• Title/Summary/Keyword: oxygen flow rate

Search Result 689, Processing Time 0.027 seconds

Effect of Aeration and Agitation Conditions on the Production of Glucoamylase with Aspergillus niger No. PFST-38

  • Oh, Sung-Hoon;O, Pyong-Su;Lee, Cherl-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.3 no.4
    • /
    • pp.292-297
    • /
    • 1993
  • Aspergillus niger No. PFST-38 was grown on complex media in 30L agitated fermentors at various aeration rates and stirrer speeds. We could correlate the mixing time as a function of the Reynolds number and the apparent viscosity, as follows. ${\theta}_M=2.95\;\NRe^{-0.52},\;{\theta}_M=1.88\;{\eta_a}^{0.57}$ Also, the effects of the apparent viscosity (${\theta}_a$), the impeller rotational speed (N), the air flow rate ($V_s$), and the mixing time (${\theta}_M$) on the oxygen transfer coefficient, $K_L a$ were determined experimentally, and equated as follows. $K_La=12.04N^{0.88}Vs^{0.71}{n_a}^{-0.83},\;K_La=30.2N^{0.88}Vs^{0.71}{\theta_M}^{-1.45}$ $K_La$ increased as the agitation speed and the air flow rate increased. The rate of $K_La$ increase was dependent more on the rotational speed of impeller than on the air flow rate. The glucoamylase production increased with the increase of the agitation speed upto at 500 rpm and increased with the increase of air flow rate upto at 1.0 vvm. The values calculated from the above equation confirmed that the experimental maximum production of glucoamylase was achieved when the $K_La$ and the apparent viscosity of the broth were $260\;hr^{-1}$ and 1800 cps, respectively.

  • PDF

A Study on Combustion Characteristics of End-Burning Hybrid Propulsion System with the Various Fuel (End-burning 하이브리드 추진시스템의 연료에 따른 연소특성 연구)

  • Lee Seung-Chul;Kim Jin-Kon;Kim Soo-Jong;You Woo-Jun;Lee Jung-Pyo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.323-326
    • /
    • 2005
  • In this study, experimental studies were performed the combustion characteristics of end- burning hybrid propulsion system. PMMA, PE were used as fuel and gas oxygen as oxidizer. The regression rate depend on oxidizer flow rate also on thermodynamic properties of fuel. as result, empirical formula for regression rate was deduces with oxidizer flow rate and mass transfer coefficient B number.

  • PDF

A Study on the Combustion Properties of Single-Port Hybrid propulsion System with Various Fuel (Single port 하이브리드 추진 시스템의 연료에 따른 연소특성 연구)

  • You Woo-Jun;Kim Jin-Kon;Lee Jung-Pyo;Kim Soo-Jong;Lee Seung-Chul;Kuk Tae-Seung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.368-372
    • /
    • 2005
  • The variation of regression rate of single port hybrid rocket was studied with various fuel. As fuel, PE, PMMA were used and gas oxygen as oxidizer. The regression rate depends on but flow rates of oxidizer also thermodynamic properties of fuel. In this study, the empirical relation for regression rate of solid fuel were found with mass transfer coefficient(B number) and oxidizer flow rate.

  • PDF

Analysis of Flow on Grooving Corrosion at the Weld of a Carbon Steel pipe made by Electrical Resistance Welding (전기저항 용접강관의 홈부식에 미치는 유동 해석)

  • Kim, Yong;Jang, Hyeuk;Ryu, Duck-Hee;Kim, Jae-Seong;Lee, Bo-Young;Boo, Joon-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1-6
    • /
    • 2004
  • Lots of researches were gone already about grooving corrosion mechanism of ERW carbon steel pipe. But there is seldom study for water hammer happened by fluid and acceleration of corrosion rate by incresed flow velocity. Therefore, in this study carried out the analysis based on hydrodynamic and fracture mechanics. Analyzed stress that act on a pipe using ANSYS as a program, and also FLUENT and STAR-CD were used for flow phenomenon confirmation. As the result, fatigue failure is happened by water hammer and corrosion rate was increased because of turbulent flow.

