• 제목/요약/키워드: overload control

검색결과 252건 처리시간 0.023초

FDDI 네트워크의 파라미터 튜닝에 의한 과부하 제어 메카니즘 (Overload control mechanism by parameter tuning in FDDI networks)

  • 이준호;김경신;강문식;송명렬;이상배
    • 전자공학회논문지A
    • /
    • 제32A권4호
    • /
    • pp.32-39
    • /
    • 1995
  • In this paper, a timer thresholds tuning algorithm is proposed, satisfying the required response time for traffic with time-critical applications and asynchronous traffic in FDDI network. Under light and medium load, priorities and timer thresholds play a minor role for medium access control. In these cases all quenes are served exhaustively with a ver high service probability and the packet loss probability approaches almost zero. Under overload condition, however, the performance of the FDDI Network is completely determined by the selection of the timer thresholds. The timer thresholds tuned by mathematical results is confirmed by simulation results using SIMAN/UNIX package. The allocation of guaranteed bandwidth can be controlled easily by tuning the timer thresholds according to the proposed rules.

  • PDF

모선주입전력 조정에 의한 과부하 해소 앨고리즘 (Overload Alleviation Algorithm by the Bus Injection Power Control)

  • 박규홍;정재길;안민옥
    • 대한전기학회논문지
    • /
    • 제39권2호
    • /
    • pp.111-118
    • /
    • 1990
  • This paper presents a new algorithm of contingency analysis and countermeasure to alleviate the line overloads for electric power systems. In this algorithm, the inverse matrix of the new Jacobian matrix when a contingency occurs, in fastly calculated using the house-holder's Inverse Matrix Modification Lamma (IMML) with the original factor table. The generation outputs are firstly adjusted to alleviate all line overloads occurred by the contingency without tripping loads. If the generation adjustment is not enough anymore to alleviate line overloads, then the control of bus injection power is recommended to quickly alleviate remaining overloads with minimum amount of load tripping and generation read-justing at the termination busbars of the overload lines. The proposed algorithm has been validated in tests on the 6 busbar test system.

  • PDF

NetDraino: Saving Network Resources via Selective Packet Drops

  • Lee, Jin-Kuk;Shin, Kang-G.
    • Journal of Computing Science and Engineering
    • /
    • 제1권1호
    • /
    • pp.31-55
    • /
    • 2007
  • Contemporary end-servers and network-routers rely on traffic shaping to deal with server overload and network congestion. Although such traffic shaping provides a means to mitigate the effects of server overload and network congestion, the lack of cooperation between end-servers and network-routers results in waste of network resources. To remedy this problem, we design, implement, and evaluate NetDraino, a novel mechanism that extends the existing queue-management schemes at routers to exploit the link congestion information at downstream end-servers. Specifically, NetDraino distributes the servers' traffic-shaping rules to the congested routers. The routers can then selectively discard those packets-as early as possible-that overloaded downstream servers will eventually drop, thus saving network resources for forwarding in-transit packets destined for non-overloaded servers. The functionality necessary for servers to distribute these filtering rules to routers is implemented within the Linux iptables and iproute2 architectures. Both of our simulation and experimentation results show that NetDraino significantly improves the overall network throughput with minimal overhead.

Changes in Cytochrome c Oxidase and NO in Rat Lung Mitochondria Following Iron Overload

  • Kim, Min-Sun;Hong, Min-A;Song, Eun-Sook
    • Animal cells and systems
    • /
    • 제13권2호
    • /
    • pp.105-112
    • /
    • 2009
  • In this study, the effects of iron on cytochrome c oxidase (CcO) in rat lung mitochondria were examined. Similar to liver mitochondria, iron accumulated considerably in lung mitochondria (more than 2-fold). Likewise, the reactive oxygen species and nitric oxide (NO) content of mitochondria were increased by more than 50% and 100%, respectively. NO might be produced by nitric oxide synthase (NOS), eNOS and iNOS type, with particular contribution by NOS in mitochondria. The respiratory control ratio of iron overloaded lung mitochondria dropped to nearly 50% due to increased state 4. Likewise, cytochrome c oxidase activity was lowered significantly to approximately 50% due to excess iron. Real-time PCR revealed that the expression of isoforms 1 and 2 of subunit IV of CeO was enhanced greatly under excess iron conditions. Taken together, these results show that oxidative phosphorylation within lung mitochondria may be influenced by iron overload through changes in cytochrome c oxidase and NO.

