• 제목/요약/키워드: out coupling

검색결과 627건 처리시간 0.039초

구조물 연결부의 질량부과 효과 : SEA실험 및 해석 결과 비교 (Added Mass Effect on Structural Junction: Comparison of SEA Experimental Results with Analysis)

  • 김관주;김정태;윤태중;박봉현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.359-364
    • /
    • 2002
  • Statistical energy method is widely used for the prediction of vibrational and acoustical behavior of complex structures, such as ship building and automobile in mid-, high frequency ranges. However. in order to convince this SEA result, it is important to verify estimated SEA parameters, e. g. modal density, energy in each subsystem, damping loss factor, coupling loss factor. with possible other method. For modal density parameter, the experimental estimations via Experimental Modal Analysis are checked with those from finite element method for both beam- plate and plate-plate cans. Loss factors are calculated by Lyon's simple method for the two subsystem. finally. modal experiments are carried out by varying the mass added on the junction of two subsystem for the purpose of investigating the influence on the coupling loss factor's behavior.

  • PDF

운동부하가 움직임-호흡 결합에 미치는 영향 (Effect of the Exercise Load on the Locomotor-Respiratory Coupling)

  • 남궁영;박은영;박호준
    • 한국전문물리치료학회지
    • /
    • 제5권3호
    • /
    • pp.56-62
    • /
    • 1998
  • The nature of entrainment between the locomotor and the respiratory rhythm was investigated while normal human subjects were walked or running on a treadmill. The purpose of this study was to analyze the incidence and type of coordination between the locomotor and the respiratory rhythm during running at different work load. The experiments were carried out on 12 untrained volunteers exercising at 3 work loads (2 METs, 3 METs, 4 METs in randomized order). The gait cycle was measured by electromyography (EMG) signal of gastrocnemius firing and the respiratory cycle was measured by a thermometer. We found that the ratio between the locomotor and the respiratory rhythm existed and 2:1 ratio between the locomotor-respiratory coupling was dominant at 2 METs and 3 METs.

  • PDF

NiO Thickness Dependences of Perpendicular Magnetic Anisotropy in the [CoFe/Pt] Multilayers

  • Kim, S.W;Lee, J.Y;Lee, S.S;Hahn, E.J;Hwang, D.G
    • Journal of Magnetics
    • /
    • 제9권4호
    • /
    • pp.121-124
    • /
    • 2004
  • NiO thickness dependences of perpendicular magnetic anisotropy (PMA) in the $NiO/[CoFe/Pt]_5$ multilayers for exchange biasing and $[CoFe/Pt]_4/Pt/[CoFe/Pt]_4$ for interlayer exchange coupling were investigated. Perpendicular magnetization curve was obtained by out-of-plane extraordinary Hall measurement. Magnetic force microscopy (MFM) has been used for the investigation of magnetic domains on thin films. We confirmed that the interlayer exchange coupling (IEC) as a function of NiO thickness at room temperature existed with a period of two monolayers.

부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가 (Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement)

  • 박대원;최수연;최재성;길경석;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

2D Finite element analysis of rectangular water tank with separator wall using direct coupling

  • Mandal, Kalyan Kumar;Maity, Damodar
    • Coupled systems mechanics
    • /
    • 제4권4호
    • /
    • pp.317-336
    • /
    • 2015
  • The present paper deals with the analysis of water tank with elastic separator wall. Both fluid and structure are discretized and modeled by eight node-elements. In the governing equations, pressure for the fluid domain and displacement for the separator wall are considered as nodal variables. A method namely, direct coupled for the analysis of water tank has been carried out in this study. In direct coupled approach, the solution of the fluid-structure system is accomplished by considering these as a single system. The hydrodynamic pressure on tank wall is presented for different lengths of tank. The results show that the magnitude of hydrodynamic pressure is quite large when the distances between the separator wall and tank wall are relatively closer and this is due to higher rotating tendency of fluid and the higher sloshed displacement at free surface.

Wear Characteristics and Thermal Stability of PA66/silane treated MoS2 Composites

  • Nam, Ki-dong;Gu, Bo-ram;Ryu, Sung-hun
    • Elastomers and Composites
    • /
    • 제55권4호
    • /
    • pp.339-346
    • /
    • 2020
  • We functionalized a wear-resistant carbon-based MoS2 filler to solve its limited wear condition problem. The filler exhibits excellent lubricative properties. The surface modification of MoS2 was carried out using a (3-glycidyloxypropyl)trimethoxysilane (GPTMS) silane coupling agent to improve the low compatibility and dispersibility of the filler that generally degrade the performance of composites. A silane coupling agent was employed for the functionalization of MoS2, and its effect on the wear resistance of MoS2/Polyamide-6,6 was investigated. The silanization of MoS2 was identified by contact angle analysis and Fourier-transform infrared, energy dispersive X-ray, and X-ray photoelectron spectroscopies. The wear resistance of the composite was found to be improved significantly by the surface functionalization of MoS2.

