• Title/Summary/Keyword: outdoor air quality

Search Result 208, Processing Time 0.024 seconds

Assessment of indoor ventilation in commercial office buildings (업무용 빌딩 소재 사무실의 실내환기 평가)

  • Jeong, Jee Yeon;Lee, Gwang Yong;Lee, Byung Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • In winter season, the survey was performed in three commercial office buildings in the metropolitan Seoul, Pusan, and Gwangju city. The purpose of the survey was to evaluate the effectiveness of ventilation for offices in commercial buildings. The data were compared to standard of applicable to the indoor ventilation in office. The results indicated that the most commercial office buildings used the air handing unit and fan coil unit as HVAC system, and the intake amount of fresh outdoor air were very inadequate to compared to the ASHRAE standard value of $0.57\;m^3/min/person$. Also the surveyed all commercial office building used the HVAC system as a meas of controlling temperature for office indoor air. Ultimately, these results presented that there were possibility of evoking indoor air quality problems by the insufficient ventilation.

A Development of Partition Wall for enhenced Sound Transmission Loss and Air Tightness (차음성능과 기밀성능이 향상된 경량 간막이벽 개발)

  • 배상환;박진우;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.855-860
    • /
    • 2001
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings. it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But. the required performances of a light-weight wall are not evaluated systematically. As a field survey result. partition walls of house-to-house and room-to-room were not showed their respected performances. so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially. occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Also to suppress indoor air movement. stact effect must be concerned. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings.

  • PDF

The Study on Concentration of PM10 and Heavy Metal in Public Schools at Chung-Nam Area (충남 지역 일부 학교의 PM10과 중금속 농도에 관한 연구)

  • Son, Bu-Soon;Song, Mi-Ra;Kim, Jung-Duk;Cho, Tae-Jin;Yang, Won-Ho;Chung, Tae-Woong
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.1005-1013
    • /
    • 2008
  • In this study, in order to analyze the air quality of the indoor environments of schools, we measured the indoor, outdoor and personal exposure concentration level of $PM_{10}$ for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003. 1. Old classrooms contained more dust than new classrooms; the average of respirable dust is $43.27\;{\mu}g/m^3$ for new classrooms while $53.38\;{\mu}g/m^3$ for old one. The exposure concentration level of respirable dust in new classrooms were in summer higher outdoors than indoors. The values were indoors $46.71\;{\mu}g/m^3$, outdoors $50.46\;{\mu}g/m^3$, and personal $41.62\;{\mu}g/m^3$. Meanwhile in winter indoors had a higher concentration level than outdoors, the values being indoors $39.11\;{\mu}g/m^3$, outdoors $34.86\;{\mu}g/m^3$, and personal $49.01\;{\mu}g/m^3$. 2. Cr concentration level within dust was slightly higher in summer indoors ($101.50{\pm}32.10\;ng/m^3$) and outdoors ($100.89{\pm}35.18\;ng/m^3$) than winter indoors ($85.80{\pm}48.95\;ng/m^3$) and outdoors ($74.43{\pm}38.93\;ng/m^3$), but in personal concentration level, winter was higher. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. As such, a logical and systematic education program for students about the importance of indoor air quality should be carried out. Also the results of $PM_{10}$ concentration level measurements emphasize the need for regular measurements of indoor / outdoor and personal concentration level. New classrooms in particular needs to be used after measuring pollutants and safety, and requires installation of a ventilation device in all classrooms to improve air quality.

Air Contamination in an Underground Commercial Floor assayed by GAseous Pollutants, Dusts and Mutagenicity (빌딩 地下商街의 空氣性狀 및 분자의 變異原性)

  • 兪榮植
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.46-52
    • /
    • 1987
  • There are many factors such as airtighteness and high density of merchandises or passengers that contaminate indoor air in underground commercial floor. So it is very important to know air quality and quantity of contamination in underground market increasing in number lately. It was from these viewpoints that gaseous pollutants, dusts and mutagenicity of organic compounds extracted from dusts in an underground market were investigatd. Organic ompounds (tar) were extracted by Soxhlet extractor with benzene as a solvent. Mutagenicities of these extracts were evaluated by the preincubation method using Salmonella typhimurium TA 100 and TA 98 strains with and without S9mix. The results obtained were as follows: It seemed to be under the influence of outdoor air that the concentrations of $CO, CO_2, NO, NO_2$ and dusts were higher in winter than summer. The concentration of $CO_2$ was higher in indoor than outdoor, but the concentration of NOx was similar in both sampling areas. Metal contents in dusts attached to the ventilation ducts were as follows showing in order of high concentration : Fe (9000-22000ppm), Zn(1200-2300ppm) and Pb (280-590ppm). The contents of tar were 6-33% of dusts, and higher than those from dusts collected by high volume air sampler. The extracts from dusts attached to the inlet duct exhibited lower mutagenicity than those from dusts attached to the outlet duct. This finding seemed to suggest that mutagenic substances were in creasing in underground. There was no seasonal difference of mutagenicity toward TA 98. Toward TA 100 in the presence of S9mix, the mutagenicity was about 3 fold higher in winter than summer. The mutagenicities of tar extracted from dusts collected by high volume air sampler were different from those attached to the ventilation ducts. The former showed 2-3 fold higher mutagenicity than the latter toward TA 100. However no difference showed between the former and the latter toward TA 98 in the absence of S9mix, but the former was 4-5 fold higher than the latter in the presence of S9mix.

