In order to study the bleaching of cotton fabrics, ozone which has been produced by an ozone generator, has been contacted with cotton fabrics in water at various conditions. The equipments used for the ozone treatment of cotton fabrics were the ozone generator and a liquor/ozone contactor. For the examination of the ozone bleaching effect on cotton fabrics the whiteness, tensile strength, wettability and clark softness of the ozone treated cotton fabrics were measured. The conclusion obtained were, ozone concentration was increased, as the voltage was increased and flow rate was decreased and oxygen amount was increased. Bleaching effect of treated fabrics increased with increasing attributed more the net concentration of ozone rather than the total ozone amount of produced. The whiteness of treated fabrics was found to be best when treating temperature was 15~20<$^{\circ}C$, in acidic condition. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised, and the acidity increased. The wicking distance of treated fabrics increased slightly with increasing the treating time and the temperature. Clark softness of treated fabrics was not changed until passing 30min. of the treating time, then it decreasing linealy with increasing the treating time.

  • PDF

부산 해안지역의 고농도 오존 발생 특성에 관한 연구 (Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea)

  • 전병일
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

수중 미량 잔류항생물질 Ciprofloxacin, Trimethoprim, Enrofloxacin의 오존산화제거 (Removal of Residual Antibiotics-Ciprofloxacin, Trimethoprim and Enrofloxacin-from Water by Ozone Oxidation)

  • 한민수;최연우;송준혁;왕창근
    • 한국물환경학회지
    • /
    • 제34권2호
    • /
    • pp.149-156
    • /
    • 2018
  • Oxidation of Ciprofloxacin, Trimethoprim, and Enrofloxacin by ozone was experimentally investigated to observe the effects of background water quality (such as ultrapure water, humic acid, and biologically treated wastewater) and water temperature on the removal rate of these antibiotics, and, thereby, to be able to provide design information when the ozone treatment process is adopted. Initial concentrations of the antibiotics spiked to $10{\mu}g/L$, and the ozone dose was 1, 2, 3, 5, and 8 mg/L. While the removal rate of Ciprofloxacin under ultrapure water background by ozone oxidation was over 99%, the removal rate under humic acid and biologically treated wastewater background was markedly lower, in the range of 49.3% ~ 99% and 19.8 % ~ 99 %, respectively. When water temperature is decreased from $20^{\circ}C$ to $4^{\circ}C$, the removal rate is reduced from the range of 19.8% ~ 99 % to the range of 7.5 % ~ 99 % under a biologically treated wastewater background. The effects of background and temperature on the removal rate of Trimethoprim and Enrofloxacin were similar to that of Ciprofloxacin, but the degree was different. Therefore, it is concluded that the background of water to be treated, as well as water temperature, should be taken into consideration when the design factor, such as ozone dose, is determined, so that the treatment objective of the ozone treatment process can be most effectively met.

수중 미량 잔류항생물질 Erythromycin, Sulfamethazine, Sulfathiazole의 오존산화제거 (Removal of Residual Antibiotics - Erythromycin, Sulfamethazine and Sulfathiazole - from water by Ozone Oxidation)

  • 최연우;한민수;송준혁;왕창근
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.347-356
    • /
    • 2017
  • Oxidation of erythromycin, sulfamethazine and sulfathiazole by ozone was experimentally investigated to see the effects of background water quality such as ultrapure water, humic acid and biologically treated wastewater and water temperature on the removal rate, consequently to provide design information when the ozone treatment process is adopted. Initial concentration of the antibiotics was spiked to $10{\mu}g/l$ and ozone dose was 1, 2, 3, 5, 8 mg/l. While the removal rate of erythromycin under ultrapure water background by ozone oxidation was over 99%, that under humic acid and biologically treated wastewater background was markedly reduced to the range of 59.8%~99% and 17.0%~99%, respectively. When water temperature is decreased from $20^{\circ}C$ to $4^{\circ}C$, the removal rate is reduced from the range of 17.0%~99% to the range of 9.4%~97.4% under biologically treated wastewater background. The effects of background and temperature on the removal rate of sulfamethazine and sulfathiazole were similar to erythromycin, but the degree was different. Therefore, it is concluded that the background of water to be treated as well as water temperature should be taken into consideration when the design factor such as ozone dose is determined to meet the treatment objective in the ozone treatment process.

붕소가 도핑된 다이아몬드 전극을 이용한 오존 발생의 효과 및 응용 (Ozone Generation Effect and application using Boron-doped Diamond Electrode)

  • 피영민;;박수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.170-172
    • /
    • 2002
  • Thin, Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped diamond(BDD) were used as anode for generating ozone gas by electrolysis of acid solution. In this work, we have studied ozone generating system using BDD electrode. In order to determine the ozone generation properties of diamond electrode, experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable for electrolyte while $PbO_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte.

