초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석 (Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line)

  • 임재섭;신구용;이동일;주문노;양광호
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

배전선로에서의 조가선 차폐 효과 연구 (A Study on a Shielding Effect of the Messenger Wires in Distribution Lines)

  • 김인수;한웅;여상민;김철환;원봉주;임용훈
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

송전선로 주변과 비주변 초등학생을 대상으로 극저주파 자기장 노출과 뇨중 멜라토닌 분비량간의 상관성 연구 (Relationship Between Urinary Melatonin Levels and Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Living Nearby and Away from Overhead Transmission Power Line)

  • 조용성;김윤신;이종태;홍승철;장성기
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.191-206
    • /
    • 2004
  • The present study investigated the hypothesis that a extremely low frequency magnetic field partially suppresses the synthesis of melatonin in a group of 28 primary schoolchildren living nearby and 60 primary schoolchildren aged 12 years living far away from overhead transmission power lines from December 2003 to April 2004 in Seoul, Korea. The mean personal exposure levels of the primary schoolchildren living nearby overhead transmission power line were 0.37 ${\mu}$T, whereas the value for the primary schoolchildren living away from overhead transmission power line 0.05 mT. From simple analyses, the mean melatonin levels in the primary schoolchildren living nearby were lower than away from overhead transmission power line, but not statistically significant differences in the levels of the melatonin (p=0.2421), whereas the statistically significant differences in the levels of the melatonin related to the distance from residence to power line less and more than 100 m by cut-off point (p=0.0139). In multiple linear regression analyses, distance from residence to power line (p=0.0146) and dietary habit about burned meat (p=0.0170) proved to be significant risk factors in the mean nocturnal melatonin levels in the primary schoolchildren. In conclusion, these results demonstrate that urinary levels of nocturnal melatonin are not altered in primary schoolchildren exposed to extremely low frequency magnetic field(ELF-MF) at overhead transmission power line.

와전류 기법을 이용한 가공전력선 열화 진단 (Degradation Diagnosis of Overhead Power Lines Using Eddy Current Technology)

  • 김충혁;김탁용;오용철;최운식;조춘남
    • 한국전기전자재료학회논문지
    • /
    • 제27권5호
    • /
    • pp.322-327
    • /
    • 2014
  • Internal corrosion of the distribution line can be detected in order to develop techniques of non-destructive inspection methods that operate only on the metal track eddy current diagnosis is possible by applying the technique investigated. Sensor for the production of a finite element method modeled by using an eddy current sensor, a distribution line by using an accelerated aging samples of sodium hydroxide was prepared. Sheathed cables for internal corrosion studies detected using an eddy current sensor is considered to be possible.

Applicability of Messenger Wire for Purpose of Lightning Protection

  • Seo, Hun Chul;Han, Joon;Choi, Sun Kyu;Lee, Byung Sung;Rhee, Sang Bong;Kim, Chul Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 2016
  • The Korean distribution line currently consists of overhead ground wires (OHGW), overhead distribution lines, neutral wires (NW), and messenger wires (MW). The MW is installed under the NW. The lightning protection system in Korea is focused on OHGW and lightning arrester and the MW are not considered. Therefore, this paper proposes the applicability of MW for purpose of lightning protection. For this, we analyzed the effects of lightning overvoltage according to the existence of OHGW and MW and the grounding conditions of the MW in the Korean distribution system. The grounding conditions of the MW that we took into consideration were the common or separate grounding of the MW and NW. The analysis based on the equivalent circuit of the distribution pole at each condition was performed. The distribution lines and lightning were modeled using the Electromagnetic Transients Program (EMTP). For each of the installation conditions of the OHGW and MW, the various lightning conditions were simulated and analyzed for both direct and indirect lightning. The simulation results showed that, if the OHGW was not installed in the Korean distribution system, the lightning overvoltage could be reduced by the common grounding of the MW and NW.

2도체 송전선로의 스페이서 취부방식 연구 (A Study on the Spacer Installation Method for 2-Conductor Bundle Transmission Lines)

  • 민병욱;김우겸;최한열;박기용;김원진;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.333-334
    • /
    • 2008
  • Overhead transmission lines are classified by the number of sub conductors per phase. Korean transmission lines use two, four, or six-conductor bundle. Bundle of conductors must have spacers or spacer dampers which keep the proper distance between sub conductors. They can prevent conductors from being vibrated or twisted due to the wind. As for the two-conductor bundle, alternating current flow generates absorption force between sub conductors which may cause a collision of sub conductors. To prevent sub conductors from being vibrated, twisted, and collided, spacer or spacer damper installation method is designed considering vibration characteristics of sub conductors. We have spacer installation method for four or six-conductor bundle lines. However, we don't have it for two-conductor bundle ones. So we have installed spacers at regular intervals in two-conductor bundle lines, and it caused rigid body oscillation of conductors due to the wind which made a flashover between conductors. This paper introduces a vibration characteristic analysis of two-conductor bundle and proposes a spacer installation method for two-conductor bundle lines.

