• 제목/요약/키워드: over thickness

검색결과 1,822건 처리시간 0.032초

유도가열 및 근적외선 가열방법에 의한 표면처리 강판 도포층의 가열 및 건조 특성 (Heating & Drying Characteristics of Coating Layer by Induction Heating and Short-wave Infrared Heating)

  • 김태수;양재원
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.249-257
    • /
    • 2004
  • Drying and curing characteristics of PCM resins using the induction heater and short-wave infrared emitter module was studied to develop a compact oven system for the high speed CCL and post-treatment equipment. Drying of the polyester resins using the induction heater and infrared heater showed that the blistering tendency of polyester resin coating increased regardless of additives and colors of resins as the heating rate and/or dry film thickness increased. The blistering of polyester resin coating layer occurred when the heating speed was over than $25^{\circ}C/sec$ for the dry film thickness of $19\~20um$, which is the typical thickness of finish coating in CCL. So did it when the heating speed was over than $40^{\circ}C/sec$ for the dry film thickness over than 10 um. The heating efficiency of paint coated steels by the infrared heating was strongly dependent on the colors of paint coating and generally increased for the dark surface and/or coating. But the faster drying of the PCM resin coatings increased the blistering tendency of coating layer. The blistering limit for the typical finish coating by the infrared heating was estimated as the heating rate slower than $20^{\circ}C/sec$ regardless of colors of PCM resins.

  • PDF

전구 해빙모델(CICE)을 이용한 해빙 농도와 해빙 두께 민감도 비교 (Sensitivity Study of Simulated Sea-Ice Concentration and Thickness Using a Global Sea-Ice Model (CICE))

  • 이수봉;안중배
    • 대기
    • /
    • 제24권4호
    • /
    • pp.555-563
    • /
    • 2014
  • The impacts of dynamic and thermodynamic schemes used in the Community Ice CodE (CICE), the Los Alamos sea ice model, on sea ice concentration, extent and thickness over the Arctic and Antarctic regions are evaluated. Using the six dynamic and thermodynamic schemes such as sea ice strength scheme, conductivity scheme, albedo type, advection scheme, shortwave radiation method, and sea ice thickness distribution approximation, the sensitivity experiments are conducted. It is compared with a control experiment, which is based on the fixed atmospheric and oceanic forcing. For sea ice concentration and extent, it is found that there are remarkable differences between each sensitivity experiment and the control run over the Arctic and Antarctic especially in summer. In contrast, there are little seasonal variations between the experiments for sea ice thickness. In summer, the change of the albedo type has the biggest influence on the Arctic sea ice concentration, and the Antarctic sea ice concentration has a greater sensitivity to not only the albedo type but also advection scheme. The Arctic sea ice thickness is significantly affected by the albedo type and shortwave radiation method, while the Antarctic sea ice thickness is more sensitive to sea ice strength scheme and advection scheme.

Effects of Different Sizes of Blood Flow Restriction Areas on Changes in Muscle Thickness

  • Park, Jae-Cheol;Park, Mi-Sook;Kim, Yong-Nam
    • The Journal of Korean Physical Therapy
    • /
    • 제29권2호
    • /
    • pp.80-84
    • /
    • 2017
  • Purpose: This study was conducted to examine the effects of different sizes of blood flow restriction areas on the thickness of the external oblique and biceps brachii. Methods: The study subjects were 52 adults who were divided into four groups that performed plank exercises over a six-week period after blood flow restriction. Changes in the thickness of the external oblique and biceps brachii were measured using ultrasonography before the experiment, then three and six weeks after the experiment. The changes in each variable over time were evaluated by repeated-measures analysis of variance (ANOVA). Results: The external oblique and biceps brachii showed significant differences in muscle thickness with regard to time and the interaction between time and each group (p<0.01), but no significant differences with regards to changes between groups (p>0.05). Conclusion: A larger blood flow restriction area resulted in a statistically significant increase in muscle thickness. The results of this study may be used as the basis for future studies and for rehabilitation in clinical practice.

하지 석고붕대제거후 정상측과 석고붕대 적용측의 상하지의 둘레, 피부두겹두께 및 하지근력의 비교 (Comparison of the circumference, skinfold thickness and leg strength of normal limb with those of casted limb following removal of leg cast)

