• 제목/요약/키워드: oxygen flow rate

검색결과 689건 처리시간 0.025초

적출활동심장에서 Prostacyclin [PGI2]의 심근보호효과 (Effects of Prostacyclin [PGI2] on Myocardial Protection in the Isolating Working Heart Model)

  • 이길노;김규태
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.643-654
    • /
    • 1987
  • The effect of prostacyclin[PGI, ] on myocardial preservation during global ischemia was studied in the isolating working rabbit heart model. Forty hearts underwent a 15 minute period of retrograde nonworking perfusion with Krebs-Henseleit buffer solution [37*C] and were switched over to the working mode for 15 minutes. After baseline measurement of heart rate, peak aortic pressure, aortic flow, and coronary flow, all hearts were subjected to 60 minutes of ischemic arrest at 10*C induced with St. Thomas Hospital cardioplegic solution: Group I had single dose cardioplegia, Croup II double dose, Croup III oxygenated double dose, and Group IV single dose with PCI, infusion [10ng/min./gm heart weight]. Hearts were then revived with 15 minute period of nonworking reperfusion at normothermia, followed by 30 minutes of working perfusion. Repeat measurements of cardiac function were obtained and expressed as a percent of the preischemic baseline values. Oxygen content of arterial perfusate and coronary effluent was measured by designed time interval. Leakage of creatine kinase was determined during post-ischemic reperfusion period. Finally wet hearts were weighed and placed in 120*C oven for 36 hours for measurement of dry weight. In the PGI, treated group [IV], heart rate increased consistently throughout the period of reperfusion from 100*5.0% [p<0.001] to 107*6.2% [p<0.001]. The percent recovery of aortic flow showed 95*5.7% [p<0.001] at the first 3 minute and full recovery through the subsequent time. Coronary flow was augmented significantly in the 3 minute [96*6.2%, p<0.001] and then sustained above baseline values. Among the Croup I, II, and III, all hemodynamic values were significantly below preischemic levels. PGI2 relatively increased oxygen delivery [1.22*0.19ml/min, p<0.001] and myocardial oxygen consumption [0.90*0.13ml/min, p<0.001] during reperfusion period. Leakage of creatine kinase in the PGI2 group was 9.3*1.58IU/15min [p<0.001]. This was significantly lower than Group I [33.0*2.68 IU/15min]. The water content of PCI2 treated hearts [81*0.9%, p<0.001] was also lower than the other groups.

  • PDF

왕복요동 교반조의 자유 표면에서의 산소흡수속도 (Oxygen Transfer Rate from Liquid Free Surface in Reciprocally Shaking Vessel)

  • 고승태
    • Korean Chemical Engineering Research
    • /
    • 제59권2호
    • /
    • pp.276-280
    • /
    • 2021
  • 왕복 요동 교반조의 액체 표면에서의 산소 전달 속도에 대해 연구하였다. 왕복 요동 교반조의 소요 동력은 선회요동 교반조와는 달리 요동 주파수에 비례하지 않았으며, 교반조 내의 유동양상이 선회요동의 선회류와는 다른 좌우 물결류인 관계로 어떤 진동수에서 갑자기 액면이 크게 흔들리며 움직이는 양상을 보이며. 3 s-1 이상의 요동 주파수부터는 소요 동력이 선회요동 교반조보다 적어지는 등 요동 주파수가 소요 동력에 미치는 영향은 매우 복잡하였지만, 생성되는 회전류의 범위에서의 왕복 요동 교반조 소요 동력은 회전 요동 교반조에 대해 보고된 식으로 상관시킬 수 있었다. 왕복요동 교반조에서의 kLa (물질이동 용량계수) 역시 교반 소요 동력이 단순한 형태로 소비되지 않았기 때문에 주파수의 증가에 따라 선형으로 증가하는 선회요동 교반조의 kLa와는 달리 복잡한 형태로 증가하였다. 왕복요동 교반의 kLa가 선회요동 교반의 kLa 보다 컸으며, kLa 값이 커질수록 그 차이도 급격히 커졌다. 결과적으로 왕복 요동에서의 산소 전달 속도는 회전 요동보다 컸으며, 단위 부피당 소요 동력과 상관시킬 수 있었다.

