• 제목/요약/키워드: outdoor experiment

검색결과 275건 처리시간 0.029초

Analysis of Outdoor Positioning Results using Deep Learning Based LTE CSI-RS Data

  • Jeon, Juil;Ji, Myungin;Cho, Youngsu
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권3호
    • /
    • pp.169-173
    • /
    • 2020
  • Location-based services are used as core services in various fields. In particular, in the field of public services such as emergency rescue, accurate location estimation technology is very important. Recently, the technology of tracking the location of self-isolation subjects for COVID-19 has become a major issue. Therefore, location estimation technology using personal smart devices is being studied in various ways, and the most widely used method is to use GPS. Other representative methods are using Wi-Fi, Pedestrian Dead Reckoning (PDR), Bluetooth Low Energy (BLE) beacons, and LTE signals. In this paper, we introduced a positioning technology using deep learning based on LTE Channel State Information-Reference Signal (CSI-RS) data, and confirmed the possibility through an outdoor location estimation experiment using a commercial LTE signal.

실내외 천이영역 적용을 위한 WLAN/GPS 복합 측위 알고리즘 (A WLAN/GPS Hybrid Localization Algorithm for Indoor/Outdoor Transit Area)

  • 이영준;김희성;이형근
    • 제어로봇시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.610-618
    • /
    • 2011
  • For improved localization around the indoor/outdoor transit area of buildings, this paper proposes an efficient algorithm combining the measurements from the WLAN (Wireless Local Area Network) and the GPS (Global Positioning System) for. The proposed hybrid localization algorithm considers both multipath errors and NLOS (Non-Line-of-Sight) errors, which occur in most wireless localization systems. To detect and isolate multipath errors occurring in GPS measurements, the propose algorithm utilizes conventional multipath test statistics. To convert WLAN signal strength measurements to range estimates in the presence of NLOS errors, a simple and effective calibration algorithm is designed to compute conversion parameters. By selecting and combining the reliable GPS and WLAN measurements, the proposed hybrid localization algorithm provides more accurate location estimates. An experiment result demonstrates the performance of the proposed algorithm.

김치냉장고를 중심으로한 소형 멀티 냉동시스템의 성능특성 변화에 관한 연구 (Evaluation on the Cyclic and Adiabatic Performance of a Small Multi-Refrigeration system)

  • 이무연;최석재;김상욱;이원근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.769-774
    • /
    • 2003
  • In this paper, the performance of a domestic Kim-Chi refrigerator is predicted by using a calculation model & experiment. The objectives of this study are to find out the best design points of a refrigeration system and calculate an adiabatic characteristic to change outdoor temperature. The best design points such as refrigerant charge and capillary length were experimentally investigated. And the calculation model is conducted as a function of calculation parameters and outdoor temperature. According to this study results, the best design points of a refrigeration system are each 95g of a refrigerant charge and 3500/3500mm of capillary lengths. And the power consumption is 13.578 Kwh/month. And a part of the worst heat loss is a front side of a domestic Kim-Chi refrigerator body.

  • PDF

에어컨 실외기용 축류홴의 성능에 관한 연구: 소음 특성 (Analysis on Performance of Axial Flow Fan for Outdoor Unit of Air-conditioner: Noise Characteristics)

  • 김용환;이장호
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.29-34
    • /
    • 2010
  • In this paper, aerodynamic noise of axial flow fans for outdoor unit of air-conditioner was analyzed by both experiment and numerical simulation. The three-dimensional incompressible turbulent flow was predicted by the commercial computational fluid dynamics code SC/Tetra, while the aeroacoustic noise of an axial flow fan was predicted by FlowNoise. Computations and experiments were performed with two types of axial flow fans, in which very different noise source distributions were presented. The results obtained from this study are expected to show the way to reduce the noise of axial flow fans in industrial applications.

공동주택의 태양열 집열기 효율에 대한 실험적 연구 (An Experimental Study on the Solar Collector Efficiency for Apartment Building)

  • 최병도;김미연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

바닥난방시스템의 외기온도 변화특성을 고려한 운전방안에 관한 연구 (A Study on the Operational Strategies for Outdoor Air Temperature Change Characteristics in a Radiant Floor Heating System)

  • 안병천;송재엽
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.685-692
    • /
    • 2013
  • In this study, the control characteristics and effects of heating control methods on the heating performance and energy consumption of a hot-water heating control system of a residential apartment were researched by simulation and experiment. The purpose of this study is to evaluate operational strategies for improving an indoor thermal environment and reducing f energy consumption in the radiant floor heating system of a residential apartment.

자외선 노출에 따른 폴리머애자 하우징의 열화특성평가 (Aging Evaluation of Polymer Insulator Housing with UV Exposure)

  • 이병성;한재홍;김찬영;한용희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.214-217
    • /
    • 1999
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in a outdoor environment is still very limited. Especially, these insulator are subjected to the environmental stress such as ultraviolet radiation. Hence, in this paper. the influence of UV radiation on the aging of the shed materials was evaluated. For the aging evaluation, these insulators studied by experiment methods such as contact angle measurement. oxidation induced time. SEM/EDX, FTRI-ATR, tracking test for the different insulator samples. With the increased UV exposure time, samples are shown to exhibit degradation comparable to those of new ones

  • PDF

랜덤하프변환과 코너추출을 이용한 경사면의 장애물 위치 탐색 (Obstacle Position Detection on an Inclined Plane Using Randomized Hough Transform and Corner Detection)

  • 황선민;이민철
    • 제어로봇시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.419-428
    • /
    • 2011
  • This paper suggests a judgement method for an inclined plane before entrance of it and the detection of obstacle position. Main idea is started from the assumption that obstacle is always on the bottom plane, and corner appears at this position. The process to detect the obstacle consists of three steps. First the 3D data using stereo matching is acquired to detect an obstacle. Second a bottom plane is extracted by using limit condition. Last the obstacle position is found by using Harris corner detection. Obstacle position detection on an inclined plane was verified by outdoor and indoor experiment. In error analysis, it is confirmed that an average error of obstacle detection in outdoor was larger than the error in indoor but the error are within about 0.030 m. This method will be applied to unmanned vehicles to navigate under various environment.

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.

전열교환 환기시스템의 외기변화에 따른 성능평가 및 에너지평가를 통한 운전방안에 관한 연구 (A Study on Operating Method by Energy Evaluation and Performance Evaluation of Heat Recovery Ventilator According to Outdoor Conditions)

  • 김광현;이정재
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.57-64
    • /
    • 2008
  • Recently, regulation of ventilator installation and its details has been revised and the establishment of heat recovery ventilator in newly built apartments has been obligated. This study was done to offer the method of operation and design of heat recovery ventilator to save energy by measuring its efficiency and comparing with the results of experiment. This paper confirmed that it is desirable to operate heat recovery ventilator by using "by-pass mode" within $60{\sim}80%$ scope of the difference indoor absolute humidity in spring and autumn and outdoor absolute humidity and heat recovery ventilator of energy saving effect is better than constant air volume system.