• Title/Summary/Keyword: osseointegration.

Search Result 398, Processing Time 0.028 seconds

Bone-like Apatite Formation on Ultrafine-Structure in Modified Electrolytic Solution

  • Jang, Jae-Myung;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.155-155
    • /
    • 2017
  • Surface modifications are commonly utilized to adjust the properties of the titanium and its alloy surface to the specific needs of the medical applications, but there are disadvantages such as poor osteoconductive properties and low adhesion of bone cell to implant surface. In order to improve these disadvantages, changes in surface properties have an important effect on osseointegration during implantation. In this paper we applied new technological method for improving a unique surface modification using the characteristic of an electrolytic Solution. Thus, in the electrolyte containing NaF in Na2SO4, TiO2 nanoporous was uniformly formed, and HAp nanoparticles were electrodeposited around the TiO2 nanopores, but in the electrolyte containing NH4F in (NH4)H2PO4, the coarse protrusions including HAp nano particles were regularly deposited onto the TiO2 barrier layer. The surface characteristics and the distributed elements and have been investigated by EDS analysis, and ultra-fine structure of surface are carried out using FE-SEM. To investigate the behavior of the anion, the analysis of chemical states was performed by XPS, and the narrow spectrums for Ti2P, Ca 2p, and P 2p seems to be almost similar depending on the characteristics of the electrolyte solution respectively. In addition, Ca 2p spectrum could be resolved into two peaks for Ca 2p3/2 and 2p1/2 at 347.4 and 351.3 eV, which are related to hydroxyapatite. And, the P peak can also be deconvoluted into two peaks for P1/2 and P3/2 levels with binding energy 134.2 and 133.4 eV, respectively. From the result of soaking test, the apatite morphologys were well-formed onto the modified surface according to the different conditions.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE (골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구)

  • Jang, Kyoung-Soo;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF

THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT (임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구)

  • Lim, Jae-Bin;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

The Effect of a Shock-Absorbable Polymer(Chitosan) on the Initial Stability and Dynamic Behavior of Dental Implant (충격흡수용 고분자재료의 이용이 Implant 초기안정성과 동적거동에 미치는 영향)

  • Joo, W.;Choi, K.;Kwon, I.C.;Choi, J.B.;Moon, H.J.;Shin, J.W.;Lee, Y.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.337-342
    • /
    • 1997
  • Dental implant has been increasingly used to recover the masticatory unction of tooth. It has been well known that the success of dental implant is heavily dependent on initial stability and long-term osseointegration due to optimal stress distribution in the surrounding bones. The role of periodontal ligament, removed during operation, is to absorb impact force and to distribute them to alveolar bone. or this reason, the study for artificial periodontal ligament has become an important issue in this field. In this study, chitosan was coated on dental implant or the purpose of replacing the role of intact periodontal ligament. The results by experiment and FEM analysis showed : I) Initial stability of dental implant was significantly increased(35%) when the implant was coated with chitosan. II) The coated implant showed higher impact absorption, more even stress distribution and lower stress magnitude under impact force than uncoated implant. Accordingly, the micro-fracture of the surrounding bones due to impact force would be lessened by chitosan coating on dental implant.

  • PDF

Mandibular Reconstruction and Dental Implantation after Segmental Mandibulectomy of Ameloblastoma of the Mandible (하악골 법랑질모세포종의 분절 하악절제술 후 하악 재건 및 치아 임플란트 시술)

  • Seo, Seung-Jo;Lee, Il-Jae;Lee, Jung-Geun;Lim, Hyo-Seob;Kim, Chee-Sun;Park, Myong-Chul
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.212-216
    • /
    • 2011
  • Purpose: Ameloblastomas are rare benign tumors of odontogenic origin, and compose about 1% of all oral and maxillomandibular cysts and tumors. Because this neoplasm has a high rate of local recurrence, segmental mandibulectomy with a 1~2 cm safety margin and immediate microsurgical reconstruction is an accepted treatment modality. The authors experienced four mandibular reconstruction cases that underwent secondary dental implantation. Here, the authors describe these cases and their long-term results. Methods: Four patients with ameloblastoma of the mandible underwent segmental mandibulectomy and reconstruction with a free fibula osseous flap from January 1999 to May 2005, followed by secondary dental implantation. Recurrence, bony union, implant osseointegration, and functional and aesthetic results were evaluated by radiologic imaging, by physical examination, and by using photographs. Results: All free flaps survived with no evidence of flap loss. To date, no recurrence has been noted clinically or radiologically. Imaging after mandibular reconstruction with a free fibular flap revealed satisfactory bony unions and mandibular contours. The patients achieved good aesthetic and functional results after the secondary implantation. Conclusion: Mandibular reconstruction using a fibular osseous flap and secondary dental implantation can produce good functional and aesthetic results after segmental mandibulectomy for ameloblastoma.

