• Title/Summary/Keyword: osseointegrated implant

Search Result 131, Processing Time 0.051 seconds

Occlusal concepts and considerations in implant supported prosthesis (임플란트 지지 보철물의 교합양식 및 고려사항)

  • Baek, Yeon-Wha;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • The Journal of the Korean dental association
    • /
    • v.58 no.8
    • /
    • pp.496-504
    • /
    • 2020
  • The osseointegrated implants react biomechanically in a different pattern to occlusal force, due to lack of the periodontal ligament unlike the natural teeth. The implants show markedly less movement and limited tactile sensitivity compared with the natural teeth. The implant occlusion concept aims to avoid overloading on the implants and to direct occlusal loads along the longitudinal axis of the implants, in order to compensate for the different biomechanics of the implants. Although many guidelines and theories on implant occlusion have been proposed, few have provided strong supportive evidence. Moreover, the outcome of treatment often quite successful in spite of different concepts of occlusion and there is an increasing tendency to doubt about the strict theoretical implant-specific occlusion concept. The purpose of this article is to review the previous reports about the concept of implant occlusion and discuss clinical occlusal considerations in implant rehabilitations.

  • PDF

Overcoming and Preventing Dental Implant Complications: Abutment Fracture Case Report

  • Kahm, Se Hoon;Kim, Chang-Hyun;Kim, Sung-Joon
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • The introduction of osseointegrated dental implants in dentistry brought about a new era in everyday dental practice. For the past 50 years, prosthetic restoration with implant-supported prosthesis has developed into a viable and predictable treatment option. Alongside the increasing use of dental implants is the occurrence of many complications during implant placement (surgery), in the mechanical or prosthetic problem, and in the biological aspect. In particular, abutment or screw fracture as one of the mechanical complications can put the dentist in a tight spot in a clinical situation. It is hard to remove the fractured abutment and screw to restore it properly. Therefore, it is very important that clinicians consider possible complications in advance and make an appropriate treatment plan. We discuss cases of abutment fracture and mechanical/prosthetic complications together with the causes and solutions.

A THREE DIMEMSIONAL PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTING BONE TISSUE ACCORDING TO DESIGN OF ATTACHMENTS USED FOR MANDIBULAR OVERDENTURE USING TWO OSSEOINTEGRATED IMPLANSTS (두개의 골유착성 임프란트를 이용한 하악 OVERDENTURE에서 ATTACHMENT 설계에 따른 임프란트 지지조직의 삼차원적 광탄성 응력분석)

  • Shin, Kyoo-Hag;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.31-69
    • /
    • 1996
  • The purpose of this investigation was to analyze stress distribution in implant supporting tissue according to different types of attachments such as combination bar attachment, Hader bar attachment, O-Ring attachment and Dal-Ro attachment that are used in mandibular overdenture by using two osseointegrated implants, to study the influence that POM IMC used in bar type attachment has in implant supporting tissue and compare the preceding analyses to find out an effective stress distribution method. Three dimensional photoelastic method was used to obtain the following results. (A) Analysis of stress distribution according to attachment type 1. Under vertical load condition, compressive stress was seen at implant supporting area of working side on all the photoelastic models but in Hader bar attachment tensional stress was seen at distal upper area of implant supporting area. Relatively Hader bar and O-Ring attachment showed even stress distribution pattern. 2. Under vertical load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models. 3. Under $25^{\circ}$ lateral load condition, general compressive stress was seen at working side implant supporting area in most of the models, especially at distal upper supporting area higher compressive stress concentration was seen in combination bar attachment and tensional stress concentration, in Hader bar attachment. 4. Under $25^{\circ}$ lateral load condition, compressive stress at implant apex area and tensional stress at implant lateral supporting area were seen at nonworking side of all models, except O-Ring model which showed compressive stress only. (B) Influence of POM IMC to stress distribution in bar type attachment 5. Under vertical load condition, better stress distribution pattern was seen at working side of combination bar and Hader bar attachment model using POM IMC. 6. Under vertical load condition, stress value was increased at nonworking side of combination bar attachment model using POM IMC and tendency of increasing compression was seen at nonworking side of Hader bar attachment model using POM IMC. 7. Under $25^{\circ}$ lateral load condition, better stress distribution pattern was seen at working side of combination bar attachment model using POM IMC but tendency of increasing stress was seen on working side of Hader bar attachment model using POM IMC. 8. Under $25^{\circ}$ lateral load condition, stress reduction was seen at nonworking side of combination bar attachment model using POM IMC but tendency of increasing stress was seen at nonworking side of Hader bar attachment model using POM IMC.

