• Title/Summary/Keyword: overheating

Search Result 259, Processing Time 0.024 seconds

A Study on the Facility for Domestic Waste Problems of high Temperatured Combustion and the Alteration of heating surface (폐기물소각로의 고온 연소에 따른 문제와 연소실 전열면 변경에 대한 연구)

  • Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.3
    • /
    • pp.60-67
    • /
    • 2010
  • Korea's large-scale incinerating facilities of domestic waste were built in the late 1980's. It was found that most of the incinerators were designed during the period and even the ones constructed afterwards have been built without any changes or modifications. However, the nature of waste fed into incinerators is undergoing a radical change due to government policies on waste collection, which is upheld by a research into changes in the heating value of domestic wastes. As a result, refractories and stokers are being damaged in many of the facilities due to overheating. On the other hand, the formation of clinkers on boilers' heating surface, which curbs he at transfer, results in problems such as a fall in used heating value and a rise in the temperature of combustion chambers. Methods are being deployed to resolve the problems-such as spraying water on piles of waste, incinerating food waste by mixing together what has been separately collected, spraying water on combustion chambers, etc. Such actions are not a fundamental solution, nor redesigning and rebuilding incineration facilities is cost-effective. This research seeks to develop a fundamental solution to address the situation.

An Empirical Study on the Thermal Performance and Dynamic Behavior of Wall Integrated Thermosiphon Solar Water Heater (벽체일체형 자연순환 태양열온수기의 동적거동과 열성능에 관한 실증연구)

  • Baek, Nam-Choon;Kim, Sung-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.25-35
    • /
    • 2016
  • In this study, the evaluation of the dynamic behavior and thermal performance of the "Façade integrated Natural circulation Solar Water Heating System" installed in the residential house was carried out. Experimental tests were performed during the all year around in the rural houses of $166m^2$ in size. Facade integrated solar collector of $5m^2$ were installed on the south-facing. Electrical heater of 1 kW capacity as an auxiliary heater was installed at the upper part of the heat storage tank. The analyzing results are as follows. (1) Monthly average solar fraction was 51 to 87% and yearly average value is 64%. (2) Hot water supply temperature in December which has the lowest solar altitude is 37 to $76^{\circ}C$. The highest working fluid temperature of solar collector in this period was below $84^{\circ}C$. The temperature difference of working fluid between the collector inlet and outlet has been shown to be around 9 to $26^{\circ}C$. (3) Overheating which is one of the biggest problems during summer did not appear at all, but rather had hot water supply temperature is rather low as $30{\sim}47^{\circ}C$ in summer than winter, which is supplied by a small solar load. The solar collecting temperature has been shown to maintain below $55^{\circ}C$. (5) The thermal performance of Facade integrated solar collector can be increase due to the reduction of heat loss to the back of the collector wall integration of the collector is reduced. As a conclusion, Facade integrated natural circulation type Solar Water Heating System is a well-functioning without any pumps or controllers, and it was found that the disadvantages of conventional solar water heaters, hot water or hot water system can be greatly improved.

Short-term Construction Investment Forecasting Model in Korea (건설투자(建設投資)의 단기예측모형(短期豫測模型) 비교(比較))

  • Kim, Kwan-young;Lee, Chang-soo
    • KDI Journal of Economic Policy
    • /
    • v.14 no.1
    • /
    • pp.121-145
    • /
    • 1992
  • This paper examines characteristics of time series data related to the construction investment(stationarity and time series components such as secular trend, cyclical fluctuation, seasonal variation, and random change) and surveys predictibility, fitness, and explicability of independent variables of various models to build a short-term construction investment forecasting model suitable for current economic circumstances. Unit root test, autocorrelation coefficient and spectral density function analysis show that related time series data do not have unit roots, fluctuate cyclically, and are largely explicated by lagged variables. Moreover it is very important for the short-term construction investment forecasting to grasp time lag relation between construction investment series and leading indicators such as building construction permits and value of construction orders received. In chapter 3, we explicate 7 forecasting models; Univariate time series model (ARIMA and multiplicative linear trend model), multivariate time series model using leading indicators (1st order autoregressive model, vector autoregressive model and error correction model) and multivariate time series model using National Accounts data (simple reduced form model disconnected from simultaneous macroeconomic model and VAR model). These models are examined by 4 statistical tools that are average absolute error, root mean square error, adjusted coefficient of determination, and Durbin-Watson statistic. This analysis proves two facts. First, multivariate models are more suitable than univariate models in the point that forecasting error of multivariate models tend to decrease in contrast to the case of latter. Second, VAR model is superior than any other multivariate models; average absolute prediction error and root mean square error of VAR model are quitely low and adjusted coefficient of determination is higher. This conclusion is reasonable when we consider current construction investment has sustained overheating growth more than secular trend.

