• 제목/요약/키워드: overhead measurement

검색결과 123건 처리시간 0.025초

Control Flow Checking at Virtual Edges

  • Liu, LiPing;Ci, LinLin;Liu, Wei;Yang, Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권1호
    • /
    • pp.396-413
    • /
    • 2017
  • Dynamically checking the integrity of software at run-time is always a hot and difficult spot for trusted computing. Control-flow integrity is a basic and important safety property of software integrity. Many classic and emerging security attacks who introduce illegal control-flow to applications can cause unpredictable behaviors of computer-based systems. In this paper, we present a software-based approach to checking violation of control flow integrity at run-time. This paper proposes a high-performance and low-overhead software control flow checking solution, control flow checking at virtual edges (CFCVE). CFCVE assigns a unique signature to each basic block and then inserts a virtual vertex into each edge at compile time. This together with insertion of signature updating instructions and checking instructions into corresponding vertexes and virtual vertexes. Control flow faults can be detected by comparing the run-time signature with the saved one at compile time. Our experimental results show that CFCVE incurs only 10.61% performance overhead on average for several C benchmark programs and the average undetected error rate is only 9.29%. Compared with previous techniques, CFCVE has the characteristics of both high fault coverage and low memory and performance overhead.

가공 배전선의 열화를 검출하기 위한 솔레노이드 와전류 센서의 실험적 연구 (An Experimental Study on a Solenoid Eddy Current Sensor to inspect Deteriorations in Overhead Distribution Lines)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.77-85
    • /
    • 1999
  • 이 논문은 가공 배전선에서 단선, 극심한 국부부식이나 아연손실과 같은 열화상태를 검사하기 위하여 솔레노이드 와전류 센서를 이용한 비파괴검사 시스템의 실험적인 연구에 대하여 다룬다. ACSR과 ACSR-OC에 대한 부식기구가 검토되고 코일과 시료의 구조적인 파라미터들을 검사하기 위하여, 솔레노이드 센서의 임피던스도 간단히 해석된다. 정전류원, 신호처리 장치 및 모터 구동장치로 구성된 측정시스템이 제작되었다. 이 장비는 연속적으로 센서 출력을 검출하고 검사 도체의 결함을 추정하는 성능이 있다. 그 결과, 관통형 코일의 와전류 센서가 가공 배전선의 열화에 의한 직경 변화를 효과적으로 추정할 수 있음을 밝혔다.

  • PDF

전차선로 검측을 위한 실시간 화상처리 시스템 구현 (Implementation of Real-Time Monitoring System for Overhead Contact Wire in Electric Railway)

  • 박영;조용현;이기원;권삼영;박현준;장동욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.543-544
    • /
    • 2006
  • This paper describes a simple real-time monitoring system for use in measurement subsystem of contact wire and geometry of overhead contact wire in electric railway. The system has been consists of a high speed CMOS camera with resolution $1024\;{\times}\;1280$ pixels, line type laser source with a power equal to 300 mW, and PC-based image acquisition system with PCI Express slot. National instrument LabVIEW (8.0) and vision acquisition software have been used in application programming interface for image acquisition, display, and storage with a frequency of sampling of 500 acquisitions per second.

  • PDF

앱의 특성과 메모리 상황을 고려하는 스마트폰 스와핑 정책 (A Smartphone Swapping Policy that Considers the Characteristics of Applications and Memory Situations)

  • 반효경;김지선
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권3호
    • /
    • pp.13-18
    • /
    • 2023
  • 모바일 앱의 수가 지속적으로 증가함에 따라 스마트 폰 메모리 시스템에 스와핑 기능 탑재시 발생하는 오버헤드가 점점 증가하고 있다. 데스크탑이나 서버 시스템과 달리 스마트폰의 기본 세팅에서는 스와핑을 지원하지 않으며, 따라서 가용 메모리가 부족할 경우 앱들은 강제로 종료된다. 이는 스마트폰에 스와핑 기능 탑재시 지나친 스토리지 접근으로 인한 오버헤드가 발생하기 때문이다. 본 논문에서는 스토리지 접근량을 크게 줄이는 스마트폰용 스와핑 정책을 제안한다. 제안하는 정책에서는 모바일 앱을 그 기능적 특성에 따라 카테고리화하고 앱의 우선순위와 메모리 상황을 고려해서 스와핑 대상이 되는 앱의 수를 조절한다. 안드로이드 레퍼런스 디바이스를 활용한 실측 실험을 통해 제안하는 스와핑정책이 다양한 모바일 앱에 대해 스와핑의 오버헤드를 크게 줄일 수 있음을 확인하였다.

