• 제목/요약/키워드: oxygen control

검색결과 1,968건 처리시간 0.024초

고압 산소 요법의 뇌경색 환자 치료 효과에 대한 연구 (A Case-Control Study on the Effect of Hyperbaric Oxygen Therapy on Cerebral Infarction Patients)

  • 오민규;김동진;윤혜연;신현수
    • 대한한방내과학회지
    • /
    • 제29권3호
    • /
    • pp.675-683
    • /
    • 2008
  • Objectives : This study was designed to examine the effects of hyperbaric oxygen therapy on cerebral infarction. Methods : Fifty-five patients with acute or subacute cerebral infarction were classified into two groups, the study group and control group. The study group was treated by hyperbaric oxygen therapy(HBOT) for 2 weeks(5 times/week) and the control group wasn't treated by HBOT. We compared the score of National Institutes of Health Scale(NIHSS scale) between two groups. We subdivided the study group by TOAST classification and onset stage, and compared the results. All of this data was analyzed by statistical method. Results : The study group patients who were treated by hyperbaric oxygen therapy saw more improvement than the control group patients in NIHSS score, and there was significant consideration. Among the study group patients, we saw more improvement during the first week period than in the course of the second week, and there was significant consideration. Conclusion : These results suggest that hyperbaric oxygen therapy(HBOT) could be a useful medical treatment to treat cerebral infarction. Further studies are needed on more cases to make sure that hyperbaric oxygen therapy (HBOT) is surely effective for cerebral infarction.

  • PDF

Clark Cell을 이용한 ppb단위 용존산소 측정기술개발 (Development of pub Level Dissolved Oxygen Measuring Technology using Clark Cell)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.375-381
    • /
    • 2002
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to pub units. This method, called polarograph method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.

Removal of Dissolved Oxygen from the Make-up Water of NPP Using Membrane-based Oxygen Removal System

  • Chung, Kun-Ho;Kang, Duck-Won;Hong, Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.541-547
    • /
    • 1999
  • Corrosion control, in the end-shield cooling system of Wolsung Nuclear Power Plant, is directly related to the control of dissolved oxygen (DO). The current method, being used to deoxygenate the end-shield cooling water, is a chemical treatment by addition of reducing agent, hydrazine, to react with DO. This method has several limitations including high reaction temperature of hydrazine , unwanted explosive hydrogen gas production, and its intrinsic harmful property. A new approach to remove DO using a membrane-based oxygen removal system (MORS) was tried to overcome limitations of the hydrazine treatment. The DO removal efficiency of the MORS was found to be in the range 87% to 98%: The higher vacuum, the lower water flow rate and the higher water temperature tend to increase the DO removal efficiency.

  • PDF

Clark Cell을 이용한 ppb Level 용존산소 측정기술 개발에 관한 연구 (A Study on the Development of ppb Level Dissolved Oxygen Measuring Technology using Clark Cell)

  • 정경열;이후락;동은석;이수태;류길수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.197-201
    • /
    • 2001
  • Measuring of the dissolved oxygen is widely used for the environmental control of natural waters, sewage waste treatment, medical and biochemical studies, soil husbandry, food and drug process control, and prevention of corrosion in boilers. Especially, a power plants need special management for preventing accidents from corrosion, therefore, it is essential to measure the concentration of dissolved oxygen in real-time. In this paper we present a method of measuring dissolved oxygen very accurately up to ppb units. This method, called polarographic method, is based on the measures of the electric current generated by the oxidation process in cathode and de-oxidation process in anode, assuming that the amount of the current is proportional to the density of dissolved oxygen.

  • PDF

Robust Nonlinear Control of Air-to-Fuel Ratio in Spark Ignition Engines

  • Myoungho Sunwoo;Paljoo Yoon;Park, Seungbum;Lee, Wootaik
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.699-708
    • /
    • 2001
  • This paper presents a new approach to the AFR (Air-to-Fuel Ratio) control problem, which is based on the wide-band oxygen sensor output. The dedicated nonlinear controller is based on the feedback lineaization technique. It is well known that the feedback linearizing control technique requires an exact model of the plant for the cancellation of plant nonlinearities. A sliding mode control scheme is applied which can effectively compensate the modeling uncertainties. The measurement time delay of an oxygen sensor limits the gain of the feedback controller. Hence, time delay compensation procedure is necessary for the improvement of control performance. The Smith predictor is adopted to compensate the effects of time delay. The simulation and experimental results show that the proposed controllers can effectively reduce the transient peaks of AFR in spite of fast tip-in and tip-out maneuvers of the throttle.