  • PDF

Heat Stress Assessment and the Establishment of a Forecast System to Provide Thermophysiological Indices for Harbor Workers in Summer (하계 항만열환경정보 제공을 위한 열환경 평가 및 예보시스템 구축)

  • Hwang, Mi-Kyoung;Yun, Jinah;Kim, Hyunsu;Kim, Young-Jun;Lim, Yeon-Ju;Lee, Young-Mi;Kim, Youngnam;Yoon, Euikyung;Kim, Yoo-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.92-101
    • /
    • 2016
  • Objectives: Outdoor workers are exposed to thermally stressful work environments. In this study, heat stress indices for harbor workers in summer were calculated to evaluate thermal comfort based on a human heat balance model. These indices are Physiological Subjective Temperature (PST), Dehydration Risk (DhR), and Overheating Risk (OhR) according to respective stage of cargo work in a harbor. In addition, we constructed a forecast system to provide heat stress information. Methods: Thermophysiological indices in this study were calculated using the MENEX model (i.e. the human heat balance model), which used as inputs the meteorological parameters, clothing insulation, and metabolic rate for each stage of cargo work in the harbor of Masan over the course of seven days, including a four-day heat wave. The forecast heat stress information constructed for Masan harbor was based on meteorological data supported by the Dong-Nae Forecast from the KMA (Korea Metrological Administration) and other input parameters. Results: According to higher metabolic rate, thermophysiological indices showed a critical level. In particular, PST was evaluated as reaching the 'Very hot' or 'Hot' level during all seven days, despite the heat occurring over only four. It is important in a regard to consider the work environment conditions (i.e. labor intensity and clothing in harbor). On a webpage, the forecast thermophysiological indices show as infographics to be easily understand. This webpage is comprised of indices for both current conditions and the forecast, with brief guidance. Conclusion: Thermophysiological indices show the risk level to health during a heat wave period. Heat stress information could help to protect the health of harbor workers. Further, this study could extend the applicability of these indices to a variety of outdoor workers in consideration of work environments.

A Study on The Ignition Limit of Flammable Gases by Discharge Spark of Resistive Circuit (저항회로의 개폐불꽃에 의한 폭발성 가스의 점화한계에 관한 연구)

  • Lee Chun-Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.106-112
    • /
    • 1997
  • This study measured the ignition limits of methane-air, propane-air, ethylene-air, and hydrogen-air mixture gases by discharge spark of D.C. power resistive circuit. The used experimental device is the IEC type spark ignition test apparatus, it consists of explosion chamber and supply -exhaust system of mixture gas. Mixture gases (methane-air, propane-air, ethylene-air, and hydrogen-air) were put into explosion chamber of IEC type spark ignition test apparatus, then it was confirmed whether ignition was made by 3,200 times of discharge spark between tungsten electrode and cadmium electrode. The ignition limits were found by increasing or decreasing the value of current. For the exact experiment, the ignition sensitivity was calibrated before and after the experiment in each condition. The ignition limits were found by changing the value of concentration of each gas-air mixture in D.C. 24 [V] resistive circuit. As the result of experiment, it was found that the minimum ignition limit currents exist at the value of methane-air 8.3 [$Vol\%$], propane-air 5.25[$Vol\%$], ethylene-air 7.8 [$Vol\%$], and hydrogen-air 21[$Vol\%$] mixture gases. For each the minimum ignition concentration of gases, the relationships between voltage and minimum ignition current were found. The results are as follows. - The minimum ignition limits are decreasing in the order of methane, propane, ethylene, and hydrogen. - The value of ignition current is inversely proportional to the value of source voltage. - The minimum ignition limit currents increase sharply at more than 2 [A]. The reason is caused by overheating the electrode.