접지전류 측정에 의한 다중 접지계통의 접지저항 측정 (Measurement of Resistance of Multi-Grounded System by Ground Current Measurement)

  • 최종기;안용호;정길조;한병성;김경철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.234-237
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

접지전류 측정에 의한 다중 접지계통의 접지저항 측정 (Measurement of Resistance of Multi-Grounded System by Ground Current Measurement)

  • 최종기;안용호;정길조;한병성;김경철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.234-234
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

DTSTM: Dynamic Tree Style Trust Measurement Model for Cloud Computing

  • Zhou, Zhen-Ji;Wu, Li-Fa;Hong, Zheng;Xu, Ming-Fei;Pan, Fan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권1호
    • /
    • pp.305-325
    • /
    • 2014
  • In cloud computing infrastructure, current virtual machine trust measurement methods have many shortcomings in dynamism, security and concurrency. In this paper, we present a new method to measure the trust of virtual machine. Firstly, we propose "behavior trace" to describe the state of virtual machine. Behavior trace is a sequence of behaviors. The measurement of behavior trace is conducted on the basis of anticipated trusted behavior, which not only ensures security of the virtual machine during runtime stage but also reduces complexity of the trust measurement. Based on the behavior trace, we present a Dynamic Tree Style Trust Measurement Model (DTSTM). In this model, the measurement of system domain and user domain is separated, which enhances the extensibility, security and concurrency of the measurement. Finally, based on System Call Interceptor (SCI) and Virtual Machine Introspection (VMI) technology, we implement a DTSTM prototype system for virtual machine trust measurement. Experimental results demonstrate that the system can effectively verify the trust of virtual machine and requires a relatively low performance overhead.

산불에 의한 활선선로의 이도변화 거동 (Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire)

  • 김병걸;김상수;장용호;한세원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1295_1296
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperaures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

  • PDF

통전 중 산불에 노출된 가공송전선의 온도 및 장력 변화 거동 (Temperature and Load Change behavior of Overhead Conductor under loading current due to Forest Fire)

  • 김병걸;장용호;김상수;한세원
    • 한국전기전자재료학회논문지
    • /
    • 제22권4호
    • /
    • pp.366-371
    • /
    • 2009
  • The authors have published several technical reports on the deterioration of conductor due to forest fire in series so far. This is because even we have been experiencing hundreds of forest fires every year, no systematic research on conductor which is very vulnerable to fire have been fulfilled. This paper describes the sag-tension behavior of conductor under loading current normally when only partial area of a long conductor is exposed to fire. Temperatures of Overhead Conductor were different with measurement position. When the partial area of conductor was heated up to $500^{\circ}C$, 20 % of permanent tension loss was observed. This results in the increase of sag of 1.5 m when span is 300 m. The other results will be presented in the text.

Lifetime estimation of a covered overhead line conductor

  • Leskinen, Tapio;Kantola, Kari
    • Wind and Structures
    • /
    • 제6권4호
    • /
    • pp.307-324
    • /
    • 2003
  • The paper presents results of studies concerning wind-induced aeolian vibration and fatigue of a 110 kV covered conductor overhead line. Self-damping measurement techniques are discussed: power method is found to be the most reliable technique. A method for compensating tension variations during the self-damping test is presented. Generally used empirical self-damping power models are enhanced and the different models are compared with each other. The Energy Balance Analysis (EBR) is used to calculate the aeolian vibration amplitudes, which thereafter are converted to bending stress for the calculation of conductor lifetime estimate. The results of EBA are compared with field measurements, Results indicate that adequate lifetime estimates are produced by EBA as well as field measurements. Generally the EBA gives more conservative lifetime expectancy. This is believed to result from the additional damping existing in true suspension structures not taken into account by EBA. Finally, the correctness of the line design is verified using Cigre's safe design tension approach.