  • PDF

Analysis of Implant Prosthesis using 2-Dimensional Finite Element Method (2차원유한요소분석을 이용한 임플란트 보철물의 적합도 분석)

  • Kwon, Ho-Beom;Park, Chan-Je;Lee, Seok-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.341-348
    • /
    • 2006
  • Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

Analysis of Implant Prosthesis Using 2-Dimensional Finite Element Method (2차원 유한요소분석을 이용한 임플란트 보철물의 적합도 분석)

  • Kwon, Ho-Beom;Park, Chan-Je;Lee, Seok-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.3
    • /
    • pp.251-260
    • /
    • 2006
  • Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

The impact of the alveolar bone sites on early implant failure: a systematic review with meta-analysis

  • Fouda, Atef Abdel Hameed
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.3
    • /
    • pp.162-173
    • /
    • 2020
  • Dental implants are the first option for replacement of missing teeth. Failure usually involves additional cost and procedures. As a result, the physician should limit the risk factors associated with implant failures. Implant site is one of many factors that can influence the success or failure of dental implants. The association between early implant failure (EIF) and implant site has yet to be documented. This review aims to estimate the impact of insertion site on the percentage of EIFs. An electronic and manual search of studies that reported early failure of dental implants based on collection site. A total of 21 studies were included in the review and examined for the association between EIF and alveolar site. Subgroup analysis, including a comparison between implants inserted in four alveolar ridge regions of both jaws was performed. The early failure rate was higher for maxillary implants (3.14%) compared to mandibular implants (1.96%). Applying a random effect, risk ratio (RR), and confidence interval (CI) of 95% revealed higher failure in the maxilla compared to the mandible (RR 1.41; 95% CI [1.19, 1.67]; P<0.0001; I2=58%). The anterior maxilla is more critical for early implant loss than other alveolar bone sites. Implants in the anterior mandible exhibited the best success rate compared of the sites.

Hybrid Prosthesis Supported by Osseointegrated Implants in Maxilla (골유착성 임프란트에 의해 지지되는 새로운 설계의 Hybrid Prosthesis)

  • Lee, J.S.;Shin, S.W.
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.46-59
    • /
    • 1999
  • A fixed bridge is preferred as a prosthetic option supported by oral implants. However, it is very difficult to re tore edentulous maxilla with fixed prosthesis in cases with improper position and angulation of fixtures, abnormal jaw relation, and need for proper lip support. Six Br${\aa}$nemark implants were installed in edentulous maxilla opposing mandible with natural dentition. A removable hybrid prosthesis attached to a bar milled by 6 degrees was therefore designed to overcome such disadvantages of fixed prosthesis. Lateral stabilization of removable prosthesis was obtained by framework closely fitting the milled bar. Support for the prosthesis was ensured by three elevated areas on the bar. Two precision attachments(CEKA REVAX) provided appropriate direct and indirect retention without influencing support. A clinical and laboratory procedure was presented.