Effect of Ambient Gases on the Characteristics of ITO Thin Films for OLEDs

  • Lee, Yu-Lim;Lee, Kyu-Mann
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권6호
    • /
    • pp.203-207
    • /
    • 2009
  • We have investigated the effect of ambient gases on the structural, electrical, and optical characteristics of ITO thin films intended for use as anode contacts in OLED (organic light emitting diodes) devices. These ITO thin films are deposited by radio frequency (RF) magnetron sputtering under different ambient gases (Ar, Ar+$O_2$, and Ar+$H_2$) at $300{^{\circ}C}$. In order to investigate the influences of the oxygen and hydrogen, the flow rate of oxygen and hydrogen in argon mixing gas has been changed from 0.5 sccm to 5 sccm and from 0.01 sccm to 0.25 sccm, respectively. The intensity of the (400) peak in the ITO thin films increased with increasing $O_2$, flow rate whilst the (400) peak was nearly invisible in an atmosphere of Ar+$H_2$. The electrical resistivity of the ITO thin films increased with increasing $O_2$ flow rate, whereas the electrical resistivity decreased sharply under an Ar+$H_2$ atmosphere and was nearly similar regardless of the $H_2$ flow rate. The change of electrical resistivity with changes in the ambient gas composition was mainly interpreted in terms of the charge carrier mobility rather than the charge carrier concentration. All the films showed an average transmittance of over 80% in the visible range. The OLED device was fabricated with different ITO substrates made with the configuration of ITO/$\alpha$-NPD/DPVB/$Alq_3$/LiF/Al in order to elucidate the performance of the ITO substrate. Current density and luminance of OLED devices with ITO thin films deposited in Ar+$H_2$ ambient gas is the highest among all the ITO thin films.

Effects of Sodium Cyanide (NaCN) on the Endogenous Rhythm of the Oxygen Consumption Rate in the Black Rockfish Sebastes schlegeli

  • Kim, Wan-Soo;Kim, Jong-Wook;Lee, Jae-Hak;Huh, Sung-Hoe
    • Ocean Science Journal
    • /
    • 제43권2호
    • /
    • pp.107-113
    • /
    • 2008
  • Laboratory bioassays were conducted to test the acute toxicity effects of sudden exposure to sodium cyanide (NaCN) on the endogenous rhythm of the oxygen consumption rate (OCR) in the black rockfish Sebastes schlegeli. The OCR of the black rockfish(n = 14, total length = $20.4{\pm}1.16\;cm$, wet weight = $158{\pm}25\;g$) was measured with an automatic intermittent-flow-respirometer. OCR decreased significantly when experimental fish were exposed to NaCN. When exposed to 10 ppb NaCN, fish were able to recover their OCR rhythmic activities. When fish were exposed to 20 ppb, however, the metabolic activity rhythms were not recovered. These results suggest that exposure to NaCN concentrations over 20 ppb cause severe physiological damage to the endogenous rhythms of black rockfish.

배양 조건이 Bacillus thuringiesis 독소단백질의 생산에 미치는 영향 (Effect on the Production of Toxin Protein of Bacillus thuringiesis by Culture Conditions)

  • 김태완;김태환;유용만
    • 농약과학회지
    • /
    • 제18권4호
    • /
    • pp.358-363
    • /
    • 2014
  • 신규 병원성세균 Bacillus thuringiensis CAB565, 566균주를 이용한 산업배지에서의 배양조건에 따른 독소단백질의 차이를 확인하였다. 포도당, 효모추출물 등으로 구성된 산업배지의 산소 전달 속도를 확인하고자 소형배양기에서 임펠러와 배지 농도에 따른 산소전달계수(KLa)의 차이를 확인하였다. 교반기의 통기량이 많을수록 그리고 배지 농도가 높아질수록 산소전달계수(KLa) 값이 상승하였다. 하지만 교반속도는 200 rpm에서 가장 효율적이었고, 교반속도가 상승할수록 효과가 떨어졌다. Microsparger를 이용하여 배양 중 단계적으로 통기속도를 높여 배지내 용존산소농도를 50% 이상으로 유지시켜 배양한 결과 생균수는 배양 후 16시간, 포자수는 54시간에 최대의 농도값을 보였다. 그 결과, B.t. CAB565의 생균수는 $2.3{\times}10^{10}cell/ml$, 포자수는 $1.9{\times}10^{10}spore/ml$ 그리고 B.t. CAB566의 생균수는 $1.8{\times}10^{10}cell/ml$, 포자수는 $1.4{\times}10^{10}spore/ml$를 보였다. 탄소원의 농도는 포도당의 농도가 5%일 때, 세포성장에 가장 유리한 것으로 조사되었다.

The Experiments for the Enhancement of Regression Rate of Hybrid Rocket Fuel

  • Shin Kyung-Hoon;Lee Changjin;Yu Yung H.
    • Journal of Mechanical Science and Technology
    • /
    • 제19권10호
    • /
    • pp.1939-1949
    • /
    • 2005
  • Many studies have been conducted to increase regression rate of solid fuel in hybrid rocket. One of them resorts to swirl flow since it can extend the residence time of oxidizer in the fuel grain. Also, metal wires may lead to increase the regression rate of solid fuel as shown in solid propellants. In this study, a series of experiments was designed to investigate the enhancement of regression rate of solid fuel by embedded metal wires and by fuel port grain. And fuel port was designed with a helical configuration to attempt to induce swirl flow. PMMA with gaseous oxygen is the solid fuel used for investigation. Test results showed that embedded metal wires turned out to be ineffective method because only $3-4\%$ increases in regression rate were observed. However, fuel port grain configuration yields higher burning performance of up to $50\%$ increase in regression rate. Also pitch number as well as total impulse was found to be a design variable.

