• 제목/요약/키워드: outdoor temperature

검색결과 797건 처리시간 0.022초

냉·난방도일에 따른 건물에너지 사용량 보정기법 개발 (The Development of the Calibration Method of Building Energy Consumption by HDDm and CDDm)

  • 김동일;이병호
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.15-26
    • /
    • 2018
  • It is difficult to check the exact building energy consumption reduction such as when green remodeling of buildings, because it is due to outdoor air temperature over the years. And in Korea although Big Data of building energy consumption is collected and managed through "The Information System of the Building Energy and Greenhouse Gases" it is underutilized because of non calibration of outdoor air temperature change. Therefore, this study aims to develope calibration method of building energy consumption by outdoor air temperature according to micro climates, and building use types. As a result of analysis, Regression equations of Building energy consumption and $HDD_m/CDD_m$ are derived and calibration method is developed by Regression coefficient.

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

혹한기 결빙 방지를 위한 열회수형 환기장치 개발에 관한 연구 (A Study on the Development of Heat-Recovery Ventilator for Preventing Freezing in a Cold Weather)

  • 박우철;김일겸;태경응
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.593-598
    • /
    • 2018
  • 본 연구는 혹한기 결빙 방지를 위한 열회수형 환기장치의 개발에 관한 연구로써, 개발에 필요한 내부 리턴 댐퍼를 최적화하여 적용하기 위하여 전산유체해석(Computational Fluid Dynamics)을 수행하였고 이를 바탕으로 실험을 위한 시제품을 만들어 혹한기 결로 및 결빙실험을 수행하였다. 배기 재순환 비율이 최대가 되는 최적의 내부 리턴 댐퍼를 설계하기 위하여 총 16 model의 전산유체해석을 수행하였다. 전산유체해석 결과 외기에 대한 배기 재순환 비율은 59.9% ~ 62.3%로 나타났다. 외기온도(Outdoor Air Temperature)가 $-15^{\circ}C$ 이상에서는 배기 재순환 운전과 통상 운전 모두 결로와 결빙이 발생하지 않았다. 그러나 외기온도가 $-20^{\circ}C$에서는 내부 리턴 댐퍼를 $45^{\circ}$ 열어 배기 재순환 운전을 하여야 결로와 결빙이 발생하지 않았다. 혹한기 결빙 방지를 위한 열회수형 환기장치는 외기온도에 따라 통상 운전 모드와 배기 재순환 운전 모드의 두 가지 운전모드로 운전하여야 한다. 외기온도가 $-15^{\circ}C$보다 높을 경우에는 통상 운전 모드로 작동하고 외기온도가 $-15^{\circ}C$보다 낮을 경우에는 재순환 운전 모드로 작동하는 열회수형 환기장치의 운전 알고리즘을 개발하여 적용하였다.

하절기 효율적인 하우스 온도 습도 관리에 관한 연구 (Studies on Management of Effective Temperature and Humidity in Greenhouse at Summer Season)

  • 우영회;남윤일;송천호;김형준;김동억
    • 생물환경조절학회지
    • /
    • 제3권1호
    • /
    • pp.58-65
    • /
    • 1994
  • 본 시험은 하절기 경제성을 고려한 효율적인 온도하강방법을 구명하고자 차광재료, fog system, 송풍등 복합적 온도하강처리에 따른 비닐하우스의 기상환경변화를 조사하여 다음과 같은 결과를 얻었다. 1. 중형하우스에서 온도하강방법에 따른 환경특성은 처리에 따라 하우스의 고온화를 상당히 효율적으로 억제하였다. 7월31일 하우스냉방처리에 따른 기온의 일중변화를 경시적으로 보면 수분의 증발잠력능력을 이용한 fog system과 은색차광 및 송풍을 혼합하여 처리할 경우 기온과 지온은 외기온에 비하여 최고 각각 1$0^{\circ}C$, 4$^{\circ}C$정도 온도하강효과가 있었으며 그 다음은 은색차광+fog system, 은색차광+송풍, 흑색차광+송풍구 순이였다. 2. 하절기 가장 온도가 높은 시기인 7월20일부터 8월21일까지 하우스냉방처리에 따른 온도하강 효과를 보면 최고기온은 시험처리에 따라 온도차가 인정되며 은색차광+fog system+송풍구의 지상, 지표면기온은 외기온에 비하여 각각 약 8$^{\circ}C$, 7$^{\circ}C$정도 온도하강 효과가 있었다. 3. 은색차광+송풍구와 흑색차광+송풍구의 일사량은 청명한날 외기일사량에 비하여 각각 약 29.3%, 32.5%이였으며 흐린 날은 각각 약 27.4%, 31.8%이였다.