폐 FRP/석분슬러지 충전 복합재의 제조 및 기계적 물성에 관한 연구 (A Study on the Preparation ana Mechanical Properties of Composites Reinforced FRP Waste and Rock-Crush Sludge)

  • 황택성;박진원;이철호
    • 폴리머
    • /
    • 제24권6호
    • /
    • pp.829-836
    • /
    • 2000
  • SMC 욕조 생산 시 발생하는 폐 FRP와 석재 가공공정에서 발생되는 석분슬러지를 재활용하기 위하여 불포화에스테르 매트릭스 수지에 분말 충전하여 복합재를 제조하였다. 또한 충전제와 매트릭스 간의 계면결합력을 향상시키기 위해 석분을 실란 커플링제 ${\gamma}$-methacryloxypropyltrimethoxysiiane (${\gamma}$-MPS)로 전처리하여 복합재를 제조하고 기계적 물성 및 계면현상을 관찰하였다. 복합재의 굴곡탄성율은 석분함량이 10 wt%, 실란커플링제의 농도가 3 wt%일 때 가장 우수하였으며 석분 충전량이 증가함에 따라 감소하는 경향을 보였다. 또한 복합재의 초기 열분해온도는 352~359$^{\circ}C$이었으며 이 온도에서 중량감소율은 약 3%로 충전제의 양에 관계없이 거의 일정한 경향을 보였다. ${\gamma}$-MPS 처리에 따른 복합재의 물성변화를 관찰한 결과 충전제와 매트릭스 수지간 계면결합력이 증진되어 물리 화학적으로 안정한 결합을 이루고 있고 pull out현상이 발생하지 않음을 확인할 수 있었다.

  • PDF

Design and Analysis of Diffractive Grating Imprinted Light-guide Plate for LCD Illumination

  • Choi, Hwan-Young;Park, Young-Pil
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.7-15
    • /
    • 2004
  • A highly simplified backlight unit mainly composed of diffractive grating in sub-micron order imprinted light-guide plate (LGP) is proposed for edge-lit backlight unit. Optical characteristics of the imprinted LGP are examined by RCWA and the performance is verified through Monte Carlo simulation. Results show that the diffraction efficiency, luminous flux and its uniformity over the area are significantly affected by the angle of incident ray. Consequently couples of design considerations are additionally proposed to enhance luminous flux. In terms of peak luminance and out-coupling luminous flux, the experimental results are agreed well with the performance simulation. Finally, compared with optical characteristics of conventional backlight unit, we could conclude that the proposed simplified backlight unit made of diffractive grating imprinted light-guide plate is a good substitute for the conventional backlight unit.

Synthesis, X-Ray Crystal Structure and Coupling Reactions of 4,5-($1^{\prime},2^{\prime}$-diphenylethylenedithio)-1,3-dithiole-2-thione (dPhEDT-DTT)

  • 이하진;노동윤
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권3호
    • /
    • pp.340-344
    • /
    • 1998
  • A facile synthesis of 4,5-(1',2'-diphenylethylenedithio)-1,3-dithiole-2-thione (dPhEDT-DTT) is carried out via a Diels-Alder type [2+4] cycloaddition reaction of 1,3-dithiol-2,4,5-trithione oligomer and t-stilbene. Molecular structure of dPhEDT-DTT is determined by x-ray crystallography: space group P1, a=11.694(3) Å, b=12.117(3) Å, c=14.688(3) Å, α=113.12(2)°, β=102.23(2)°, γ=107.02(2)°, V= 1699.1(7) Å3, Z=2. It turns out that dPhEDT-DTT crystallizes as a racemic compound consisting of (R,R) and (S,S) enantiomers. Coupling reaction of dPhEDT-DTO undergone in neat P(OEt)3 yields TTF(SEt)4 instead of ET derivative. When PR3 (R=OEt, OPh, Ph) is used in benzene, toluene or xylene, however, dPhEDT-DTO is decomposed.

삼상 분리형 자속커플링 전류제한기의 턴 수의 따른 전류제한 특성 (Characteristics according to turn ratio of Separated Three-Phase Flux-Coupling Type Superconducting Fault Current Limiter(SFCL))

  • 김용진;두호익;두승규;김민주;이동혁;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.344-345
    • /
    • 2009
  • The flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO coated conductor was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics according to turn ratio in the flux-coupling type SFCL. The experiment results that the fault current limiting characteristics was improved according to turn ratio.

  • PDF