  • PDF

The Cooling Performance of Thrust Chamber with Film Cooling (막냉각에 따른 추력실의 냉각 성능)

  • Kim, Sun-Jin;Jeong, Hae-Seung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.117-124
    • /
    • 2006
  • Experiments on film cooling were performed with a small scale rocket engine homing liquid oxygen (LOx) and Jet A-1(jet engine fuel). Film coolants(Jet A-1 and water) were injected through the film cooling injector. Film cooled length and the outside wall temperature of the combustor were determined for chamber pressure, and the different geometries(injection angle) with the flow rates of film coolant. The loss of characteristic velocity due to film cooling was determined for the case of film cooling with water and Jet A-1. As the coolant flow increases, the outside wall temperatures decrease but the decrease in the outside wall temperatures reduced over the 8 percent film coolant flow rate. The efficiency of characteristic velocity was decreased with the Increase of the film coolant flow rate.

Preliminary Study of a New Extracorporeal Membrane Oxygenator Development When Using Pulsatile Flow

  • Lee, Sa-Ram;Lee, Kyung-Soo;Jung, Jae-Hoon;Mun, Cho-Hay;Min, Byoug-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.387-391
    • /
    • 2007
  • An oxygenator is a very important artificial organ and widely used for patients with lung failure or during open heart surgery. Although an oxygenator has been widely studied worldwide to enhance its efficiency, studies on oxygenators, in particular when using a pulsatile blood flow, are domestically limited. Therefore, a new oxygenator was developed in the lab and animal experimental results are described in the paper. The oxygenator is composed of polycarbonate housing and polypropylene hollow fibers. It has a total length of 400 mm and a surface area of $1.7 m^2$. The animal experiment lasted for 4 hours. The blood flow rate was set to 2 L/min and a pulsatile blood pump, T-PLS (Twin-Pulse Life Support), was used. Samples were drawn at the oxygenator's inlet and outlet. The total hemoglobin (Hb), saturation oxygen ($sO_2$), and partial oxygen pressure ($pO_2$), partial $CO_2$ pressure ($pCO_2$), and plasma bicarbonate ion concentration ($HCO_3^-$) were measured. The oxygen and carbon dioxide transfer rates were also calculated based on the experimental data in order to estimate the oxygenator's gas transfer efficiency. The oxygen and carbon dioxide transfer rates were $16.4{\pm}1.58$ and $165.7{\pm}10.96 mL/min$, respectively. The results showed a higher carbon dioxide transfer rate was achieved with the oxygenator. Also, the mean inlet and outlet blood pressures were 162.79 and 137.92 mmHg, respectively. The oxygenator has a low pressure drop between its inlet and outlet. The aim of own preliminary study was to make a new oxygenator and review its performance when applying a pulsatile blood pump thus, confirming the possibility of a new oxygenator suitable for pulsatile flow.

Effects of Deposition Conditions on the Deposition rate and physical properties of $SnO_2$ film produced by CVD (CVD에 의한 $SnO_2$ Film 제조시 증착조건이 Film의 증착속도 및 물리적 성질에 미치는 영향)

  • Lee, Dong-Yun;Lee, Sang-Rae
    • Journal of the Korean institute of surface engineering
    • /
    • v.18 no.3
    • /
    • pp.116-124
    • /
    • 1985
  • Chemical vapor deposition of $SnO_2$ on Pyrex glass substrate has been investigated using $SnCl_4$ and Oxygen at relatively low temperatures(300-500$^{\circ}C$). The critical flow rate, which delineated the surface reaction controlled region from the mass transfer controlled region, was increased with deposition temperature. The apparent activation energy obtained in surface reaction controlled region was about 6Kcal/mole. The results show that deposition rate, electrical conductivity and transmittance were affected mainly by partial pressure of $SnCl_4$, but little by partial pressure f oxygen. The % transmission of 5000A-thick $SnO_2$ film was about 90% in visible spectrum region and sheet resistance was varied in 0.1-10${\Omega}$ per square shaped portion of the outer surface of the oxide.