  • PDF

가정용 에어컨 실외기의 기동 소음 분석 (The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner)

  • 손영부;이승목;하종훈;이병철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

공단지역과 시골지역 주택 실내, 실외 및 개인의 이산화질소 노출평가 (Indoor, Outdoor, and Personal Exposure to Nitrogen Dioxide Comparing Industrial Complex Area with Country Area)

  • 양원호;임성국;손부선
    • 한국환경보건학회지
    • /
    • 제34권3호
    • /
    • pp.183-187
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay, and outdoor levels. Various indoor and out-door combustion sources produce nitrogen dioxide ($NO_2$), which is a by-product of high temperature fossil fuel combustion. Especially, the presence of gas ranges and smoking have been identified as major factors contributing to indoor $NO_2$ exposures. In this study, we compared an industrial complex area with a country area by assessing the personal exposure to $NO_2$with measurements of indoor and outdoor $NO_2$ levels in residences and by house characteristics and questionnaire. Personal exposure concentrations were significantly correlated with indoor $NO_2$ concentrations of residences in both the industrial complex area and the country area with correlation coefficients of 0.561 and 0.664, respectively, compared to outdoors. Multiple regression analysis, indicated that indoor $NO_2$ levels in residences were only affected by outdoor levels (p = 0.000) in spite of higher indoor sources such as smoking. Therefore, it is suggested that outdoor air quality as well as indoor air quality should be considered in the reduction of the personal exposure to air pollutants.

여름철 도시의 일상생활에서 폭로되는 환경온도와 온냉감 평가 (Thermal Diary - 24 hours' Exposed Temperature and Thermal Comfort in Urban Life, Summer)

  • 이민정;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.333-337
    • /
    • 2002
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces and experiences temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects are the college students wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Most subjects get weather information(84.6%). Fashion(46.2%) and weather (30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Exposed temperature fluctuation were from 33.8$^{\circ}C$ to 15.6$^{\circ}C$. The median value of experienced temperature were 26-27$^{\circ}C$ and average temperature was 26.3$^{\circ}C$. Subjects experienced cold shock of 3.96 times in a day and 67.21% of all evaluated thermal comfort in the range of -1 and 1 by ASHRAE 7 Category Scales. Artificial environment which connected with outside let people experienced temperature fluctuation in wide range.

  • PDF

서울시 일부 지역의 대기 중 부유 진균의 분포 특성 (Distribution Characteristics of Airborne Fungi in a Partial Area of Seoul City)

  • 김기연;김대근
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.407-414
    • /
    • 2012
  • Objectives: This study was performed to assess based on field investigation the distribution characteristics of airborne fungi in an area of Seongdong-gu, Seoul. Methods: Three sites, a living area, forest and traffic site, were selected for evaluation of monthly level of outdoor airborne fungi. An on-site survey was executed between January 2009 and December 2009. During the experimental period, air sampling was performed every month in the afternoon (2:00 pm-5:00 pm) using a cascade impactor. Results: Outdoor airborne fungi measured in Seoul, Korea over one year showed a concentration range from 850CFU $m^{-3}$ to 15,200CFU $m^{-3}$. The mean respirable fraction of outdoor airborne fungi was 67% compared to total concentration. Regardless of measurement site, there was no significant concentration difference in outdoor airborne fungi between periods of yellow dust and non-yellow dust (p>0.05). There was no significant correlation relationship between outdoor airborne fungi and atmospheric factors such as temperature and relative humidity. The predominant genera of airborne fungi identified were Aspergillus, Cladosporium, Paecilomyces and Penicillium. Conclusion: Monthly levels of outdoor airborne fungi were highest in April and November and lowest in August. In seasonal concentration distribution, the autumn showed the highest level of outdoor airborne fungi, followed by spring, summer and winter. In regional concentration distribution, the highest level of outdoor airborne fungi was generally found in the forest, followed by the living area and traffic site.

기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석 (Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor)

  • 이원영;심규일;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF

The Production of Algal Hydrocarbons in Outdoor Cultivations of Dunaliella salina 1650

  • Pak, Jin-Hong;Lee, Shin-Young;Kim, Young-Nam
    • Journal of Microbiology and Biotechnology
    • /
    • 제3권1호
    • /
    • pp.46-50
    • /
    • 1993
  • In 12:12 hour light/dark cycle cultivation of D. salina 1650, maximum specific growth rate of 0.59 (l/day) and 0.35 (g-crude hydrocarbons/l/day) were obtained. The cell growth was inhibited at above 15$\times$$10^{-4} (kcal/cm^2/h)$ of light intensity in an outdoor cultivation. It was also showed that temperature is one of the critical growth parameters in the outdoor cultivation. The hydrocarbon production from D. salina 1650 seems to be partially growth related production process, and these algal hydrocarbons can be used for subsituting petroleum directly or through cracking processes. The value of weight fraction carbon of D. salina 1650 was similar to that of Botryococcus braunii and so was the hydrocarbon productivity.

  • PDF