• Title/Summary/Keyword: osseointegration.

Search Result 398, Processing Time 0.025 seconds

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

Dual Mobility Cup for Revision of Dislocation of a Hip Prosthesis in a Dog with Chronic Hip Dislocation

  • Jaemin Jeong;Haebeom Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.390-394
    • /
    • 2022
  • A 6-year-old, 36.5 kg castrated male Golden Retriever presented for revision surgery for left total hip replacement. The patient underwent removal of the cup and head implants due to unmanageable prosthetic hip dislocation, despite revision surgery. On physical examination, the dog showed persistent weight-bearing lameness after exercise of the left hindlimb with mild muscle atrophy. Radiographic examination revealed dorsolateral displacement of the femur with a remnant stem and bony proliferation around the cranial and caudal acetabulum rims. The surgical plan was to apply the dual mobility cup to increase the range of motion and jump distance to correct soft tissue elongation and laxity caused by a prolonged period of craniodorsal dislocation of the femur. The preparation of the acetabulum for cup fixation was performed with a 29-mm reamer, and the 29.5-mm outer shell was fixed with five 2.4-mm cortical screws. The head and medium neck of the dual-mobility system were placed on the cup, and the hip joint was reduced between the neck and stem. The dog exhibited slight weight bearing on a controlled leash walk the day after surgery. The patient was discharged 2 weeks postoperatively without any complications. Six months postoperatively, osseointegration and a well-positioned cup implant were observed, and the dog showed excellent limb function without hip dislocation until 18 months of phone call follow-up.

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.

Short-term, Multi-center Prospective Clinical Study of Short Implants Measuring Less Than 7mm

  • Kim, Young-Kyun;Yi, Yang-Jin;Kim, Su-Gwan;Cho, Yong-Seok;Yang, Choon-Mo;Liang, Po-Chin;Chen, Yu-Yal;I, Lee-Long;Sim, Christopher;Tan, Winston;Ser, Go Wee;Yue, Deng;Yi, Man;Ping, Gong
    • Journal of Korean Dental Science
    • /
    • v.3 no.1
    • /
    • pp.11-16
    • /
    • 2010
  • Objective : This prospective study sought to verify the stability of three types of short implants measuring 7mm or less. Materials and methods : Implants measuring 7mm or less were placed in patients at multicenter dental clinics in Korea, China, Taiwan, and Singapore. Initial stability, intraoperative and postoperative complications, crestal bone loss, and survival rate of the implant were prospectively evaluated. Results : The primary stability of a 6-mm implant was lower than that of a 7-mm implant. The marginal bone loss of short implants measuring less than 7mm was minimal. Complications such as wound dehiscence, implant mobility, and peri-implant mucositis developed, and these were associated with initial implant failure. The short-term survival rate of 6-mm implant was 93.7%, and that of 7-mm implant, 96.6%. Conclusion : Short implant for the mandible with insufficient height for the residual ridge can be selectively used. Poor primary stability and wound dehiscence can cause osseointegration failure and alveolar bone loss.

  • PDF

AUGMENTATION OF MAXILLARY ANTERIOR AREA USING DISTRACTION OSTEOGENESIS : CASE REPORT (골신장술을 이용한 상악 전치부 수복의 치험보고)

  • Kim, Hyun-Kyung;Lee, Hyun-Jin;Yeo, Duck-Sung;Lim, So-Yeon;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.242-246
    • /
    • 2006
  • Objective : This is to report the criteria of success of intraoral distraction osteogenesis for alveolar augmentation in the severely atrophied alveolar defects through clinical result of 2 cases. Subjects and Methods : Anterior segmental osteotomy was performed and alveolar distractors (Martin and Leibinger, Germany) were applied each in 2 patients with severely defected anterior maxillary area. The osteomized alveolar segments were distracted by 1mm a day after latency period. After the consolidation period implants were installed with removal of distractor. The implants were evaluated clinically and radiographically. Results : In Case I, the distracted bone was directed to the palatal side, and another augmentation treatment - block bone graft, guided bone regeneration - was needed. In Case II, the successful alveolar bone augmentation was achieved. Dental implant was placed on distracted alveolar bone, and showed good osseointegration and good function without any complication. Conclusion : Distraction osteogenesis can be a good choice for alveolar ridge augmentation of severely atrophied ridges. However, the anterior esthetic prosthetics relies on the control of the vector, the kind of distractor, the healing capacity of patient and the etiology of atrophy. Therefore another study of each category would be needed.