  • PDF

A COMPARATIVE STUDY ON SUBGINGIVAL MICROBIAL COMPOSITION BETWEEN NATURAL TEETH AND OSSEOINTEGRATED IMPLANTS (골유착성 임플랜트와 자연치의 치은연하 세균조성에 대한 비교연구)

  • Lim Yong-Sik;Kim Yung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.411-422
    • /
    • 1993
  • Osseointegrated dental implants are now an accepted part of the prosthetic treatment of fully and partially edentulous patients. Clinical studies have shown that osseointegrated dental implants may successfully be used as abutments for prosthetic rehabilitations, and that the supporting tissue can be kept in a stable and healthy clinical state for prolonged periods of time. The purpose of this study was to look for differences in the distribution in the bacterial morphotypes around natural teeth and osseointegrated dental implants. The subgingival plaque around natural teeth and implants was analysed by means of differential phase-contrast microscopy. In addition, clinical indices used to analyse natural teeth condition were used to compare the condition of natural teeth and implants. The results were as follows : 1. In implants of partially edentulous patients, the plaque index, sulcus bleeding index(P<0.05), pocket depth(P<0.01) were greater than natural teeth. 2. Gingival crevicular fluid volume was not significantly different between natural teeth and implants. 3. In implants of fully edentulous patients, the plaque index was greater than natural teeth(P<0.01) and implants of partially edentulous patients(P<0.05), but sulcus bleeding index was not significantly different. 4. In partially edentulous patient, coccoid cell proportion was greater in implants than natural teeth (P<0.05). 5. In implants of fully edentulous patients, coccid cell proportion was even greater than implants of partially edentulous patients(P<0.05) and natural teeth(P<0.01). 6. Among three groups, the proportions of non-motile rods, motile rods, spirochetes and others were not significantly different. 7. The proportion of motile bacteria was not significantly different among three group.

  • PDF

Application of dental implant for orthodontic anchorage (보철 수복용 임플란트의 교정치료를 위한 고정원의 활용)

  • Kang, Hyo-Jin;Park, Eun-Jin;Kim, Sun-Jong;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.6
    • /
    • pp.404-413
    • /
    • 2016
  • Currently, dental implants have become predictable and reliable adjuncts for oral rehabilitation. Osseointegrated implants can be used to provide rigid orthodontic anchorage and have advantages compared conventional orthodontic anchorage especially when there were edentulous areas and implants were scheduled as a treatment plan. Orthodontic force doesn't cause the bone loss of osseointegrated implants. Implant materials, surgical protocols and healing time before loading follow the conventional treatment protocol. Because the implants, once installed, can't change the location, meticulous treatment planning should be preceded. Further investigations are needed to standardize the treatment protocol.

  • PDF

국산 Avana implant의 임상결과에 관한 연구

  • Lee, Jae-Bong;Wang, Yeong-Su;Sin, Gwang-Ho;Hwang, Byeong-Nam
    • The Journal of the Korean dental association
    • /
    • v.38 no.6 s.373
    • /
    • pp.558-566
    • /
    • 2000
  • Osseointegrated dental implants have now become and accepted form of treatment for patients with a fully or partially missing dentition. The purpose of this study was to evaluate the performance of AVANA implant-Korea. A total of 323 AVANA implants were placed at 9 centers in the edentulous and partially edentulous jaws of 88 consecutive patients ranging in age form 18 to 79 years. So we get the clinical results. 1. Both patients (94.4%) & doctors (94%) were satisfied with the results, in patient's aspect 'most satisfaction' case were more common(52%) 2. The length of fixture which was frequently used was 13mm (168/319,44.5%) followed by 15mm and 10mm, and 3.75mm width implant (239/319,74.9%) was the most popularly used. 3. Mandibutar posterior was the most common installation site (140/317.43%) 4. A mean implant survival rate was 96.2%. That showed little difference which reported other paper. Cause of failure consisted of inflammation $ infection-36%, fall of osseointegration-18%, paln during masticatory function-9%. improper prosthetic function $ procedure-9%. 5. The most popularly used types of abutment was the UCLA abutment(168/305,55.5%)

  • PDF