  • PDF

노리개젖꼭지 제공이 미숙아의 심박동수, 산소포화도 및 행동상태에 미치는 효과 (Effects of Nonnutritive Sucking on Heart Rate, Oxygen Saturation and Behavioral State in Premature Infants)

  • 박진희;박호란
    • Child Health Nursing Research
    • /
    • 제13권3호
    • /
    • pp.299-307
    • /
    • 2007
  • Purpose: To investigate the effect of nonnutritive sucking(NNS) on the heart rate, oxygen saturation, and behavioral state of premature infants. Method: From December 15, 2004 to February 15, 2005, 20 premature infants hospitalized in the neonatal intensive care units were assigned to an experimental group (10), or a control group (10). Circular pacifiers for premature infants (Johnson, U.S.A.), which had been packed with $2{\times}2$ gauzes to create a vacuum, were used for 5 minutes, one hour after feeding for 5 days. Heart rates and oxygen saturation were checked every minute for 10 minutes once a day and behavioral states were monitored through video recording at the same time. Results: Changes in heart rate, oxygen saturation and behavioral state were found to show significant differences between the experimental group and the control group according to the point in time, and interactions were found between the group and the point of time. However, for behavioral state, no significant difference was found between the experimental group and the control group after the NNS was removed. Conclusion: From the results of this study it is possible to conclude that NNS is a positive intervention to bring about increased oxygen saturation and soothed behavioral state for premature infants.

  • PDF

액체산소를 사용하는 발사체 산화제 및 산화제 지상공급시스템의 품질관리 (Quality control for the liquid oxygen as the oxidizer of launcher and the liquid oxygen filling system as ground facility)

  • 김지훈;유병일;강선일;오승협
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.309-312
    • /
    • 2009
  • 성공적인 발사나 시험 운용을 위해서는 여러 가지 위험 요소들을 사전에 제거하여야 한다. 오염된 추진제 사용은 발사 혹은 시험을 실패하게 하는 원인들 중 하나이다. 특히 액체산소를 산화제로 사용하는 발사체 및 공급시스템의 경우 기계적 불순물, 유지분, 수분 등의 오염원들로 청정상태를 유지하지 못할 경우 예기치 못한 화재나 폭발의 위험도가 높아지게 된다. 본 논문에서는 이러한 오염원들을 제거하고 시스템을 청결하고 안전한 상태로 유지하기 위한 방법을 제시하고 그 적용결과 및 교훈을 정리해 보았다.

  • PDF

유가식 생물반응기에서의 용존산소농도 및 비성장속도의 제어 (Control of dissolved Oxygen Concentration and Specific Growth Rate in Fed-batch Fermentation)

  • 김창겸;이태호;이승철;장용근;장호남
    • 한국미생물·생명공학회지
    • /
    • 제21권4호
    • /
    • pp.354-365
    • /
    • 1993
  • A novel control method with automatic tuning of PID controller parameters has been developed for efficient regulation of dissolved oxygen concentration in fed-batch fermentations of Escherichia coli. Agitation speed and oxygen partial pressure in the inlet gas stream were chosen to be the manipulated variables. A heuristic reasoning allowed improved tuning decisions from the supervision of control performance indices and it coule obviate the needs for process assumptions or disturbance patterns. The control input consisted of feedback and feedforword parts. The feedback part was determined by PID control and the feedforward part is determined from the feed rate. The proportional gain was updated on-line by a set of heuristics rules based on the supervision of three performance indices. These indices were output error covariance, the average value of output error, and input covariance, which were calculated on-line using a moving window. The integral and derivative time constants were determined from the period of output response. The specific growth rate was maintained at a low level to avoid acetic acid accumulation and thus to achieve a high cell density. The specific growthe rate was estimated from the carbon dioxide evolution rate. In fed-batch fermentation, the simutaneous control of dissolved oxygen concentration (at 0.2; fraction of saturated value) and specific growth rate (at 0.25$hr^{-1}$) was satisfactory for the entire culture period in spite of the changes in the feed rate and the switching of control input.

  • PDF

발효기 하드웨어 변환을 이용한 용존산소 제어 (Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • 제15권3호
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF

일산화탄소 폭로후 고압산소 투여가 흰쥐 심장에서의 malondialdehyde 함량과 산소유리기 반응에 미치는 영향 (Effects of Hyperbaric Oxygen Treatment on the Malondialdehyde Level and Oxygen Free Radical Reactions in the Heart of the Rats Exposed to Carbon Monoxide)

  • 신인철;고현철;하지희
    • Biomolecules & Therapeutics
    • /
    • 제6권1호
    • /
    • pp.9-13
    • /
    • 1998
  • ln an attempt to define the effects of hyperbaric oxygen treatment on the lipid peroxidation and oxygen See radical reactions in rats exposed to carbon monoxide, we studied malondialdehyde(MDA) level and activities of catalase and superoxide dismutase in the heart of the rats exposed to carbon monoxide. Male Sprague-Dawley albino rats weighing 240 to 260gm were used. Experimental groups consist of Control group (=breathing with air), HBO group(=exposed to hyperbaric oxygen(HBO, 3ATA, 100%) after air breath), CO group(=exposed to CO(3,970 ppm) after air breath), CO-Air group(=exposed to CO after air breath followed by air breath) and CO-HBO group(=exposed to CO after ai. breath followed HBO treatment). The CO group showed significantly higher MDA level, catalase activity and SOD activity as compared to that of control group. The CO-HBO group showed significantly lower MDA level as compared to that of CO group, and did not show significantly lower catalase activity and SOD activity as compared to that of CO group. These results suggest that the excessive oxygen free radicals is an important determinant in pathogenesis of Co-induced cardiotoxicity and HBO inhibits the lipid peroxidation caused by excessive oxygen free radicals in the heart of the rats exposed to carbon monoxide.

  • PDF