A Sbjective Symptom on Outdoor Air Quality in Dental Hygienist (대기오염에 의한 치과위생사의 자각증상 특성)

  • Ji, Dong-Ha;Choi, Mi-Suk;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2007
  • This research is based on self-filling survey which 656 dental hygienists who work in, seoul, the metropolitan area, jeon-buk area participated on July 2006 through August 2006. This survey was analyzed the relationship between the subjective symptoms(6 types) and outdoor air quality($O_3,\;NO_2,\;CO,\;SO_2,\;PM_{10}$) As follows analyzed results. The health condition of dental hygienists were "Feel Good" more than 50% in last month. The experience the symptoms level is higher then non-experience level in "Dry eye, itch, smarting", "Headaches", "Fatigue and sleepiness", "Red eye", "Hypersensitivity", "Dorsalgia, omarthralgia, cervicodynia". We anticipated that the more experience the subjective symptom the more likely it is that outdoor air quality will be high rate level. But we could not find the uniformity in metropolitan-area and seoul-area. In the case of jeonbuk area, the group's pollution density levels which experienced the subjective symptom were appeared high rate than inexperienced group except $SO_2$. It probably comes from sensibility for an air pollution in this area. Dental hygienists who work in jeonbuk area have an unusual sensibility for an air pollution because outdoor air quality of jeonbuk area was rule good rather than others area. especially $SO_2$ was revealed out even though low rate level in inexperienced group it is that the number of cars in jeonbuk area is increasing rapidly.

Numerical Analysis on Energy Consumption of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지소비 수치해석)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Kim, Hyoung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1306-1311
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, in order to improve clean room air quality, air washers are used to remove airborne gaseous contaminants such as $NH_3$, SOx and organic gases from the outdoor air introduced into clean room. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery is therefore useful for reducing the outdoor air conditioning load for a clean room. Therefore it is desirable to recover heat from the exhaust air and use it to reheat the outdoor air. In the present study, numerical analysis and experiment was conducted to simulate the amount of energy reduction of exhaust air heat recovery type air washer system. The present numerical results showed good agreement with the results of the experimental data.

  • PDF

Evaluation of Indoor Air Quality Improvement by Formaldehyde Emission Rate in School Indoor Environment Using Mass Balance (물질수지를 이용한 학교 실내환경의 포름알데히드(HCHO) 배출량 산정에 의한 실내공기질 개선 평가)

  • Yang, Won-Ho;Son, Bu-Soon;Kim, Dae-Won;Kim, Young-Hee;Byeon, Jae-Cheol;Jung, Soon-won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.160-165
    • /
    • 2005
  • Schools have significant and serious indoor environmental health problem, of which indoor air quality (IAQ) in school building may affect the health of the students and indirectly affect learning performance. Schools are of special concern when regarding indoor exposure to air pollutants, because students are particularly sensitive to pollutants and spend a significant amount of time in that environment. Therefore researches for improvement of indoor air quality have been developed such as installation of air cleaning device, ventilation system, titanium dioxide(TiO2) coating and so on. However, it is difficult to evaluate the magnitude of improvement of indoor air quality in field study because indoor air quality can be affected by source generation, outdoor air level, ventilation, decay by reaction, temperature, humidity, mixing condition and so on. In this study, evaluation of reduction of formaldehyde emission rate in school indoor environments by far-Infrared ray coating material was carried out using mass balance model in indoor environment. we proposed the evaluation method of magnitude of improvement in indoor air quality, considering outdoor level and ventilation. Since simple indoor concentration measurements could not properly evaluate the indoor air quality, outdoor level and ventilation should be considered when evaluate the indoor air quality.

An Analysis about Recognition of Indoor Air Quality of Workers at Dental Clinics in Jeollanamdo Area

  • Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.137-142
    • /
    • 2018
  • The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

A Study on the Characteristics of Heavy Metal Concentration and Indoor Atmospheric Environments ; Heavy Metal Concentration in School Environments (실내 대기환경과 중금속농도의 분포특성에 관한 연구 - 학교 환경의 중금속농도)

  • 박종길;장난심
    • Journal of Environmental Science International
    • /
    • v.6 no.5
    • /
    • pp.451-459
    • /
    • 1997
  • This paper alms to describe the indoor-outdoor air quality in school environment through the analyses of heavy metal concentration by inductively Coupled Plasma(ICPI, which were observed at some school environment, such as traffic area, industrial area seme-industrial area, and residence area. The results are as follows : (1) Regardless Indoor and outdoor, the area with the highest concentration of heavy metal is industrial area followed by traffic area, residence area and semi-industrial area in descending order of magnitude. And the heavy metal concentration of indoor is higher than that of outdoor. (2) The main heavy metal components with more high level concentration of Indoor than those of outdoor are Zn, Al, Ca and these heavy metal concentrations are higher in class than In corridor and outdoor.