Corrosion Behavior of Stainless Steel 316 for Carbon Anode Oxide Reduction Application

  • Jeon, Min Ku;Kim, Sung-Wook;Choi, Eun-Young
    • 방사성폐기물학회지
    • /
    • 제18권2호
    • /
    • pp.169-177
    • /
    • 2020
  • Here, the stability of stainless steel 316 (SS-316) was investigated to identify its applicability in the oxide reduction process, as a component in related equipment, to produce a complicated gas mixture composed of O2 and Cl2 under an argon (Ar) atmosphere. The effects of the mixed gas composition were investigated at flow rates of 30 mL/min O2, 20 mL/min O2 + 10 mL/min Cl2, 10 mL/min O2 + 20 mL/min Cl2, and 30 mL/min Cl2, each at 600℃, during a constant argon flow rate of 170 mL/min. It was found that the corrosion of SS-316 by the chlorine gas was suppressed by the presence of oxygen, while the reaction proceeded linearly with the reaction time regardless of gas composition. Surface observation results revealed an uneven surface with circular pits in the samples that were fed mixed gases. Thermodynamic calculations proposed the combination of Fe and Ni chlorination reactions as an explanation for this pit formation phenomenon. An exponential increase in the corrosion rate was observed with an increase in the reaction temperature in a range of 300 ~ 600℃ under a flow of 30 mL/min Cl2 + 170 mL/min Ar.

증착 온도 및 수소 유량에 따른 IZO 박막의 구조적 및 전기적 특성 (Structural and Electrical Characteristics of IZO Thin Films Deposited at Different Substrate Temperature and Hydrogen Flow Rate)

  • 한성호;이규만
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.33-37
    • /
    • 2013
  • In this study, we have investigated the effect of the substrate temperature and hydrogen flow rate on the characteristics of IZO thin films for the organic light emitting diodes (OLED) devices. For this purpose, IZO thin films were deposited by RF magnetron sputtering at room temperature and $300^{\circ}C$ with various $H_2$ flow rate. In order to investigate the influences of the oxygen, the flow rate of hydrogen in argon mixing gas has been changed from 0.1sccm to 0.9sccm. IZO thin films deposited at room temperature show amorphous structure, whereas IZO thin films deposited at $300^{\circ}C$ show crystalline structure having an (222) preferential orientation regardless of $H_2$ flow rate. The electrical resistivity of IZO film decreased with increasing flow rate of $H_2$ under Ar+$H_2$. The change of electrical resistivity with increasing flow rate of $H_2$ was mainly interpreted in terms of the charge carrier concentration rather than the charge carrier mobility. The electrical resistivity of the amorphous-IZO films deposited at R.T. was lower than that of the crystalline-IZO thin films deposited at $300^{\circ}C$. The increase of electrical resistivity with increasing substrate temperature was interpreted in terms of the decrease of the charge carrier mobility and the charge carrier concentration. All the films showed the average transmittance over 83% in the visible range.

산소부화연소에서 Co2 첨가에 대한 연소 특성 (Characteristics for Effects of Co2 Addition to Oxygen-Enriched Combustion)

  • 김한석;김호근;안국영;김용모
    • 대한기계학회논문집B
    • /
    • 제28권1호
    • /
    • pp.9-15
    • /
    • 2004
  • $CO_2$ is a well-known green house gas as well as the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. Among the method for reducing $CO_2$ emission, oxygen-enriched combustion has been proposed. Because its adiabatic flame temperature is relatively too high, existing facilities must be changed or the flame temperature in the combustion zone should be reduced. The combustion characteristics, composition in the flame zone, temperature profile and emission gases were investigated experimentally for the various oxygen-enriched ratios(OER) by the addition of $CO_2$, under constant $O_2$ flow rate. Results showed that the reaction zone was quenched and broadened as the addition of $CO_2$ was increased. The emission of NOx in flue gas was decreased as decreasing temperature in reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the addition of $CO_2$ was increased, the composition of CO in the flame zone was increased due to the increase of reaction rate by increasing mixing effect of oxidant/fuel at OER=0%, but the composition of CO was decreased by quenching effect at OER=50% and 100%.

랜스 거동 분석을 이용한 전로 내부 상태 감시 (Condition Monitoring of Internal State of Oxygen Converter Chamber Using Lance Behavior Analysis)

  • 임은섭;김흥묵;김승곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.658-663
    • /
    • 2000
  • Slopping phenomena deteriorate the productivity and the stability of operation in oxygen converter process. To predict and prevent that, it needs reliable perception of the internal state of the oxygen converter chamber. Equipment was developed to measure the dynamic and static behavior of the oxygen-blowing lance 3-dimensionally and the measured signal is analyzed in relation to slopping phenomena. It was found that the behavior of the lance is strongly correlated to the change of slag foam height and the instability of molten steel behavior. So slopping phenomena can be predicted by simultaneously analyzing the measured behavior of the lance and the control factors such as the flow rate of oxygen and the height of lance.

  • PDF