• Title/Summary/Keyword: osseointegration

Search Result 397, Processing Time 0.026 seconds

Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length (다양한 길이의 two-component 미니 임플란트의 응력분산에 대한 3차원적 유한요소분석)

  • Choi, Bohm;Lee, Dong-Ok;Mo, Sung-Seo;Kim, Seong-Hun;Park, Ki-Ho;Chung, Kyu-Rhim;Nelson, Gerald;Han, Seong-Ho
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.423-430
    • /
    • 2011
  • Objective: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEA). Methods: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. Results: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. Conclusions: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling.

The comparison between 2 wide implants and 3 regular implants in mandibular posterior area (하악 대구치부위의 고정성 보철물에서 2개의 장폭경과 3개의 표준 임프란트의 비교)

  • Yoo, Ho-Sun;So, Sung-Soo;Han, Dong-Hoo;Cho, Kyoo-Sung;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.577-588
    • /
    • 2002
  • Osseointegrated implants have been established as the standard treatment modality for full/partial edentulous patients since the 1960's, and the long term results for full edentulous patients have proven to be successful. Based on these results osseointegrated implants are now widely used for partial edentulous patients. There has been an increased interest towards the efficacy of wide implants, despite many reports mentioning the lower success rate of wide implants compared to regular implants. Recently, mandibular molar area defects are commonly restored using 2 wide implants, but it is not determined whether which treatment modality-3 regular implants or 2 wide implants-shows superior success rate. In this study, 2 wide implants and 3 regular implants used for the restoration of mandibular molar area are used to compare the survival rate of 1-4 years, and to analyze and compare the failure factors. The following conclusions could be drawn from this study. 1. Wide implants and regular implants showed 94.5% and 97,6% of survival rate respectively. After prosthodontic work, the survival rate was 100% and 98.1% for wide implants and regular implants respectively. 2. 5 failed implants have been removed. 2 wide implants and 1 regular implant have been removed due to failure of osseointegration. 1 wide implant was removed due to abscess formation caused by over-heating, and 1 regular implant was removed due to mechanical failure caused by over-loading within the first year of function. 3. No statistically significant difference was observed with respect to the amount of marginal bone loss of wide and regular implants.(P>0.05) In conclusion, restoration of the mandibular molar area using 3 regular implants was found to be a good treatment modality, and 2 wide implants could he considered a good treatment modality when success factors are taken into account.

THE EXPERIMENTAL STUDY ON BONE HEALING AROUND TITANIUM IMPLANTS PLACED IN IRRADIATED RAT'S TIBIAE (방사선 조사 백서 경골에 티타늄 임플랜트 매식후 골 치유에 관한 연구)

  • Kwak, Byung-Hak;Kim, Jong-Ryoul;Park, Bong-Soo;Shin, Sang-Hoon;Sung, Iel-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.6
    • /
    • pp.379-391
    • /
    • 2003
  • The present study was undertaken to evaluate bone regenerative capacity around titanium screw implants placed in irradiated rat's tibiae. At one week after single 15-Gy dose irradiation, miniaturized titanium screw implants were inserted into anterior aspect of the upper tibia of rats weighing 200-250g. Seventy rats were involved: 35 rats were control and 35 rats radiation group. The rats were killed at different intervals as 1, 2, 3, 4, 6, 8, 12 weeks after implantation for histologic observation, histomorphometric analysis and immunohistochemical study with fibronectin and CD34 antibody. 1. Histologically, various stages of bone maturation and ossification can be seen at 4 weeks and regenerated bone close to edges demonstrates more advanced calcification, and network of new bone are well formed at 12 weeks in non-irradiated group. In contrast, active bone formation with increased contact of newly formed bone to implant surface was noted at 4 weeks and a significant amount of new bone formation and bone-implant contact is oberved at 12 weeks in irradiated group. 2. Histomorphometrical analysis confirmed these histologic findings. A significant difference in implant-bone contact and bone density was measured between the control and radiation group. Mean MBD was 62.2% in control group and 27.5% in radiation group, mean MBIC was 86.6% in control group and 47.7% in radiation group, and mean TBIC was 87.3% in control group and 45.6% in radiation group at 12 weeks after implantation. 3. In immunohistochemical study with fibronectin and CD34, radiation reduced hematopoietic progenitor cells severely and disturbed differentiation of osteoblast in bone marrow. The results of this study revealed bone healing capacity around implant after radiation therapy was severely impaired and irradiation reduces the capacity for osseointegration of titanium implants. Many factors including radiation dose, period between radiation and implantation, bone quality, time elapse between first and second surgery, type of prosthetics and hyperbaric oxygen therapy must be considered carefully in postradiation implantation.