Design and Implementation of the EEIS Considering the Load of DB Server

  • Kim, Chang-Geun;Park, Byeong-Jin;Tack, Han-Ho
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.37-43
    • /
    • 2003
  • Current Internet system of the entrance exam information to the university that is depending on searching key to solve the overloaded problem in the network and DB server or other tools to support HTML edit, haven't satisfied user's wants by supplying uniformed searching system. So this thesis will establish EEIS(Entrance Examination Information System) to prevent database overload phenomena when many users request a great amount of data at the same time and improve the decrease of speed and overload problem in DB server. EEIS playa role of bridge between outside client and DB server by placing VVS(Virtual View Server) between web server and DB server. By that method this system give users several usefulness in convenience and variety by supplying realtime data searching function to user. EEIS also give inner system manager more efficiency and speed in control the management system by solving those problem. This system is design and implementation to satisfy user's desire and give them more convenience and bring up the confidence of university that adopt this system at the end.

DB 서버 부하를 고려한 EEIS 시스템의 설계 및 구현 (Design and Implementation of the EEIS Considering the Load of DB Sewer)

  • 최병진;김창근;김봉기;김홍준
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.545-551
    • /
    • 2001
  • Current Internet system of the entrance exam information to the university that is depending on searching key to solve the overloaded p개blem in the network and DB server or other tools to support HTML edit, haven't satisfied user's wants by supplying uniformed searching system. So this thesis will establish EEIS(Entrance Examination Information System) to prevent database overload phenomena when many users request a great amount of data at the same time and improve the decrease of speed and overload problem in DB server. EEIS play a role of bridge between outside client and DB server by placing VVS(Virtual View Server) between web server and DB server. By that method this system give users several usefulness in convenience and variety by supplying realtime data searching function to user EEIS also give inner system manager more efficiency and speed in control the management system by solving those problem. This system is design and implementation to satisfy user's desire and give them more convenience and bring up the confidence of university that adopt this system at the end.

  • PDF

중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

반도체 스위칭 소자를 이용한 고속 고정밀의 전기화재 방재장치 (A Electrical Fire Disaster Prevention Device of High Speed and High Precision by using Semiconductor Switching Devices)

  • 곽동걸
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.423-430
    • /
    • 2009
  • 최근 저압 배전계통에서 사용되고 있는 과부하겸용 누전차단기 즉, RCD의 저조한 응답특성으로 인한 전기화재 원인의 대부분을 차지하는 단락사고 및 과부하사고에 대한 대응이 매우 미흡한 실정이다. 이에 본 논문에서는 기존 RCD에 대한 모의 사고실험을 통하여 그 비신뢰성을 확인하고, 이러한 RCD의 단점을 개선하고자 내구성과 속응성이 우수한 반도체 스위칭 소자들과 고정밀 전류센서를 이용한 "전기화재 방재장치(EFDPD : Electrical Fire Disaster Prevention Device)"를 제안하여 저압 배전계통에서의 단락 및 과부하사고로 인한 전기재해를 방지하고자 한다. 제안한 장치의 고정밀 전류센서로 사용된 리드스위치는 각종 전기사고에서 수반되는 단락전류 및 과전류에 의한 배전선로의 상승된 자속을 정밀 감지한 후, 자체 차단장치를 동작시키는 원리를 가진다. 다양한 동작특성 분석을 통하여 기존의 차단기와 비교하여 차단동작 응답속도와 그 신뢰성이 입증된다. 이로써 제안한 전기안전 제어장치는 기존 RCD들의 빈번한 오동작과 비신뢰성, 저조한 응답특성으로 인한 각종 전기사고 및 전기화재의 발생을 방지하고자 한다.