HISTOMORPHOMETRIC AND REMOVAL TORQUE VALUES COMPARISION OF ROUGH SURFACE TITANIUM IMPLANTS (임프란트 표면처리 방법에 따른 골유착의 조직계측학적 분석 및 제거회전력 비교 연구)

  • Lee, Sang-Chul;Song, Woo-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.396-405
    • /
    • 2001
  • Osseointegrated implants are used for the fixation of dental prosthesis with good long-term clinical results. In an attempt to improve the quantity and quality of the bone-implant interface, numerous implant modification have been used. Implants surface modifications have been used such as titanium-plasma sprayed, hydroxyapatite-coating, sandblasted, sandblasted and acid-etched, acid-etched. Rough surface implants have greater implant surface area and enhance the bone-implant interface and improve stabilization. The purpose of present study was to evaluate light microscopic and scanning microscopic examinations and removal torque value of newly developed calcium phosphate blast and acid-etched implant in the femur of rabbits. Titanium plasma sprayed(TPS) implant served as controls. After 12 weeks of healing of the femurs of 12 rabitts, the implant-containing segments of femur were removed on bloc and bone block including sections. Histologic examination and histomorphometric and removal torque values comparision were made for two implants. Obtained results are follows: 1. Newly developed calcium phosphate blasted and acid-etched implants were in close contact with bone under light microscopic examinations. 2. New implants showed mean bone-to implant contact 59.8%, whereas TPS implants showed mean bone-to implant contact 54.5% (statistically no difference p<0.05). 3. New implants showed mean bone density 56.7%, whereas TPS implants showed mean bone density 49.2% (statistically difference p<0.05). 4. New implants demonstrated mean removal torque values 40.5Ncm, whereas the mean removal torque values of TPS implants ranged 39.3Ncm. No statistical differences(p<0.05) were observed between two groups of implants nor was there any difference between the two implants at the clinical level.

  • PDF

Sinus augmentation using rhBMP-2-loaded synthetic bone substitute with simultaneous implant placement in rabbits

  • Joo, Myung-Jae;Cha, Jae-Kook;Lim, Hyun-Chang;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.86-95
    • /
    • 2017
  • Purpose: The aim of this study was to determine the effect of recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded synthetic bone substitute on implants that were simultaneously placed with sinus augmentation in rabbits. Methods: In this study, a circular access window was prepared in the maxillary sinus of rabbits (n=5) for a bone graft around an implant (${\varnothing}3{\times}6mm$) that was simultaneously placed anterior to the window. Synthetic bone substitute loaded with rhBMP-2 was placed on one side of the sinus to form the experimental group, and saline-soaked synthetic bone substitute was placed on the other side of the sinus to form the control group. After 4 weeks, sections were obtained for analysis by micro-computed tomography and histology. Results: Volumetric analysis showed that the median amount of newly formed bone was significantly greater in the BMP group than in the control group ($51.6mm^3$ and $46.6mm^3$, respectively; P=0.019). In the histometric analysis, the osseointegration height was also significantly greater in the BMP group at the medial surface of the implant (5.2 mm and 4.3 mm, respectively; P=0.037). Conclusions: In conclusion, an implant simultaneously placed with sinus augmentation using rhBMP-2-loaded synthetic bone substitute can be successfully osseointegrated, even when only a limited bone height is available during the early stage of healing.

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias

  • Park, Kyung-Soon;Al Awamleh, Abdel Ghani Ibrahim;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.73-78
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.

Laser therapy in peri-implantitis treatment: literature review (임플란트주위염 처치에서 레이저의 이용: 문헌고찰)

  • Lee, Kyung-Joong;Lee, Jong-Ho;Kum, Kee-Yeon;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.340-348
    • /
    • 2015
  • Peri-implantitis is the most common reason for a late failure and can occur even after years of successful osseointegration. The role of microbial plaque accumulation in the development of peri-implantitis has been well documented. On the other hand, the ideal method of implant surface decontamination to re-establish the health of peri-implant tissue remains to be determined. Removal of bacterial deposits is essential in the treatment of peri-implant infections, and various therapeutic approaches have been described in the literature, including mechanical debridement, disinfection with chemotherapeutic agents, and laser therapy. Recently, there has been a plenitude of scientific data regarding the use of laser irradiation to achieve titanium surface decontamination. Thus, research is focusing on lasers' potential use in the treatment of peri-implantitis. The aim of this literature review is to analyze and evaluate the efficacy of laser therapy for the treatment of peri-implantitis.