  • PDF

Indoor Air Quality of Acidic Air Pollutants at a Private House in Seoul During the Spring Months

  • Lee, Hak-Sung;Kang, Byung-Wook;Kang, Choong-Min;Yeo, Hyun-Gu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E3
    • /
    • pp.109-115
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality at a private house in Seoul during the spring period. All indoor and outdoor samples were measured simultaneously using an annular denuder system. The data set was collected on twelve different days with a 24-hr sampling period in April and May 1997. The chemical species measured were HN $O_3$, HN $O_2$, S $O_2$ and N $H_3$in the gas phase and P $M_{2.5}$ (dp 2.5 ${\mu}{\textrm}{m}$), S $O_4$$^{2-}$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ in the particulate phase. Indoor concentrations of HN $O_2$, N $H_3$, and P $M_{2.5}$ were greater than outdoor levels. However, indoor concentrations of HN $O_3$, S $O_2$, N $O_3$$^{[-10]}$ and N $H_4$$^{+}$ were less than those found from outdoors. In the case of S $O_4$$^{2-}$, the indoor and outdoor concentrations were similar. Indoor concentrations of P $M_{2.5}$ , S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were dependent upon the outdoor concentrations. A tracer-gas decay technique with sulfur hexafluoride (S $F_{6}$ ) as the tracer gas was used to estimate the air exchange rate of a private home in the spring. The average air exchange rate was computed to be 2.87 h $r^{-1}$ .X> .

  • PDF

Influence on the Indoor Air Quality by Ambient Air during the Summer Season (여름철 실외 공기가 실내 공기질에 미치는 영향)

  • 이학성;강병욱
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.637-644
    • /
    • 1997
  • The purpose of thins study was to quantitatively determine the Indoor Infiltration of pollutants of outdoor origin. The relationship between Indoor and outdoor air is dependent, to a large extent. on the rate of k exchange between these two environments. Mean Indoor/outdoor ratios measured from thins study were: 0.70 for HNO3; 1.60 for HNO2: 0.56 far SOg: 1.30 for mf3: 0.96 for PM2.5(dP<2.5mm: 0.89 for SO4a': 0.87 for NO3· and 0.79 for NH4 'Mean Indoor concentrations for PMa s, SO4a., HNO9, NO3 and NIL' were similar to outdoor levels. Indoor HNO2 and mB3 values were h19her than outdoors. However, the Indoor level of SO2 was lower than ambient level.

  • PDF

Air Pollution prediction at Highway Tollgate by Using Real Time Traffic Volume (실시간 교통량을 이용한 고속도로 요금소 대기요염도 예측)

  • 박성규;김신도;이정주
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.134-140
    • /
    • 2000
  • The increase in traffic is a worldwide phenomenon. In Korea, it has been increased by 20% per annual in recent 1990’s and approximately 10 millions cars had been registered until 1997. This traffic could easily affect and contribute the local outdoor air quality(QAQ) concerned. The QAQ in highway in one of the examples and the subject in this study. The seoul tollgate located at the north-end of Keypngbu Highway was selected for the study. In case of highway tollgate, the local air pollution could be directly affected by the traffic to approach, wait and start the tollgate. Nitrogen dioxide (NO$_2$) concentration exceeded the EAQS(Environmental Air Quality Standards), but overall indoor air quality was a little better than the outdoor air quality. The measured TSP concentration was much higher than that of the EAQS. To apply a management to a air quality problem of Seoul tollgate, it was predicted air quality with traffic volume and weather condition. It was calculated NO$_2$ emission with traffic volume and predicted in and out of booth by CALINE3 at the Seoul tollgate. To make a comparison between measured and predicted concentration, the prediction was good. It was shown that NO$_2$ concentration was high in the morning at the from Seoul direction and in the evening at the to Seoul direction. it was thought that NO$_2$ concentration variation was reflected according to the traffic volume.

  • PDF

Characteristics of Indoor Air Quality of Acidic Air Pollutants in a Private Home During Home During the Summer Season (여름철 가정집에서의 산성오염물질에 대한 실내 공기질 특성)

  • 이학성;강병욱;강충민;여현구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.193-201
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality in a residential area in the summer. All indoor and outdoor samples were measured simultaneously using an annular denuder system(ADS) in Seoul. The data set was collected from July 26 to September 11, 1997. The mean indoor/outdoor ratios measured from this study were : 0.34 for $HNO_3$; 0.91 for $HNO_2$; 0.22 for $SO_2$; 1.34 for $NH_3$; 0.78 for $PM_{2.5}(d_p$ <2.5 $mutextrm{m}$); 0.90 for $SO_{4}^{2-}$; 0.68 for $NO_{3}^{-}$ and 0.79 for $NH_{4}^{+}$. Indoor concentrations of $HNO_3$, $SO_2$ and $PM_{2.5}$ were highly correlated with the outdoor concentrations. The relationship between indoor and outdoor air is dependent, to a large extent, on the rate of air exchange between these two environments. A tracer-gas decay technique with sulfur hexafluoride ($SF_{6}$) as a tracer gas was used to estimate the air exchange of a private home in the summer. The average air exchange rate was estimated to be 23.7 hr(sup)-1. The deposition velocities for $SO_{4}^{2-}$, $NO_{3}^{-}$ and $NH_{4}^{+}$ calculated were 0.17, 0.69 abd 0.39 cm/sec, respectively.