  • PDF

Indoor to Outdoor Ratio of Fine Particulate Matter by Time of the Day in House According to Time-activity Patterns (시간활동양상에 따른 주택의 시간대별 실내·실외 초미세먼지 농도비)

  • Park, Jinhyeon;Kim, Eunchae;Choe, Youngtae;Ryu, Hyoensu;Kim, Sunshin;Woo, Byung Lyul;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.5
    • /
    • pp.504-512
    • /
    • 2020
  • Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the 'Time-Use Survey' data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multifamily housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 ㎍/㎥, respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.

Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces (경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인)

  • Park, Hee-Eun;Park, Jeong-Ho;Kim, Hyoung-Kab
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.119-127
    • /
    • 2012
  • Objectives: The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods: This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results: 1. The average indoor airborne concentrations of total fiber particles were $0.0011{\pm}0007$ f/cc in schools and $0.0015{\pm}0007$ f/cc in public facilities by PCM. Over 90% of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were $0.0007{\pm}0002$ f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions: The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.

Properties of Fine Dust Adsorption Matrix Based Blast Furnace Slag using Bentonite (벤토나이트를 활용한 고로슬래그 기반 미세먼지 흡착형 경화체의 특성)

  • Kim, Yeon-Ho;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.40-41
    • /
    • 2019
  • Fine dust, which is emerging as a global problem, attracted much attention recently in Korea. One of the reasons is that recent factory relocation and expansion in China affected the increase of domestic fine dust concentration due to the influence of the Yangtze river battalion and westerlies. Fine dust is a big problem not only in outdoor but also indoors. The room requires periodic ventilation and is also essential for improving indoor air quality. The fine dusts are designated as Group 1 carcinogens in WHO and the risk of fine dusts on the human body due to respiratory diseases is also increasing. In this study, the characteristics of the fine dust adsorption matrix are examined and the actual application direction is derived.

  • PDF

Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses (신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가)

  • Kim, Young-Hee;Yang, Won-Ho;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

Indoor and Outdoor Formaldehyde Concentrations in Underground Environments (실내외 포름안데히드 농도에 관한 조사연구)

  • 김윤신;김미경
    • Journal of Environmental Health Sciences
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 1989
  • A pilot study was conducted in order to measure indoor and outdoor formaldehyde levels during August 3 - 22, 1988 in several underground spaces in Seoul. Formaldehyde concentrations were monitored during 1 week in selected sampling areas (subway station, underground shopping center, underpass, tunnel, underground parking lot) using passive formaldehyde monitors. In order to investigate a relationship between respiratory prevalence and levels of formaldehyde, each subject was asked to answer respiratory questions. The mean formaldehyde concentrations were 60.1 ppb in subway station, 122.2 ppb in underground shopping stores, 72.1 ppb in underpasses, 39.7 ppb in tunnel, and 75.9 ppb in underground parking lots, respectively. The mean indoor formaldehyde concentrations in underground environments varied from 28.6 ppb to 118.7 ppb. Generally, the mean formaldehyde concentrations in ticketing office in subway stations appeared higher than those level measured in platform. The mean formaldehyde concentrations of underground shopping center in Gangnam Terminal were higher than any other areas and it exceeded 100 ppb of the American Ambient Air Quality Standards of formaldehyde. Prevalence rates of respiratory symptoms of dwellers seemed to be related to higher indoor formaldehyde levels.

  • PDF

A Survey of Characterization Airborne Bio-aerosol Concentration in Public Facilities

  • Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Choel-Min;Jun, Hyung-Jin;Kim, Jong-Choel;Song, Min-Kyung
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.273-278
    • /
    • 2005
  • This study was performed to investigate the characteristics of distribution for airborne bio aerosol in 11 public facilities in Seoul from June to July. The collected samples are total suspended bacteria in indoor and outdoor Anderson six stage air sampler by the IAQ standard method of Ministry of Environment in Korea. The concentration of total suspended bacteria in the theater higher than IAQ standards. As the results of the survey, the most high indoor air mean concentration of bacteria $1273CFU/m^3$ was theater and the most high outdoor air mean concentration of bacteria $^229 CFU/m3$was Kindergarten. The mean concentration of bacteria in the theater was higher than the IAQ standards established by the Ministry of Environment, Republic of Korea. Moreover, this study was for investigation a part of indoor air pollution condition in public facilities. It means that this study can't represent fDr all of public facilities. Therefore, we suggest that long and middle term country plan for management of IAQ should be established through long-term and continuous investigation of IAQ condition. Also above consideration in mind, it is suggest that the research for source contribution of the results on these need further study.

  • PDF