EFFECT OF CALCIUM AND VITAMIN D SUPPLEMENTATION ON BONE FORMATION AROUND TITANIUM IMPLANT (칼슘과 비타민 D 섭취가 티타늄 임플랜트 주위의 골 형성에 미치는 영향)

  • Park, Kwang-Il;Lee, Jae-Yeol;Hwang, Dae-Seok;Kim, Yong-Deok;Kim, Gyoo-Cheon;Shin, Sang-Hun;Kim, Uk-Kyu;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.131-138
    • /
    • 2007
  • The purpose of this study was to observe the effect of calcium and vitamin D to the titanium implant osseointegration in animal model. 32 rats, 10 weeks of age, were divided into two group: additional calcium and vitamin D supplementation group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm; pitch-height 0.4mm) were placed into tibia of 32 rats, 16 in the control group and 16 in the experimental group. The rats were sacrificed at different time interval(1, 2, 4, and 8 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with osteocalcin and osteopontin antibody. Histopathologically findings, newly formed bone was seen at 1 weeks and became lamellar bone at 2 weeks, and mature trabecullar bone was seen at 4 weeks experimental group. In control group, thickness of regenerated bone increased till 4 weeks gradually and trabecullar bone was seen at 8 weeks. By histomorphometric analysis, bone marrow density was increased significantly at 1 and 2 weeks in experimental group compared to control group. Osteocalcin immunoreactivity was strong at 1 week experimental group and reduced after 4 weeks gradually. But it was continuously weakly from 1 to 4 weeks in control group. Osteopontin immunoreactivity was very strong in newly formed bone from 2 to 8 weeks experimental group. And the amount of osteopontin expression was more abundant in experimental group. The results of this study suggest that calcium and vitamin D supplementation promotes bone healing around dental implants

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

EFFECT OF IMPLANT DESIGNS ON INSERTION TORQUE AND IMPLANT STABILITY QUOTIENT (ISQ) VALUE

  • Piao Chun-Mei;Heo Seong-Joo;Koak Jai-Young;Kim Seong-Kyun;Han Chong-Hyun;Fang Xian-Hao
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.325-332
    • /
    • 2006
  • Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant stability and osseiointegratation are considered highly desirable. Purpose. The purpose of this study was to evaluate the ISQ value and the insertion torque of the 3 different implant system, then to evaluate whether there was a correlation between ISQ value and insertion torque; and to determine whether implant design has an influence on either insertion torque or ISQ value. Material and method. The experiment was composed of 3 groups: depending on the implant fixture design. Group1 was Branemark type parallel implant in $3.75{\times}7mm$. Group2 was Oneplant type straight implant in $4.3{\times}8.5mm$. Group3 was Oneplant type tapered implant in $4.3{\times}8.5mm$. Depending on the density of the bone, 2 types of bone were used in this experiment. Type I bone represented for cortical bone, type II bone represented for cancellous bone. With the insertion of the implant in type I and type II bone, the insertion torque was measured, then the ISQ value was evaluated, and then the correlation between insertion torque and ISQ value was analyzed Result and conclusion. Within the limitations of this study, the following conclusions were drawn. 1. Within the 3 different implants, the insertion torque value and ISQ value were higher in type I bone, when compared with type II bone.(p<0.05) 2. In type I and type II bone, Oneplant type tapered implant has the highest value in insertion torque.(p<0.05) 3. In type I and type II bone, there was no difference in ISQ values among the 3 types of implant. (p>0.05) 4. Significant linear correlation was found in $Br{\aa}nemark$ type parallel implant: $3.75{\times}7mm$ in type II bone.

A STUDY ON THE HEAT GENERATION OF BONE DRILLING BURS ACCORDING TO IRRIGATION DURING IMPLANTATION OF DENIAL IMPLANT (치과 임플랜트 식립시 관주에 따른 골 천공 기구의 열 발생에 관한 연구)

  • Moon, Eun-Soo;Lim, Heun-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.433-453
    • /
    • 1999
  • There are a lot of elements affecting the success of implant prosthesis. The quality of surgical procedure is considered as one of the key factors. To avoid the excess heat generation is an important element of successful osseointegration and it can be achieved by using a gentle surgical technique with a sharp instrument in bone drilling. This study was performed to measure and analyze comparatively the heat transmitted to sur-rounding bone at a distance of 0.5mm from the periphery of the drill hole in each drilling stage. The results were as follows. In standard system, the temperature of surrounding bone tissue ranged from $29.2^{\circ}C\;to\;48.3^{\circ}C$ with irrigation and from $34.6^{\circ}C\;to\;84.3^{\circ}C$ without irrigation. And in wide system, the temperature of surrounding bone tissue ranged from $29.5^{\circ}C\;to\;52.5^{\circ}C$ with irrigation and from $34.8^{\circ}C\;to\;87.8^{\circ}C$ without irrigation. And the temperature ranges exceeded the threshold without irrigation, while showing less than the threshold by the cooling effect of irrigation. In comparing standard system with wide system, although there was no significant difference, ${\phi}4.3mm$ pilot and ${\phi}4.3mm$ twist drill of wide system showed high value and wide system showed slightly high elevation of temperature in all depth in fixture installation. In the finite element analysis, the calculated value by the Fourier's cooling law were applied to the bone drilling surface. And through analysis using different irrigation temperatures at $28^{\circ}C,\;15^{\circ}C\;and\;5^{\circ}C$, and according to the time. The result was that the cooling water at least below $15^{\circ}C$ was required to maintain the temperature of surrounding bone less than threshold in bone drilling, the cooling water below $5^{\circ}C$ was required to gain more sufficient cooling effect, and cooling over 5 seconds was needed after bone drilling for sufficient effect.