Effect of implant surface microtopography by hydroxyapatite grit-blasting on adhesion, proliferation, and differentiation of osteoblast-like cell line, MG-63

  • Park, Sung-Jae;Bae, Sang-Bum;Kim, Su-Kyoung;Eom, Tae-Gwan;Song, Seung-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.3
    • /
    • pp.214-224
    • /
    • 2011
  • Objective: This study examined the potential of the in vitro osteogenesis of microtopographically modified surfaces, RBM (resorbable blasting media) surfaces, which generate hydroxyapatite grit-blasting. Methods: RBM surfaces were modified hydroxyapatite grit-blasting to produce microtopographically modified surfaces and the surface morphology, roughness or elements were examined. To investigate the potential of the in vitro osteogenesis, the osteoblastic cell adhesion, proliferation, and differentiation were examined using the human osteoblast-like cell line, MG-63 cells. Osteoblastic cell proliferation was examined as a function of time. In addition, osteoblastic cell differentiation was verified using four different methods of an ALP activity assay, a mineralization assay using alizarin red-s staining, and gene expression of osteoblastic differentiation marker using RT-PCR or ELISA. Results: Osteoblastic cell adhesion, proliferation and ALP activity was elevated on the RBM surfaces compared to the machined group. The cells exhibited a high level of gene expression of the osteoblastic differentiation makers (osteonectin, type I collagen, Runx-2, osterix). imilar data was represented in the ELISA produced similar results in that the RBM surface increased the level of osteocalcin, osteopontin, TGF-beta1 and PGE2 secretion, which was known to stimulate the osteogenesis. Moreover, alizarin red-s staining revealed significantly more mineralized nodules on the RBM surfaces than the machined discs. Conclusion: RBM surfaces modified with hydroxyapatite grit-blasting stimulate the in vitro osteogenesis of MG-63 cells and may accelerate bone formation and increase bone-implant contact.

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

Observation of the change of the dental implant stability and bone density evaluation methods (골밀도 평가방법과 임플란트 안정성 변화의 관찰)

  • Ko, Sok-Min;Park, Sung-Jae;Kim, In-Soo;Song, Seung-Il;Lee, In-Kyung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.2
    • /
    • pp.185-192
    • /
    • 2009
  • Purpose: The aim of this study was to examine the correlation of the subjective and the objective evaluation of edentulous ridge bone quality, and to evaluate the change of the dental implant stability in each bone density group for early healing period after implant installation. Methods: Sixty-seven implants(Osstem implant$^{(R)}$, Seoul, Korea) were included in this study. We evaluated the bone density by 2 methods. The one was the subjective method which was determined by practitioner s tactile sense, the other was the objective bone type was based on Hounsfield units. The implant stability in each bone type group was assessed by resonance frequency analyzer(Osstell mentor$^{(R)}$). Data were analyzed for the change of the implant stability, and they were compared to verify the difference of groups at the time of installation, 2, 6, 10, 14 weeks postoperatively. Spearman's correlation was used to demonstrate the correlation between the subjective and the objective evaluation of the bone density, and analysis of variance(ANOVA) was used to analyze the differences of implant stability at each time point. Results: There was no close relation between the subjective and the objective evaluation of the bone density(r=0.57). In the subjective groups, there was statistically significant difference between the type 1 and 3 at 10 weeks and between the type 2 and 3 at 14 weeks. In the objective groups, there was no statistically significant difference between the D 1, 2, 3, 4, and 5 group with regard to RFA from baseline to 14 weeks(P>0.1). Conclusions: The implant stability increased over time during the study, and it was improved with bone density proportionally after 2weeks postoperatively. It is recommended that the decision of bone density is base on Hounsfield unit for implant loading time.

Applications of Non-Thermal Atmospheric Pressure Plasma in Dentistry (상온 대기압 플라즈마의 치의학적 응용)

  • Uhm, Soo-Hyuk;Kwon, Jae-Sung;Lee, Eun-Jung;Lee, Jung-Hwan;Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.783-794
    • /
    • 2014
  • Since the introduction of non-thermal atmospheric pressure plasma in the field of the dentistry, numerous applications have been investigated. Especially with its advantages over existing vacuum plasma in terms of portability, low cost, and non-thermal damage, it can be directly applied in the oral cavity, giving number of potentials for dental application. First, possible application of non-thermal atmospheric pressure plasma in the field of dentistry is relation to dental caries and periodontal diseases. Teeth and alveolar bones are one of the strongest bony structures in our body, but it cannot be regenerated when they are damaged by dental caries or periodontal disease. Hence many studies to prevent such diseases have been carried out, though no perfect solution has been found yet. With recent studies of modifying surfaces through non-thermal atmospheric pressure application that can prevent attachment of bacteria, or studies on bactericidal effects of non-thermal atmospheric pressure plasma can be applied here to prevent oral pathogen and 'biofilm' attachment to the surface of teeth or directly eliminate the dental caries/periodontal disease causing germs. Secondly, non-thermal atmospheric pressure application will be useful on the surface of dental implant. It is well known that the success of dental implant surgery depends on the process known as 'osseointegration' that result from osteoblast attachment, proliferation and differentiation. As the application of non-thermal atmospheric pressure plasma on the surface of dental implant just before its introduction by the chair-side of dental surgery. Despite its long history, the generation of non-thermal atmospheric pressure plasma has been greatly increased with its application in dentistry.

Finite Element Analysis of Stress Distribution on Supporting Bone of Cement Retained Implant by Oblique Loading (경사하중에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분포)

  • Lee, Myung-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.343-349
    • /
    • 2014
  • The dental osseointegration implant should be enough to endure occlusion load and it's required to have efficient design and use of implant to disperse the stress into bones properly. Solidworks as a finite element analysis program for modeling and analysis of stress distribution was used for the research. The simple crown model was designed on applying conjoined condition with tightening torque of 20 Ncm of a abutment screw between a cement retained implant abutment and a fixture. A $45^{\circ}$ oblique loading from lingual to buccal side on buccal cusps of crown and performed finite element analysis by 100 N of external load. The results by a analysis for stress distribution of supporting bones of fixture were as below. The von Mises stress was concentrated on the upper side of supporting compact bone regardless of the diameters and lengths of fixture, and the efficiency result of stress reduction was increase of fixture's diameter than it's length. Therefore, it's effective to use wider fixture as possible to the conditions of supporting jaw bone.