• Title/Summary/Keyword: orthodontic materials

Search Result 183, Processing Time 0.026 seconds

Observation of trabecular changes of the mandible after orthognathic surgery using fractal analysis

  • Kang, Hyeon-Ju;Jeong, Song-Wha;Jo, Bong-Hye;Kim, Yong-Deok;Kim, Seong-Sik
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.2
    • /
    • pp.96-100
    • /
    • 2012
  • Objectives: This study sought to evaluate trabecular changes in the mandible using fractal analysis and to explain the transient osteopenia related to rapid orthodontic tooth movement after orthognathic surgery. Materials and Methods: Panoramic radiographs were taken of 26 patients who underwent bilateral sagittal split ramus osteotomy. Radiographs taken before the surgery and 1 month after surgery were overlapped, and $40{\times}40$ pixel square regions of interest were selected near the mandibular canines and 1st molars. After the image processing procedure, the fractal dimension was calculated using the box-counting method. Results: Fractal dimension after orthognathic surgery decreased in a statistically significant manner (P<0.05). The change in fractal dimension on the canine side had greater statistical significance as compared to that seen on the 1st molar side. Conclusion: This study found that bone density decreases after orthognathic surgery due to transient osteopenia related to the regional acceleratory phenomenon. This result can provide a guide to evaluating orthodontic tooth movement after orthognathic surgery.

Tooth Movement in Demineralized Area by Etchant in Rabbits

  • Choi, Bohm;Kim, Tae-Gun;Han, Seung-Hee;Park, Yoon-Hee;Lee, Won
    • Journal of Korean Dental Science
    • /
    • v.5 no.1
    • /
    • pp.37-44
    • /
    • 2012
  • Purpose: Among the facilitation of tooth movement in adult orthodontic treatment methods, surgical approaches are gaining popularity but complications following mechanical bone reduction are a problem. In this study, tooth movement was observed after alveolar bone was chemically demineralized to verify whether tooth movement had been facilitated. Materials and Methods: Twelve rabbits were used. In the experimental group, the alveolar bone of the left first molar area was exposed and demineralized. Thirty seven percents phosphoric acid was applied for 5 minutes for demineralization. The opposite first molar area was used as control. Two teeth were pulled with 200 g force and 4 rabbits each were sacrificed at 3, 7, and 14 days after the force was applied. Histologic examination was done with hematoxylin and eosin and tartrate-resistant acid phosphatase staining. Result: The histologic examination results revealed more bone resorption in the demineralized area. As time passed, the number of osteoclasts increased in the compressed area. The amount of tooth movement was larger in the experimental group compared to the control group but the difference was not statistically significant. Conclusion: The demineralization with etchant resulted in limited bone resorption, more tooth movement and less damage of the cementum after applied orthodontic force.

Common conditions associated with mandibular canal widening: A literature review

  • Mortazavi, Hamed;Baharvand, Maryam;Safi, Yaser;Dalaie, Kazem;Behnaz, Mohammad;Safari, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.87-95
    • /
    • 2019
  • Purpose: The aim of this study was to review the common conditions associated with mandibular canal widening. Materials and Methods: General search engines and specialized databases including Google Scholar, PubMed, PubMed Central, Science Direct, and Scopus were used to find relevant studies by using the following keywords: "mandibular canal," "alveolar canal," "inferior alveolar nerve canal," "inferior dental canal," "inferior mandibular canal," "widening," "enlargement," "distension," "expansion," and "dilation." Results: In total, 130 articles were found, of which 80 were broadly relevant to the topic. We ultimately included 38 articles that were closely related to the topic of interest. When the data were compiled, the following 7 lesions were found to have a relationship with mandibular canal widening: non-Hodgkin lymphoma, osteosarcoma, schwannoma, neurofibroma, vascular malformation/hemangioma, multiple endocrine neoplasia syndromes, and perineural spreading or invasion. Conclusion: When clinicians encounter a lesion associated with mandibular canal widening, they should immediately consider these entities in the differential diagnosis. Doing so will help dentists make more accurate diagnoses and develop better treatment plans based on patients' radiographs.

A study on the shear bond strengths of orthodontic brackets according to surface treatments and polymerizing techniques. (도재표면의 처리방법과 접착제의 중합방식에 따른 교정용 브라켓의 전단강도의 연구)