  • PDF

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Analysis of Areas Vulnerable to Urban Heat Island Using Hotspot Analysis - A Case Study in Jeonju City, Jeollabuk-do - (핫스팟 분석을 이용한 도시열섬 취약지 특성 분석 - 전주시를 대상으로 -)

  • Ko, Young-Joo;Cho, Ki-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.67-79
    • /
    • 2020
  • Plans to mitigate overheating in urban areas requires the identification of the characteristics of the thermal environment of the city. The key information is the distribution of higher and lower temperatures (referred to as "hotspot" or "coldspot", respectively) in the city. This study aims to identify the areas within Jeonju City that are suffering from increasing land surface temperatures (LST) and the factors linked to such this phenomenon. To identify the hot and cold spots, Local Moran's I and Getis-Ord Gi* were calculated for the LST based on 2017 images taken using the thermal band of the Landsat 8 satellite. Hotspot analysis revealed that hotspot regions, (the areas with a high concentration of Land Surface Temperature) are located in the old town area and in industrial districts. To figure out the factors linked to the hotspots, a correlation analysis, and a regression analysis taking into account environmental covariates including Normalized Difference Vegetation Index (NDVI) and land cover. The values of NDVI showed that it had the strongest effect on the lowering LSTs. The results of this study are expected to provide directions for urban thermal environment designing and policy development to mitigate the urban heat island effect in the future.

Pasteurization Efficiency of a Continuous Microwave HTST (연속식 마이크로파 고온단시간 살균시스템에서 우유의 살균효과)

  • Kim, Suk-Shin;Lee, Joo-Hee;Kim, Sang-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1392-1396
    • /
    • 1999
  • This work was to apply the microwave energy to HTST pasteurization of milk in order to prevent undesirable quality changes due to the fouling and overheating on the surface of heat exchanger. A continuous tubulartype microwave pasteurization system was designed using a domestic microwave oven(800w and 2,450MHz). Raw milk was HTST pasteurized$(at\;72^{circ}C\;for\;15\;sec)$ by three methods; by heating in a stainless steel tube immersed in a hot water bath(MP0), by heating in a microwave cavity to a desired temperature and then holding in a hot water bath(MP1) and by both heating and holding in a microwave cavity(MP2). The microbial quality based on the total plate count and Psychotrophic bacterial count was in the order MP0, MP2 and MP1 ; however, the quality difference was not significant(p<0.05) when the initial microbial numbers were involved in the statistical analysis. In addition, the three samples pasteurized by different methods showed the similar microbial quality based on the coliform count and phosphatase activity. The similar microbial quality of the three samples supports the potential use of microwave energy for the pasteurization of milk and other fluid food products.

  • PDF

Developing an improved water discharge anchor & trap bolt to prevent basic salt penetration to harbor structures (해수 염기 침투방지를 위한 성능개선 형 물배출 앵커 및 트랩볼트 개발에 관한 연구)

  • Ock, Jong-Ho;Moon, Sang-Deok;Lee, Hwa-Sun;Shin, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.674-682
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Improving Haskell GC-Tuning Time Using Divide-and-Conquer (분할 정복법을 이용한 Haskell GC 조정 시간 개선)

  • An, Hyungjun;Kim, Hwamok;Liu, Xiao;Kim, Yeoneo;Byun, Sugwoo;Woo, Gyun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.9
    • /
    • pp.377-384
    • /
    • 2017
  • The performance improvement of a single core processor has reached its limit since the circuit density cannot be increased any longer due to overheating. Therefore, the multicore and manycore architectures have emerged as viable approaches and parallel programming becomes more important. Haskell, a purely functional language, is getting popular in this situation since it naturally supports parallel programming owing to its beneficial features including the implicit parallelism in evaluating expressions and the monadic tools supporting parallel constructs. However, the performance of Haskell parallel programs is strongly influenced by the performance of the run-time system including the garbage collector. Though a memory profiling tool namely GC-tune has been suggested, we need a more systematic way to use this tool. Since GC-tune finds the optimal memory size by executing the target program with all the different possible GC options, the GC-tuning time takes too long. This paper suggests a basic divide-and-conquer method to reduce the number of GC-tune executions by reducing the search area by one-quarter for every searching step. Applying this method to two parallel programs, a maximally independent set and a K-means programs, the memory tuning time is reduced by 7.78 times with accuracy 98% on average.