• Title/Summary/Keyword: oxygen sensor

Search Result 309, Processing Time 0.025 seconds

Failure Case Studies of Sensors for Electronic Controlled Engine in LPG Vehicle (LPG 자동차에서 전자제어엔진용 센서의 고장사례에 관한 연구)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • The purpose of this paper analyzes and investigates the failure case studies of electronic control sensors for a LP gas engine. The malfunction of crank angle sensor, which controls a fuel injection volume of LP gas, displays an irregular and non-uniform pulse wave form. The pulse form, which is related to the noise of the crank angle sensor, displays at the rectangular peak with a saw-toothed shape and is intermittently generated with a level of 2.46V noise signal. The malfunction of No. 1 TDC sensor in which is caused from the internal disorder affects to the reduction of engine power and engine stop suddenly. If the malfunction of oxygen sensor is occurred due to a wiring problem of a sensor connector, the LP gas vehicle may produce a shaking and disharmony of an engine because of no signal supply from the oxygen sensor. The air cleaner replica produces the clogging of continuous supply of fresh air. This may cause the retardation of vehicle acceleration and engine disharmony intermittently.

Solid Electrochemical Method of Measuring Hydrogen Concentration with O2-/H+ Hetero-Ionic Junction

  • Chongook Park
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.63-69
    • /
    • 2024
  • A novel method for measuring hydrogen concentration is introduced, along with its working principle and a novel detection algorithm. This configuration requires no additional reference compartment for potentiometric electrochemical measurements; therefore, it is the most suitable for measuring dissolved hydrogen in the liquid phase. The sensor's electromotive force saturates at a certain point, depending on the hydrogen concentration during the heating process of the sensor operation. This dynamic temperature scanning method provides higher sensitivity than the constant temperature measurement method.

Development and Evaluation of a Teensy Microcontroller-based O2 Mass Flow Controller (Teensy 마이크로 컨트롤러 기반 산소 유량 제어기 개발 및 성능평가)

  • Yu, Min Sang;Jang, Yeonsook;Kim, Muhwan;Cho, Sungbo
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.193-200
    • /
    • 2021
  • Flowmeter and oxygen sensors are listed in COVID-19 essential medical devices. This article reports a Teensy microcontroller-based Oxygen mass flow controller (MFC), core part of the oxygen respirator or extracorporeal membrane oxygenation (ECMO). The developed MFC consisting of the microcontroller, MEMS flow sensor, and solenoid valve was able to accurately control 0 to 100 sccm of oxygen flow rate. The pressure of vacuum chamber increased proportionally to the flow rate (0.998 of Pearson correlation coefficient). The experimental results proved that the developed MFC exhibits comparable performance to a commercial MFC in accuracy, settling time, linearity with pressure, and repeatability of oxygen mass flow control. It is expected that this simple and cheap MFC is utilized for oxygen therapy against the severe acute respiratory syndrome coronavirus 2.

Research on the Characteristics of the Oxygen Rich Combustion Preburner (산화제 과잉 예연소기 연소특성 연구)

  • Moon, In-Sang;Moon, Il-Yoon;Kang, Sang-Hun;Lee, Soo-Yong;Ha, Seong-Up
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.65-69
    • /
    • 2012
  • An oxygen rich preburner was tested and the responses from the pressure sensors were studied with FFT analysis. Since the limited capability of the static sensor, less than 250 Hz frequency domain was investigated and compared to the results of the dynamic sensors. As a result, 60 Hz harmonics were presented dominant in the combustion pressure and oxygen inlet pressure. While similar harmonics were shown with the dynamic sensor, it indicated that harmonics less than 60 Hz were very minor and the high frequency is more important.

  • PDF

ZnO Nanowire-film Hybrid Nanostructure for Oxygen Sensor Applications

  • Jeong Min-Chang;Oh Byeong-Yun;Myoung Jae-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.58-61
    • /
    • 2006
  • Carefully designed ZnO nanowire-film hybrid nanostructure, composed of a bottom ZnO film, ZnO nanowire arrays, and a top ZnO film, was consecutively fabricated by adjusting the supersaturation conditions using a metal-organic chemical vapor deposition (MOCVD) to utilize the vertically aligned ZnO nanowires as the oxygen sensors. The decrease of current flow through ZnO nanowire arrays increasing oxygen pressure showed the high potential for the application of the ZnO hybrid nanostructure to the oxygen sensors. In addition, it was confirmed that the oxygen sensing characteristics of this hybrid nanostructure were attributed to the defects near the surface of the nanowires.

Effectiveness of the Sensor using Lead Dioxide Electrodes for the Electrochemical Oxygen Demand (전기화학적 산소요구량 측정용 이산화납 전극 센서의 유효성)

  • Kim, Hong-Won;Chung, Nam-Yong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.575-581
    • /
    • 2012
  • The electrochemical oxygen demand (ECOD) is an additional sum parameter, which has not yet found the attention it deserves. It is defined as the oxygen equivalent of the charge consumed during an electrochemical oxidation of the solution. Only one company has yet developed an instrument to determine the ECOD. This instrument uses $PbO_2$-electrodes for the oxidation and has been successfully implemented in an automatic on-line monitor. A general problem of the ECOD determination is the high overpotential of electrochemical oxidations of most organic compounds at conventional electrodes. Here we present a new approach for the ECOD determination, which is based on the use of a solid composite electrodes with highly efficient electro-catalysts for the oxidation of a broad spectrum of different organic compounds. Lead dioxide as an anode material has found commercial application in processes such as the manufacture of sodium per chlorate and chromium regeneration where adsorbed hydroxyl radicals from the electro-oxidation of water are believed to serve as the oxidizing agent. The ECOD sensors based on the Au/$PbO_2$ electrode were operated at an optimized applied potential, +1.6 V vs. Ag/AgCl/sat. KCl, in 0.01 M $Na_2SO_4$ solution, and reduced the effect of interference ($Cl^-$ and $Fe^{2-}$) and an expended lifetime (more than 6 months). The ECOD sensors were installed in on-line auto-analyzers, and used to analyze real samples.