  • PDF

OCCLUSAL FORCE AND ORAL TACTILE SENSIBILITY MEASURED IN PARTIALLY EDENTULOUS PATIENTS WITH BR NEMARK IMPLANTS AND NATURAL TEETH: A CLINICAL STUDY (기능 노출 기간에 따른 골 유착성 임플란트의 촉각 감지도와 최대 교합력의 변화)

  • Jung, Bock-Young;Jeon, Young-Sik;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.23-41
    • /
    • 1999
  • During the previous several decades the osseointegrated implants have been considered as the most ideal therapy for the fully edentulous or partially edentulous patients. Although the research on the biocompatibility of osseointegration, the oral tactile function, and the histo-neurologic study had been performed, the change of the oral tactile sensibility and maximal occlusal force according to the postinsertion time of implant prostheses has not been studied. The purpose of this study was to compare the oral tactile sensibility and maximal occlusal force of implant pros-theses to natural teeth according to the specific postinsertion time intervals. The fifty seven patients treated with $Br{\aa}nemark$ implants during the recent seven years were involved in this study. The oral tactile sensibility and maximal occlusal force were measured according to the postinsertion time (${\leqq}6\;months,\;{\leqq}12\;{\leqq}\;18\;months\;{\leqq}\;24\;months,\;and\;{\geqq}20\;months$) 1. The passive tactile threshold of implants was higher than 6-7 times when comparing to natural teeth(P<0.05) 2. The absolute pressure threshold in horizontal and vertical direction for the passive tactile sensibility had decreased significantly in the post insertion time 13-18 months group and had increased significantly in the post insertion time over 25 months group (P<0.05) 3. 50% limit thickness and 100% absolute thickness for the active tactile sensibility had decreased significantly in the postinsertion time 7-12 months group ($AT_{50}:P<0.005,\;AT_{100}:P<0.05$) 4. The maximal occlusal force of the implants prostheses had decreased when comparing with natural teeth in the postinsertion time 1-6 months group(P<0.05) and after that there was no significant difference between the implant prostheses and natural teeth(P<0.05) 5. Maximal occlusal force according to the postinsertion time had increased significantly in the 13-18 months group (P<0.05) after that there was no significant difference. 6. There was positive correlation between age and oral tactile sensibility tested in horizontal and vertical direction ($P_{H:r}=0.39,\;P_{v:r}=0.41$) and there was no correlation between age and maximal occlusal force, age and active tactile sensibility 7. According to the results or the questionnaire, 76.6% of the patients were satisfied with the function and 96.7% of the patients were satisfied with the sensibility. In conclusion oral tactile sensibility and maximal occlusal force of implants have changed with the postinsertion time. Oral tactile function of implants was lower than that of the natural teeth, but for the maximal occlusal force there was no difference between implants and natural teeth.

  • PDF

Investigation of anodized titanium implants coated with triterpenoids extracted from black cohosh: an animal study

  • Park, In-Phill;Kang, Tae-Joo;Heo, Seong-Joo;Koak, Jai-Young;Kim, Ju-Han;Lee, Joo-Hee;Lee, Shin-Jae;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.14-21
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate bone response to anodized titanium implants coated with the extract of black cohosh, Asarum Sieboldii, and pharbitis semen. MATERIALS AND METHODS. Forty anodized titanium implants were prepared as follows: group 1 was for control; group 2 were implants soaked in a solution containing triterpenoids extracted from black cohosh for 24 hours; group 3 were implants soaked in a solution containing extracts of black cohosh and Asarum Sieboldii for 24 hours; group 4 were implants soaked in a solution containing extracts of pharbitis semen for 24 hours. The implants from these groups were randomly and surgically implanted into the tibiae of ten rabbits. After 1, 2, and 4 weeks of healing, the nondecalcified ground sections were subjected to histological observation, and the percentage of bone-to-implant contact (BIC%) was calculated. RESULTS. All groups exhibited good bone healing with the bone tissue in direct contact with the surface of the implant. Group 2 ($52.44{\pm}10.98$, $25.54{\pm}5.56$) showed a significantly greater BIC% compared to that of group 3 ($45.34{\pm}5.00$, $22.24{\pm}2.20$) with respect to the four consecutive threads and total length, respectively. The BIC% of group 1 ($25.22{\pm}6.00$) was significantly greater than that of group 3 ($22.24{\pm}2.20$) only for total length. CONCLUSION. This study did not show any remarkable effects of the extract of black coshosh and the other natural products on osseointegration of anodized titanium implants as coating agents. Further studies about the application method of the natural products on to the surface of implants are required.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.