  • Kim, Young-Joo;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.445-456
    • /
    • 1999
  • As a result of increased education and communication, the field of orthodontics has recently been expanded to include a greater number of adult treatment procedures. With this increased demand for adult orthodontic treatment, a problem that frequently arises is the placement of appliances on teeth restored with porcelain. But conventional acid-etching is ineffective in the preparation of porcelain surface for mechanical retention of orthodontic attachments. Also, it is possible to damage on porcelain. The purpose of this study was to evaluate the effect of composite bonding materials and the porcelain surface treatment methods on shear bond strength, and to observe the porcelain fracture rates. To accomplish this purpose, this study was carried out with feldsphatic porcelain, Ceram II. Porcelain surface treatment methods were divided into intact glazed porcelain which had not treatment and surface roughening. Surface roughening by etching with Hydroluoric acid(HF), sandblasting with Microetcher II and compound treatment with etching and sandblasting. Bonding materials were Ortho-two and Transbond. All porcelain specimens were applicated with porcelain primer. 1. In comparision according to porcelain surface treatment, surface roughening groups by HF etching and sandblasting had higher shear bond than intact group. No significant difference was found in Transbond group. 2. Ortho-two group had the higher shear bond strength than that of Transbond group in B:.u etching and sandblasting. 3. E(Transbond. Intact)group had the lowest shear bond strength in all experimental group. The bond strength was higher than clinically successful bond strength. 4. Non-treated group had very higher porcelain rates than treated group. 5. This study indicates that porcelain surface-roughening may not be necessary to attachment of orthodontic brackets to porcelain surfaces.

  • PDF

REHABILITATION OF MISSING ANTERIOR TOOTH USING FIBER-REINFORCED COMPOSITE RESIN (Fiber-reinforced composite resin을 이용한 전치부 결손 수복)

  • Park, Heon-Jeong;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.1
    • /
    • pp.62-68
    • /
    • 1999
  • One of the many dilemmas that the clinical restorative dentist must face is treating young adolescent patient who prematurely loses his permanent teeth. Temporary prosthetic replacement can be achieved with removable denture, orthodontic band-wire fixed denture, adhesion bridge, composite resin splint with reinforcing material until the patients go through growth and development. But, all of these have limitations. Advances in restorative materials and reinforcement materials have made possible new techniques which are as much esthetic, conservative and more economic and stronger than adhesion brides. Two cases are being presented where gas-plasma treated, woven polyethylene fabric to reinforce composite resin was used to fabricate a temporary prosthetic restoration to replace a missing maxillary central incisor. This relatively noninvasive and basically reversible procedure allows the patient to decide the final restoration as he or she goes thorough maturation of the hard and soft tissues.

  • PDF

Analysis of Mechanical Properties of Polymer Material for Clear Aligner using Uniaxial Tensile Test (일축인장시험을 통한 투명교정장치용 고분자 소재의 역학적 특성 분석)

  • Jeong, Ji-Young;Je, Tae-Jin;Jeon, Eun-chae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.64-69
    • /
    • 2018
  • Clear aligners are popular in the field of dental orthodontic treatment because they offer a discreet alternative to braces due to their use of transparent materials. They are formed from flat transparent polymer materials by hot pressed molding. It is necessary to know the mechanical properties of the polymer materials to be able to form the exact shapes of the clear aligners. However, this information is not publicly available. In this study, we present a method to reliably measure the mechanical properties of clear aligner polymer materials and analyze the factors effecting these mechanical properties. First, we surveyed standards related to the mechanical properties of polymer materials to obtain reliable data. Consequently, ISO 527 was selected for use in this study because of the size and thickness of the flat transparent polymer material. The uniaxial tensile tester was constructed and it was verified whether displacement of a crosshead could be regarded as a displacement of gauge-length by optical analysis. Uniaxial tensile tests of three thicknesses from three different companies were performed and each engineering stress-strain curve was measured. Tensile strengths and elastic moduli were obtained by analysis of the stress-strain curves. The tensile strength and elastic modulus of ISO 527 was found to be approximately 50MPa and 2.3GPa, respectively. Both values showed material and thickness dependency.

A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions (교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구)

  • Lee, Jin-Woo;Cha, Kyung-Suk;Han, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.271-281
    • /
    • 2001
  • The Purpose of this study was fourfold - to evaluate the general laws of friction applied to orthodontic conditions, to compare archwire materials under these controlled conditions, to compare ligation method, and to measure the effect of the artificial saliva on friction with these materials Three wire alloys (Cobalt-chromium, Nickel-titanium, Beta-titanium) in two size wires (.016" , .016" ${\times}$.022" ) were examined respect to the bracket (.018" ${\times}$.025" standard), and two ligature material (stainless steel, elastomeric) in dry and wet conditions The results were as follows, 1. The order of frictional force against alloy materials was Co-Cr (lowest), Ni-Ti, and ${\beta}$-Ti(highest) - with the exception of elastomeric ligation under wet conditions. 2. S.S. ligation gave rise to significantly greater friction than elastomeric ligation did. 3. Testing in the presence of saliva, rather than in dry conditions, decreased the frictional force for S.S. ligation with .016" Co-Cr, Ni-Ti, ${\beta}$-Ti. but, increased the frictional force for S.S. ligation with .016" ${\times}$ .022" Co-Cr, Ni-Ti, ${\beta}$-Ti. 4. .016" ${\times}$.022 " wire generated more friction than .016" wire.