  • 최명애;박미정
    • 대한간호학회지
    • /
    • 제23권1호
    • /
    • pp.56-67
    • /
    • 1993
  • The purpose of this study was to compare the circumference and skinfold thickness of upper and lower limb and the leg strength of the casted limb with those of the normal limb after removal of a leg cast. The subjects for the study were orthopedic patients who had had long and short leg casts or splints due to tibial, fibulal, metatarsal, calcaneus fracture or ankle sprains. The subjects were divided into two groups, those who had the cast on for less than 40 days and those for over 41 days. Circumference and skinfold thickness of the upper and lower limb on the side on which the cast was ap-plied were compared with those of the contralateral side after removal of the cast. Circumference and skinfold thickness of the upper and lower limb, and leg strength for those in a cast for under 40 days were compared with those of over 41 days for both the side to which cast was applied and the contralateral side. Measurements were made after removal of the cast. Skinfold thickness was measured by fat caliper, circumference was measured by tape and lower extremity strength was determined with flat foot pressing on an electronic digital health meter in the sitting position. The results can be summarized as follows : 1. The circumference of the upper and lower leg on the side on which the cast was applied, when measured after the cast was removed, were significantly less than those of the normal side, 93.88%, 93.11% each. 2. Skinfold thickness of the quadriceps and gastrocnemius on the side on which the cast was applied were significantly less than those of the normal side when measured after removal of the cast, 85.98%, 82.85% respectively. 3. Leg strength on the side where the cast was applied was significantly 1ss than that on the normal side, 60.20%. 4. There was no difference in the circumference of upper and lower limbs, skinfold thickness or leg strength on the side where the cast was applied between the group which had the cast applied for under 40 days and the group that had it applied for over 41 days. 5. The circumference of the upper arm and lower leg on the normal side for the group that had the cast applied for over 41 days was significantly greater than the group that had the cast application for under 40 days. T ere was no difference between the two groups in the circumference of the forearm and upper leg, skinfold thickness and leg strength in the normal side. From these results, it may be concluded that muscle atrophy was apparent in the casted limb compared to the normal limb, and the circumference of the upper arm and lower leg, and leg strength on the normal side increased after removal of the cast in the group which had the cast on for more than 41 days.

  • PDF

Effect of initial placement level and wall thickness on maintenance of the marginal bone level in implants with a conical implant-abutment interface: a 5-year retrospective study

  • Yoo, Jaehyun;Moon, Ik-Sang;Yun, Jeong-Ho;Chung, Chooryung;Huh, Jong-Ki;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제49권3호
    • /
    • pp.185-192
    • /
    • 2019
  • Purpose: Implant wall thickness and the height of the implant-abutment interface are known as factors that affect the distribution of stress on the marginal bone around the implant. The goal of this study was to evaluate the long-term effects of supracrestal implant placement and implant wall thickness on maintenance of the marginal bone level. Methods: In this retrospective study, 101 patients with a single implant were divided into the following 4 groups according to the thickness of the implant wall and the initial implant placement level immediately after surgery: 0.75 mm wall thickness, epicrestal position; 0.95 mm wall thickness, epicrestal position; 0.75 mm wall thickness, supracrestal position; 0.95 mm wall thickness, supracrestal position. The marginal bone level change was assessed 1 day after implant placement, immediately after functional loading, and 1 to 5 years after prosthesis delivery. To compare the marginal bone level change, repeated-measures analysis of variance was used to evaluate the statistical significance of differences within groups and between groups over time. Pearson correlation coefficients were also calculated to analyze the correlation between implant placement level and bone loss. Results: Statistically significant differences in bone loss among the 4 groups (P<0.01) and within each group over time (P<0.01) were observed. There was no significant difference between the groups with a wall thickness of 0.75 mm and 0.95 mm. In a multiple comparison, the groups with a supracrestal placement level showed greater bone loss than the epicrestal placement groups. In addition, a significant correlation between implant placement level and marginal bone loss was observed. Conclusions: The degree of bone resorption was significantly higher for implants with a supracrestal placement compared to those with an epicrestal placement.

Current Concept of Management of Partial-thickness Rotator Cuff Tear

  • Lim, Tae Kang;Park, Jae Hyun
    • Clinics in Shoulder and Elbow
    • /
    • 제17권4호
    • /
    • pp.209-217
    • /
    • 2014
  • Most studies on the pathophysiology, natural history, diagnosis by imaging and outcomes after operative or nonoperative treatment of rotator cuff tear have focused on those of full-thickness tears, resulting in limited knowledge of partial-thickness rotator cuff tears. However, a partial-thickness tear of the rotator cuff is a common disorder and can be the cause of persistent pain and dysfunction of the shoulder joint in the affected patients. Recent updates in the literatures shows that the partial-thickness tears are not merely mild form of full-thickness tears. Over the last decades, an improved knowledge of pathophysiology and surgical techniques of partial-thickness tears has led to more understanding of the significance of this tear and better outcomes. In this review, we discuss the current concept of management for partial-thickness tears in terms of the pathogenesis, natural history, nonoperative treatment, and surgical outcomes associated with the commonly used repair techniques.

샌드위치 평판의 모드 감쇠 최대화를 위한 점탄성층 두께 결정법 (A Method to Determine Optimum Viscoelastic Layer Thickness of Sandwich Plate for Maximum Modal Damping)

  • 남대호;신윤호;김광준
    • 한국소음진동공학회논문집
    • /
    • 제16권7호
    • /
    • pp.690-696
    • /
    • 2006
  • Thickness of damping layer in sandwich plate needs to be optimized in order to make modal loss factor of the sandwich plate maximum. Since previous studies were interested in noise reductions over high frequency range, the modal properties were derived based on simply supported boundaries. This conventional formula is approximately applicable to other boundary conditions over high frequency range only. The purpose of this study is to propose a method to determine optimum damping layer thickness of sandwich plate for maximum modal damping in low frequency range when the boundary condition is not a simple support. The conventional RKU equation based on simply supported boundary is modified to reflect other boundary conditions and the modified RKU equation is subsequently applied to determine the optimum damping layer thickness for arbitrary conditions. In order to reflect frequency-dependent characteristics of elastic modulus of the damping layer, an iteration method is proposed in determining the modal properties. Test results on sandwich plates for optimum damping layer thickness are compared with predictions by the proposed method and conventional method.

