• Title/Summary/Keyword: oxygen

Search Result 15,928, Processing Time 0.044 seconds

The Preparation of Sol-Gel Derived Aminoalkoxysilane Films and its Application for Oxygen Barrier (솔-젤법을 이용한 aminoalkoxysilane 산소차단필름의 제조)

  • Kim, Hyun-Joon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.3 s.16
    • /
    • pp.17-21
    • /
    • 2006
  • The oxygen barrier films were formed on poly(ethylene terephthalate) (PET) substrate by a sol-gel process using aminoalkoxysilanes. The coating layers were characterized by FT-IR and SEM. The oxygen permeability coefficients of coating films were measured by variable volume method, and then the influences of solvent ratio in sol and film drying temperature on the oxygen barrier properties were investigated. The aminoalkoxysilane coating films exhibited much higher oxygen barrier properties than PET film. The oxygen permeability coefficient of the film coated with each of APTEOS and APTMOS was measured to be $2.96{\times}10^{-6}$ and $3.05{\times}10^{-5}\;GPU$, respectively, while that of PET film was $1.16{\times}10^{-4}\;GPU$.

  • PDF

Effects of Saengmaegsan Extract on Cultured Myocardial Cells induced by Oxygen Tension (산소분압(酸素分壓)에 의한 심근세포변화(心筋細胞變化)에 미치는 생맥산(生脈散)의 효과(效果))

  • Shin, Sun-Ho;Ryu, Do-Gon;Moon, Byung-Sun
    • The Journal of Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.100-111
    • /
    • 1998
  • This study is designed to investigate the effects of Saengmaegsan extract on cultured myocardial cell sheets affected by oxygen tension change. The results were as follows : 1. Saengmaegsan meaningfully restored the cellular activity decrease in the cultured myocardial cells affected by high oxygen tension. 2. Saengmaegsan meaningfully lessened the degree of total protein decrease in the myocardial cells caused by high oxygen tension. 3. Saengmaegsan meaningfulJy refrained from syntetic decrease of 4-hydroxyproline in both low oxygen tension group and high oxygen tension group.

  • PDF

Corrosion Characteristics of HT-9 in 500℃ and 650℃ Pb-Bi Liquid Metal

  • Song, T.Y.;Cho, C.H.
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.94-98
    • /
    • 2006
  • The next generation nuclear power reactor will use Pb-Bi as the cooling material. The steel structure materials such as HT-9 used in the reactor suffer from corrosion when they are exposed to high temperature Pb-Bi. Therefore corrosion should be prevented to use Pb-Bi as the coolant material without any safety problem. One method is to control the oxygen content in Pb-Bi. An appropriate amount of oxygen in Pb-Bi can produce a thin oxide layer on steel, and this layer protects the steel from corrosion attack. Since the required oxygen content in Pb-Bi is in the range of $10^{-5}$ to $10^{-7}$ wt%, this small oxygen content can be controlled by flowing a mixture of hydrogen gas and water vapor. The stagnant corrosion test of HT-9 samples was performed by controlling the oxygen content up to 2,000 hours. The corrosion behavior of HT-9 was analyzed at the temperatures of $500^{\circ}C$ and $650^{\circ}C$ with a reduced condition and a oxygen content of $10^{-6}$ wt%.

RF-Sputted Vanadium Oxide Thin Films:Effect of Oxygen Partial Pressure on Structural and Electrochemical Properties

  • Park, Yong Jun;Park, Nam Gyu;Ryu, Gwang Seon;Jang, Sun Ho;Park, Sin Jong;Yun, Seon Mi;Kim, Dong Guk
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.9
    • /
    • pp.1015-1018
    • /
    • 2001
  • Vanadium oxide thin films with thickness of about 2000 $\AA$ have been prepared by radio frequency sputter deposition using a V2O5 target in a mixed argon and oxygen atmosphere with different Ar/O2 ratio ranging from 99/1 to 90/10. X-ray diffraction and X-ray absorption near edge structure spectroscopic studies show that the oxygen content higher than 5% crystallizes a stoichiometric V2O5 phase, while oxygen deficient phase is formed in the lower oxygen content. The oxygen content in the mixed Ar + O2 has a significant influence on electrochemical lithium insertion/deinsertion property. The discharge-charge capacity of vanadium oxide film increases with increasing the reactive oxygen content. The V2O5 film deposited at the Ar/O2 ratio of 90/10 exhibits high discharge capacity of 100 ${\mu}Ah/cm2-{\mu}m$ along with good cycle performance.