  • PDF

AN EXPERIMENTAL STUDY ON CHANGES OF ORTHODONTIC WIRES AFTER ELECTROPOLISHING (전해연마후 교정선의 변화에 관한 실험적 연구)

  • Lee, Jai-Chul;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.22 no.4 s.39
    • /
    • pp.823-836
    • /
    • 1992
  • Guiding a tooth along an arch wire results in a counteracting frictional force among arch wires, bracket and ligature. This frictional forces should be eliminated or minimized when orthodontic teeth movement is being planned. The purpose of this study was to evaluate the changes of width, cross-sectional forms and surface morphologies of stainless steel wire and $Elgiloy^{\circledR}$ wire after electropolising. Experimental variables included in this experiment were arch wire materials, current, electrolyte temperature and polishing time. Wire widths were measured by micrometer and cross-sectional forms and surface morphologies were examined with optical microscope and scanning electron microcope. The results were as follows: 1. The mean and standard deviation of widths of stainless steel wire and $Elgiloy^{\circledR}$ wire varying polishing time with condition of $249A/dm^2$ and $20^{\circ}C,\;249A/dm^2$ and, $332A/dm^2$ and $20^{\circ}C$ and $332A/dm^2$ and $250^{\circ}C$ were obtained. 2. With increasing polishing time, the widths of stainless steel wire and $Elgiloy^{\circledR}$ wire became decreased proportionally 3. The changes of widths of stainless steel wire and $Elgiloy^{\circledR}$ wire were statistically insignificant between $20^{\circ}C$ group and $25^{\circ}C$ group, but significant between $249A/dm^2$ group and $332A/dm^2$ group. 4 The cross-sectional forms of wire after electropolishing were not changed in stainless steel wire, and while it were changed to rounded corners in $Elgiloy^{\circledR}$ wire. 5. The surface morphologies of wire after electropolishing were scratch-absent and more smoothened both in stainless steel wire and $Elgiloy^{\circledR}$ wire.

  • PDF

The effect of fluoride-containing oral rinses on the corrosion resistance of titanium alloy (Ti-6Al-4V)

  • Huang, Gui-Yue;Jiang, Heng Bo;Cha, Jung-Yul;Kim, Kwang-Mahn;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.306-312
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effect of commercially available fluoride-containing oral rinses on the corrosion behavior of titanium alloys, which are the main components of orthodontic miniscrews. Methods: Four commercially available oral rinses (solution A, pH 4.46/260 ppm fluoride; solution B, pH 4.41/178 ppm fluoride; solution C, pH 6.30/117 ppm fluoride; and solution D, pH 4.17/3.92 ppm fluoride) were tested on titanium alloy (Ti-6Al-4V) circular plates, and saline was used as the control. The open-circuit potential and potentiodynamic polarization of these materials were measured. Thereafter, all samples were evaluated under a field-emission scanning electron microscope. Results: Among the tested oral rinses, except solution D, the more the fluoride content was, the greater was the corrosion potential downtrend; the corrosion resistance of the titanium alloy sample was also lowered significantly (p < 0.05). Field-emission scanning electron microscopic analysis of the surface morphology of the titanium alloy samples revealed that all samples had some defects, crevices, or pitting after exposure to the oral rinses than before treatment. In particular, the samples in solution A showed the most changes. Conclusions: Commercially available oral rinses having a high fluoride concentration and a low pH may reduce the corrosion resistance of titanium alloys used in dental appliances such as orthodontic titanium miniscrews and brackets.

Alveolar bone thickness and fenestration of incisors in untreated Korean patients with skeletal class III malocclusion: A retrospective 3-dimensional cone-beam computed tomography study

  • Oh, Song Hee;Nahm, Kyung-Yen;Kim, Seong-Hun;Nelson, Gerald
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate vertical bone loss and alveolar bone thickness in the maxillary and mandibular incisors of patients with skeletal class III malocclusion. This study also aimed to evaluate the periodontal condition of class III malocclusion patients who had not undergone orthodontic treatment. Materials and Methods: The sample included cone-beam computed tomography scans of 24 Korean subjects (3 male and 21 female). Alveolar bone thickness (ABT), alveolar bone area (ABA), alveolar bone loss (ABL), and fenestration of the maxillary and mandibular incisors were measured using 3-dimensional imaging software. Results: All incisors displayed an ABT of less than 1.0 mm from the labial surface to root level 7 (70% of the root length). A statistically significant difference was observed between the mandibular labial and lingual ABAs and between the maxillary labial and mandibular labial ABAs. The lingual ABA of the mandibular lateral incisors was larger than that of the mandibular central incisors. ABL was severe on the labial surface. A statistically significant difference was observed between the maxillary and mandibular labial ABL values(21.8% and 34.4%, respectively). Mandibular lingual ABL (27.6%) was significantly more severe than maxillary lingual ABL (18.3%) (P<0.05). Eighty-two fenestrations were found on the labial surfaces of the incisors, while only 2 fenestrations were observed on the lingual surfaces. Fenestrations were most commonly observed at root level 6. Conclusion: Careful evaluation is needed before orthodontic treatment to avoid iatrogenic damage of periodontal support when treating patients with class III malocclusion.