파노라마방사선사진을 이용한 연령별 하악 피질골 두께에 관한 연구 (The relationship between age and the mandibular cortical bone thickness by using panoramic radiograph)

  • 김윤숙;김경아;고광준
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.83-87
    • /
    • 2010
  • Purpose : This study was to determine the relationship between age and the mandibular cortical bone thickness on panoramic radiograph. Materials and Methods : Panoramic radiographs of 360 patients (180 men and 180 women) over 20 years old, who visited the Chonbuk National University Hospital from January to December in 2007, were assessed. The subjects were divided into 5 age groups. Five indices such as cortical bone thickness at the gonion (GI), antegonion (AI), and below the mental foramen (MI), the panoramic mandibular index (PMI), the mandibular cortical index (MCI) were measured on panoramic radiographs. Results : All five indices including GI, AI, MI, PMI, and MCI showed significant differences between third decade and over 8 decade groups (p<0.05). PMI, MI and GI showed significant differences with gender statistically (p<0.05). Conclusion : The mandibular cortical bone thickness showed negative correlation with age, and the value of the thickness (PMI, MI, and GI) was greater in men than in women.

Tungsten polycide gate 구조에서 $WSi_x$ 두께와 fluorine 농도가 gate oxide 특성에 미치는 영향 (Effects of $WSi_x$, thickness and F concentration on gate oxide characteristics in tungsten polycide gate structure)

  • 김종철
    • 한국진공학회지
    • /
    • 제5권4호
    • /
    • pp.327-332
    • /
    • 1996
  • Tungsten(W) polycide gate 구조에서 $WSi_x$의 두께가 증가하면 열처리 공정 후 Gate oxide의 두께가 증가하며, 전기적 신뢰도가 열화 되는 현상이 발생한다. 이러한 특성 열화를 일으키는 지배적인 요인은 $WSi_x$ 증착 공정 중 유입되어 후속 열 공정에 의하여 gate oxide로 환산되는 fluorine인 것으로 밝혀졌다. 이러한 현상을 규명하기 위하여 fluorine ion implantation된 poly Si과의 특성을 비교하였으며, SIMS 및 단면 TEM을 이용한 미세 구조 연구를 실시하였다. 그러나 $WSi_x$의 두께가 600$\AA$ 이상부터는이러한 특성 열화가 포화되는 현상이 관찰되었다. 600$\AA$ 이상의 $WSi_x$ 두께에서는 미세 구조가 표면이 거칠고, porous한 phase로 구성된 상부 구조와 비교적 dense하고, 매끈한 계면 상태를 갖는 하부 구조로 이루어졌으며, porous한 표면 부위는 후속 열공정 중 oxygen-rich한 phase로 변하여 fluorine을 포획하여 oxide로의 확산을 억제하여 특성 열화가 포화되는 것으로 해석되었다.

  • PDF

The Reliability of Thickness Measurement of the Deep Fiber of the Lumbar Multifidus Using Ultrasonography

  • Jung, Doh-Heon;Kim, Su-Jung;Yi, Chung-Hwi;Cynn, Heon-Seock;Choi, Houng-Sik
    • 한국전문물리치료학회지
    • /
    • 제17권4호
    • /
    • pp.49-54
    • /
    • 2010
  • The reliability of the thickness measurement of the lumbar multifidus (LMD using real-time ultrasonography (US) was determined in only the superficial fiber of the lumbar multifidus (SM). However, previous studies have not examined the reliability of the deep fiber of the LM (DM). The purpose of this study was to determine the intrarater and the interrater reliability of the thickness measurements of DM using US. Eleven heathy males participated in the study. The thickness of the DM was measured with an US in the prone position. Reliability was examined using intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland and Altman plot. ICC(3,1) was used to calculate the interrater reliability of the thickness measurement of DM using the values from both the first and second test sessions. Additionally, ICC(3,1) was used to calculate the intrarater reliability of the measurements over two days using the measurements obtained in test session 1 and lest session 2. The results of this study were as follows: 1) the ICC(3,1) value for interrater reliability was .94 in the first test session, and .93 in the second test session. 2) the ICC(3,1) values for intrarater reliability of the measurements over two days was .90 in both the first examiner and the second examiner. The interrater reliability and interrater reliability of the DM measurements, obtained via the US protocol used in this research was excellent. Therefore, we conclude that the thickness measurement of the DM obtaioned from the US protocol used in this research would be useful for clinician assessment of the thickness of the DM.