  • PDF

A Numerical Study of Cathode Block and Air Flow Rate Effect on PEMFC Performance (고분자전해질 연료전지의 환원극 블록과 공기 유량 영향에 대한 전산 해석 연구)

  • Jo, Seonghun;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.96-102
    • /
    • 2022
  • Reactants of PEMFC are hydrogen and oxygen in gas phases and fuel cell overpotential could be reduced when reactants are smoothly transported. Numerous studies to modify cathode flow field design have been conducted because oxygen mass transfer in high current density region is dominant voltage loss factor. Among those cathode flow field designs, a block in flow field is used to forced supply reactant gas to porous gas diffusion layer. In this study, the block was installed on a simple fuel cell model. Using computational fluid dynamics (CFD), effects of forced convection due to blocks on a polarization curve and local current density contour were studied when different air flow rates were supplied. The high current density could be achieved even with low air supply rate due to forced convection to a gas diffusion layer and also with multiple blocks in series compared to a single block due to an increase of forced convection effect.

A Study on the Effect of Recirculated Exhaust Gas with Scrubber EGR System upon Exhaust Emissions in Diesel Engines (디젤기관의 배기 배출물에 미치는 스크러버형 EGR 시스템 재순환 배기의 영향에 관한 연구)

  • Bae, Myung-Whan;Ha, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1247-1254
    • /
    • 2000
  • The effects of recirculated exhaust gas on the characteristics of $NO_x$ and soot emissions under a wide range of engine load have been experimentally investigated by a water-cooled, four-cylinder, indirect injection, four cycle and marine diesel engine operating at two kinds of engine speeds. The simultaneous control of $NO_x$ and soot emissions in diesel engines is targeted in this study. The EGR system is used to reduce $NO_x$ emissions, and a novel diesel soot removal device with a cylinder-type scrubber for the experiment system which has 6 water injectors(A water injector has 144 nozzles in 1.0 mm diameter) is specially designed and manufactured to reduce the soot contents in the recirculated exhaust gas to intake system of the engines. The intake oxygen concentration and the mean equivalence ratio calculated by the intake air flow and fuel consumption rate, and the exhaust oxygen concentration measured are used to analyse and discuss the influences of EGR rate on $NO_x$ and soot emissions. The experiments are performed at the fixed fuel injection timing of $15.3^{\circ}$ BTDC regardless of experimental conditions. It is found that $NO_x$ emissions are decreased and soot emissions are increased owing to the drop of intake oxygen concentration and exhaust oxygen concentration, and the rise of equivalence ratio as the EGR rate rises.

Pulmonary Hemodynamic Alterations Following Radical Hilar Stripping (폐문부박리가 폐혈류 역학에 미치는 영향)

  • Kwack, Moon Sub;Lee, Hong Kyun
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.20-26
    • /
    • 1976
  • Author has performed experimental study on hemodynamic changes of lung following radical hilar stripping and contralateral pulmonary artery ligation. In view of hemodynamic changes in group 1 (right pulmonary artery ligation only) and group 2(left hilar stripping+right pulmonary artery ligation). group 2 showed remarkable decrease rate in oxygen uptake (P<0.001) and total pulmonary blood flow(P<0.001), and the more increase rate in mean pulmonary artery pressure(P<0.02) and total pulmonary vascular resistance (P<0.001). Meanwhile, the decrease percent of left lung vascular resistance was lower than group 1(P<0.001). The hemodynamic changes in group 1 returned to control range two weeks later. In the group 2, two dogs were expired as a result of atelectasis and pulmonary hypertension. Among allying 8 dogs, five months after operation, follow up studies performed in two dogs, which showed normal pulmonary hemodynamics similar to preoperative data. The altered blood gas values and decreased oxygen uptake are more remarkable in denervated lung, which may due to pulmonary hypertension and partly retained more secretion in bronchial trees than usual. Important factors of raising pulmonary vascular resistance and pulmonary artery pressure are considered as the increased blood flow to remaining left lung and dysfunction of pulmonary vascular bed to accept the increased blood flow after denervation. Loss of nerve innervation had a influence, to some extent, to the decrease of oxygen uptake and the increase of pulmonary vascular resistance and pulmonary artery pressure. There can be little question that denervation does impair the pulmonary hemodynamics, however, intact pulmonary nerve innervation is not absolutely essential for survival of the animal.

  • PDF