Fabrication of a Zirconia Oxygen Sensor Added with $Al_{2}O_{3}$ and Its Characteristics ($Al_{2}O_{3}$가 첨가된 지르코니아 산소센서의 제조 및 그 특성)

  • Sohn, Jeong-Duk;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.93-100
    • /
    • 1992
  • Sinterability, mechanical and electrical properties of yttria-stabilized zirconia(92 mole% $ZrO_{2}$+8 mole% $Y_{2}O_{3}$) doped with 0.5 mole% $SiO_{2}$ and $0{\sim}2.0 mole%{\;}Al_{2}O_{3}$ were studied as a function of $Al_{2}O_{3}$ addition. Sintered density increased with increasing $Al_{2}O_{3}$ addition up to 0.5 mole % but leveled off with further addition. Victors hardness is proportional to sintered density. The specimen with 0.5 mole% $Al_{2}O_{3}$ and 0.5 mole% $SiO_{2}$ exhibited the maximum electrical conductivity and revealed a maximum electromotive force for a given oxygen partial pressure. Experimental voltage curve of this oxygen sensor take on a sharper, more steplike transition at the stoichiometric A/F ratio than those of other commercial oxygen sensors.

  • PDF

A STUDY ON A CATALYTIC CONVERTER OBD BEFORE LIGHT-OFF

  • Yun, Seung-Won;Son, Geon-Seog;Lee, Kwi-Young
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.33-40
    • /
    • 2002
  • Increasingly stringent emission regulations of EU and CARB (California Air resource Board) require mandatory OBD (On Board Diagnostics) far the catalytic converters of a vehicle. It demands that MIL(Malfunction Indication Light) should be tuned on to inform the driver of catalytic converter failures. Currently dual oxygen sensor method Is widely used for the converter OBD. However, since it works only alter converter light-off, it has a serious limitation when applied to TLEV or more stringent emission regulations where more than 85% of total emission is coming out before converter light-off. In addition, a recent development in catalyst material. coating technology and additive catalysts leads to a much improved OSC (Oxygen Storage Capacity) after converter light-off, current methods are very difficult to determine levels of converter aging. Therefore, it is desired to develop an OSC detecting method before converter light-off to diagnose converter failures with higher reliability. In this study, OSCs of converters are measured by an absolute measuring method and a dynamic measuring method, and some of fundamental ideas are suggested about converter OBD before converter light-off. The converters are aged with two different aging methods; those are a furnace aging and an engine bench aging: to represent aging conditions in actual field applications. Dual oxygen sensor method at the lower temperature than light-off is also studied at a model gas bench with the converters. It is fecund that there is a certain point in temperature lower than light-off where difference due to aging level becomes maximum, thus a proper dynamic method to effectively monitor catalytic converters could be implemented fur the range lower than light-off temperatures. With this result, the aging level of converters is examined at an engine bench.

Sensitivity improvement of $CeO_2$ oxygen sensor by betterment of surface characteristics through chemical mechanical polishing process (CMP 공정을 통한 표면 특성 개선에 의한 $CeO_2$ 산소 센서 감도 향상 연구)

  • Jung, Pan-Gum;Jun, Young-Kil;Ko, Pil-Ju;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.65-65
    • /
    • 2007
  • Microstructure and surface roughness of the sensing materials should be improved to use them in advanced sensor applications because the uneven surface roughness degrades the light reflection, pattern resolution, and devices performance. Chemical mechanical polishing (CMP) processing was selected for improving the surface roughness of $CeO_2$ which is one of the well known materials for the oxygen gas sensors. Surface roughness and removal rate of spin coated $CeO_2$ thin films were examined with a change of CMP process parameters such as down force and table speed. The optimized process condition, reflected by the surface roughness with the hillock-free surface as well as the excellent removal rate with the good uniformity, was obtained. The effects of the improved surface roughness on the sensing property of $CeO_2$ thin films were also confirmed. The improved sensitivity of $CeO_2$ thin films for oxygen sensors were obtained after CMP process by the improved surface characteristics. Therefore, we conclude that sensing property of $CeO_2$ thin film is strongly dependent on the surface roughness of $CeO_2$ thin films by using CMP process.

  • PDF

Sensor Fault Detection and Analysis of Fault Status using Smart Sensor Modeling

  • Kim, Sung-Shin;Baek, Gyeong-Dong;Lee, Soo-Jin;Jeon, Tae-Ryong
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.207-212
    • /
    • 2008
  • There are several sensors in the liquid cargo ship. In the liquid cargo ship, we can get values from various sensors that are level sensor, temperature sensor, pressure sensor, oxygen sensor, VOCs sensor, high overfill sensor, etc. It is important to guarantee the reliability of sensors. In order to guarantee the reliability of sensors, we have to study the diagnosis of sensor fault. The technology of smart sensor is widely used. In this paper, the technology of smart sensor is applied to diagnosis of level sensor fault for liquid cargo ship. In order to diagnose sensor fault and find the sensor position, in this paper, we proposed algorithms of diagnosis of sensor fault using independent sensor diagnosis unit and self fault diagnosis using sensor modeling. Proposed methods are demonstrated by experiment and simulation. The results show that the proposed approach is useful. Proposed methods are useful to develop smart level sensor.