  • PDF

전국의 송전선로 전자계 측정치와 계산치와의 비교 분석 (An analysis of the measured electric and magnetic fields of transmission lines in Korea)

  • 김상범;조성배;신구용;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2368-2370
    • /
    • 1999
  • A nationwide survey for electric and magnetic fields(EMFs) near overhead transmission lines has been conducted. The median values of the electric and magnetic fields of 208 transmission lines were 0.50 kV/m and 12.6 mG, respectively. The maximum values were 3.16 kV/m and 125 mG. The measured EMFs were compared with the calculated ones. The causes of the discrepancy between measured and calculated EMFs are also discussed.

  • PDF

345/154kV 초고압 송변전설비 주변에서의 전장의 측정과 분석 (Measurement and Analysis of Electric Field near 345/154kV UHV Overhead Transmission Lines and Substations)

  • 이정기;안창환;이복희;길경석;박동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1861-1863
    • /
    • 1996
  • In this paper, measurements and analyses of ELF electric fields in the vicinity of UHV overhead transmission lines and substations have been conducted. Planar-type sensors have been developed with special consideration of picking up lower frequency and spatial components without any distortion. So finally the electric field measuring system has the frequency bandwidth of 7[Hz] to 2.7[MHz] and the response sensitivity of 0.094[mV/V/m]. A brief description of design rules of the measuring system and measurement procedures is introduced. The actual survey near 154 and 345[kV] overhead transmission lines and power subststions was carried out and analyzed. It may be inferred from these results that the electric field intensity exeeds 7[kV/m] only in very few cases particularly at the substations so that the field measurements meet almost limits or guidelines that various authorized international institutes recommend.

  • PDF

전력선통신을 위한 고압 배전선로의 임피던스 특성 (Impedance Characteristics of Overhead Medium-Voltage Power lines for Power Line Communication)

  • 천동완;박영진;김관호;신철재
    • 대한전자공학회논문지TC
    • /
    • 제42권11호
    • /
    • pp.67-78
    • /
    • 2005
  • 본 논문에서는 전력선 통신(PLC) 시스템에 사용되는 고압 배전선로의 임피던스 특성을 해석하였다. 해석을 위해 전력선 통신 네트워크의 2포트 등가모델을 구현하였다. 등가모델 및 기본적인 전송선로 이론을 적용하여 전력선 통신 입력 단에서의 임피던스를 계산하였다. 또한 고압 커플러, 동축케이블 등의 특성을 제거한 전력선 자체의 입력임피던스를 계산하였다. 계산결과의 검증을 위해 고압 실증시험장에서 측정을 하였다. 측정결과 전력선 자체의 입력 임피던스는 $200\~300\;{\Omega}$의 값을 가졌으며, 주파수가 증가할수록 전력선 특성임피던스의 절반에 수렴하였다. 또한 측정치와 계산치가 매우 유사하였다.

카테너리 각도를 이용한 가공송전도체의 이도 추정 (Dip Estimation for Overhead Transmission Conductor using Catenary Angle)

  • 김성덕;손홍관;장태인
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.112-119
    • /
    • 2007
  • 가공송전 도체는 정상 동작조건 하에서 전력회사의 선로 설계지침에 규정된 지상고를 안정범위 내에서 항상 유지할 수 있어야 한다. 따라서 새로운 선로를 건설하거나 노화도체의 장력을 다시 조정하거나 또는 전력용량을 최대화하기 위해 동적송전용량을 모니터링하는 경우에, 도체 이도를 측정/또는 모니터링하는 것은 매우 중요하다. 본 연구에서는 도체의 카테너리 각도로 이도 및 장력을 추정하기 위한 새로운 방법을 제안한다. 가공송전선로의 대부분의 도체들은 전형적인 카테너리 곡선을 나타내므로 철탑 측의 카테너리 각도로부터 도체의 카테너리 곡선을 유일하게 결정할 수 있다. 이 카테너리 곡선을 토대로 도체의 이도나 수평장력을 쉽게 추정할 수 있다. 몇 가지 시뮬레이션과 간단한 실험 결과를 통하여 제안된 방법이 가공송전선의 도체 이도와 장력을 측정/또는 모니터링하는데 효과적으로 사용될 수 있음을 확인하였다.