The Oxygen Barrier Properties of 3-aminopropyltrimethoxysilane (APTMOS) Coatings on PET Film (3-aminopropyltrimethoxysilane(APTMOS)을 코팅한 PET 필름의 산소차단성 연구)

  • Lee, Sung-Koo;Kim, Hyun-Joon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 2009
  • The oxygen barrier films were formed on poly(ethylene terephthalate) (PET) substrate by a sol-gel process using 3-aminoproprytrimethoxysilane (APTMOS). The effects of solvent type, coating times and incorporation of fumed silica on oxygen permeability coefficient were investigated. The APTMOS coating film prepared from methanol as a solvent exhibited higher oxygen barrier properties than that using THF. The oxygen permeability coefficient of coated film with APTMOS/methanol by coating 7 times was measured to be $2.28{\times}10^{-6}$, while that of PET film was $1.16{\times}10^{-4}$ GPU. The addition of fumed silica does not affect the oxygen barrier properties. It may be explained that silica particles disrupt chain packing, which leads to an increase in free volume for permeation.

  • PDF

XPS Studies of Oxygen Adsorption on Polycrystalline Nickel Surface

  • Lee, Soon-Bo;Boo, Jin-Hyo;Ahn, Woon-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.5
    • /
    • pp.358-362
    • /
    • 1987
  • The interaction of oxygen with polycrystalline nickel surface has been studied by investigating the X-ray photoelectron spectra of O 1s, Ni $2p_{3/2}$, and their valence band electrons. By comparing the oxygen exposure of this work with the reported results of LEED, AES, and work function measurements, it is found that the atomic oxygen, adsorbed dissociatively in the initial stage of exposure, is responsible for a p(2 ${\times}$ 2) structure and a subsequent c(2 ${\times}$ 2) structure on the Ni(100) surface. This dissociatively adsorbed oxygen species forms surface NiO layer subsequently on further oxygen exposure. The NiO layer is more easily formed with the increasing temperature. Non-stoichiometric oxygen species is also found to accompany the NiO layer. It appears prior to the formation of bulk NiO at all of the temperatures of this work except at 523K.

Development and Evaluation of a Teensy Microcontroller-based O2 Mass Flow Controller (Teensy 마이크로 컨트롤러 기반 산소 유량 제어기 개발 및 성능평가)

  • Yu, Min Sang;Jang, Yeonsook;Kim, Muhwan;Cho, Sungbo
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.193-200
    • /
    • 2021
  • Flowmeter and oxygen sensors are listed in COVID-19 essential medical devices. This article reports a Teensy microcontroller-based Oxygen mass flow controller (MFC), core part of the oxygen respirator or extracorporeal membrane oxygenation (ECMO). The developed MFC consisting of the microcontroller, MEMS flow sensor, and solenoid valve was able to accurately control 0 to 100 sccm of oxygen flow rate. The pressure of vacuum chamber increased proportionally to the flow rate (0.998 of Pearson correlation coefficient). The experimental results proved that the developed MFC exhibits comparable performance to a commercial MFC in accuracy, settling time, linearity with pressure, and repeatability of oxygen mass flow control. It is expected that this simple and cheap MFC is utilized for oxygen therapy against the severe acute respiratory syndrome coronavirus 2.

A Study of Aging of Oxygen Sensor (II) (산소센서의 열환에 관한 연구 (II))

  • 손건석;윤승원;고성혁;이귀영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Oxygen sensor taken from the aftertreatment systems of 4 vehicles which had been aged in domestic field examined for aging effects on emissions using a idel engine bench. also the artificial sensor signal generated by function generator was supplied to ECU, instead of oxygen sensor to simulate aging effects of oxygen sensor. This study shows that reduction of amplitude, deformation and shift of mean value of aged sensors seriously affect on the engine out emissions and the performance of TWC.

  • PDF

THE PROCESS OF THE DEVELOPMENT OF HYPOXIA IN AN ABNORMAL BLOOD FLOW II

  • Kwak, Min-Kyu;Go, Jae-Gwi
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.2
    • /
    • pp.59-66
    • /
    • 2007
  • The oxygen distribution at steady state is analyzed mathematically in a hexagonal cylinder. The domain is penetrated by parallel cylindrical capillaries of different oxygen squirt. Asymptotic solution is used to determine the effect of axial diffusion. Oxygen concentration profiles are displayed at some positions of capillary-beds. At the venous end some tissue areas suffer from a shortage of oxygen.

  • PDF