  • PDF

Effect of Temperature on the Performance Characteristics of a Pin-Cylinder Discharge Type Ozonizer

  • Md. Fayzur Rahman;Chun, Byung-Joon;Lee, Kwang-Sik;Lee, Dong-In
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제12C권4호
    • /
    • pp.201-207
    • /
    • 2002
  • A Pin-Cylinder discharge type ozonizer was designed and manufactured. The increase or decrease of temperature greatly influences on the characteristics of ozone generation of a discharge type ozonizer. The characteristics of ozone concentration ( $O_{3con}$), ozone generation ($_{3g}$) and ozone yield .ate ($_{3Y}$) of the ozonizer were investigated by varying the gas flow rate (Q), the discharge power ($_{Wd}$ ) and the temperature (T). At T = 20($^{\circ}C$), the values of ( $O_{3con}$) were found as 7800,5300,3000 and 2300(ppm) at Q=1,2,4 and 6(1/min) respectively. The corresponding values of ( $O_{3g}$) were found as 917, l247,1411 and 1623(mg/h) and those of ( $O_{3Y}$) were 93,126,143 and 164(g/kWh) respectively. When the temperature is decreased to -50($^{\circ}C$), the values of ( $O_{3con}$) became 12000,8000,5200 and 3600(ppm) at Q=1,2,4 and 6(1/min) respectively. The corresponding values of 0,9 were obtained as 1411,1882,2446 and 2600(mg/h) and those of ($O_{3Y}$) were 143,190,247 and 2631g/kWh] respectively. Hence as the temperature was decreased from 20 to -50[。C], the efficiencies of ozone generation were increased by 54,51,73 and 60[%] at Q=1,2,4 and 6(1/min) respectively.ctively.

Effect of Gaseous Ozone Exposure on the Bacteria Counts and Oxidative Properties of Ground Hanwoo Beef at Refrigeration Temperature

  • Cho, Youngjae;Muhlisin, Muhlisin;Choi, Ji Hye;Hahn, Tae-Wook;Lee, Sung Ki
    • 한국축산식품학회지
    • /
    • 제34권4호
    • /
    • pp.525-532
    • /
    • 2014
  • This study was designed to elucidate the effect of ozone exposure on the bacteria counts and oxidative properties of ground Hanwoo beef contaminated with Escherichia coli O157:H7 at refrigeration temperature. Ground beef was inoculated with 7 Log CFU/g of E. coli O157:H7 isolated from domestic pigs and was then subjected to ozone exposure ($10{\times}10^{-6}kg\;O_3h^{-1}$) at $4^{\circ}C$ for 3 d. E. coli O157:H7, total aerobic and anaerobic bacterial growth and oxidative properties including instrumental color changes, TBARS, catalase (CAT) and glutathione peroxidase (GPx) activity were evaluated. Ozone exposure significantly prohibited (p<0.05) the growths of E. coli O157:H7, total aerobic and anaerobic bacteria in ground beef samples during storage. Ozone exposure reduced (p<0.05) the CIE $a^*$ value of samples over storage time. The CIE $L^*$ and CIE $b^*$ values of the samples fluctuated over storage time, and ozone had no clear effect. Ozone exposure increased the TBARS values during 1 to 3 d of storage (p<0.05). The CAT and GPx enzyme activities were not affected by ozone exposure until 2 and 3 d of storage, respectively. This study provides information about the use of ozone exposure as an antimicrobial agent for meat under refrigerated storage. The results of this study provide a foundation for the further application of ozone exposure by integrating an ozone generator inside a refrigerator. Further studies regarding the ozone concentrations and exposure times are needed.

Disinfection Effect of Chlorine, Chlorine Dioxide end Ozone on Total Coliform in Water

  • Lee, Yoonjin;Kyoungdoo Oh;Byongho Jun;Sangho Nam
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.140-143
    • /
    • 2003
  • This research was to determine and compare the inactivation of total coliform as the indicator organism with chlorine, chlorine dioxide and ozone for drinking water treatment. The inactivation of total coliform was experimentally analyzed for the dose of disinfectant, contact time, pH, Temperature and DOC. The experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform as a general indicator organism based on chlorine, chlorine dioxide and ozone as disinfectants. The nearly 2.4, 3.0, 3.9 log inactivation of total coliform killed by injecting 1mg/L at 5 minutes for chlorine, chlorine dioxide and ozone. For the inactivation of 99.9%, Disinfectants required were 1.70, 1.00 and 0.60 mg/L for chlorine, chlorine dioxide and ozone, respectively. The bactericidal effects of disinfectants were decreased as the pH increased in the range of pH 6-9. The influence of pH change on the killing effect of chlorine dioxide was not strong, but that on ozone and free chlorine was sensitive. The bactericidal effects of the disinfectants were increased as the temperature increase. The activation energies were 36,053, 29,822, 24,906 J/mol of chlorine, chlorine dioxide, ozone for coliforms. The inactivation effects were shown in the lowest order of chlorine, chlorine dioxide and ozone.

  • PDF