• 제목/요약/키워드: orthodontic materials

검색결과 183건 처리시간 0.024초

투명 장치의 열가소성 재료의 올바른 이해 (Physical properties of thermoplastic material for clear aligners)

  • 차정열
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.542-550
    • /
    • 2016
  • Recent technological advance have greatly expanded the application of invisible orthodontic treatment using clear thermoplastic materials. However, the final outcomes using clear aligner system do not achieve the level of final goal frequently, which results in case refinement, midcourse correction, or fixed orthodontic treatment. Therefore, mechanical properties of thermoplastic materials should be considered to improve the quality of outcomes. The purposes of this special article were to evaluate the force and stress depending on the materials, deflection and thickness of thermoplastic materials and to evaluate the mechanical properties of thermoplastic materials after repeated loading. Thickness and amount of deflection rather than products and materials showed the largest effect on force and stress. In all products, at least 159 gf of force was required for more than 1.0 mm deflection or when materials with 1.0 mm thickness were deflected. Orthodontic forces delivered by thermoplastic materials depend on the materials, thickness, amount of activation, and intra-oral condition. Proper thickness of thermoplastic materials and deflection level of tooth movement should be decided for the efficient and physiologic tooth movement.

  • PDF

TiN 및 ZrN 코팅된 교정용 브라켓의 부식특성 (Corrosion Characteristics of TiN and ZrN Coated Orthodontic Brackets)

  • 김원기;김도영;최한철
    • 한국표면공학회지
    • /
    • 제41권4호
    • /
    • pp.163-168
    • /
    • 2008
  • The dental orthodontic bracket requires good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. The objective of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance of orthodontic brackets using various electrochemical methods. Brackets manufactured by Ormco Co. were used, respectively, for experiment. Ion plating was carried out for coatings of bracket using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive Xray spectroscopy(EDS) and electrochemical tester. The corrosion potential of the TiN and ZrN coated bracket was comparatively high. The current density of TiN and ZrN coated bracket was smaller than that of non-coated bracket in 0.9% NaCl solution. Pit nucleated at angle of bracket slot.

Antibacterial and remineralization effects of orthodontic bonding agents containing bioactive glass

  • Kim, You-Min;Kim, Dong-Hyun;Song, Chang Weon;Yoon, Seog-Young;Kim, Se-Yeon;Na, Hee Sam;Chung, Jin;Kim, Yong-Il;Kwon, Yong Hoon
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.163-171
    • /
    • 2018
  • Objective: The aim of this study was to evaluate the mechanical and biological properties of orthodontic bonding agents containing silver- or zinc-doped bioactive glass (BAG) and determine the antibacterial and remineralization effects of these agents. Methods: BAG was synthesized using the alkali-mediated solgel method. Orthodontic bonding agents containing BAG were prepared by mixing BAG with flowable resin. $Transbond^{TM}$ XT (TXT) and $Charmfil^{TM}$ Flow (CF) were used as controls. Ion release, cytotoxicity, antibacterial properties, the shear bond strength, and the adhesive remnant index were evaluated. To assess the remineralization properties of BAG, micro-computed tomography was performed after pH cycling. Results: The BAG-containing bonding agents showed no noticeable cytotoxicity and suppressed bacterial growth. When these bonding agents were used, demineralization after pH cycling began approximately 200 to $300{\mu}m$ away from the bracket. On the other hand, when CF and TXT were used, all surfaces that were not covered by the adhesive were demineralized after pH cycling. Conclusions: Our findings suggest that orthodontic bonding agents containing silver- or zinc-doped BAG have stronger antibacterial and remineralization effects compared with conventional orthodontic adhesives; thus, they are suitable for use in orthodontic practice.

다양한 교정용 브라켓 원재료에 부착하는 mutans streptococci 양의 비교분석 (Quantitative analysis of mutans streptococci adhesion to various orthodontic bracket materials in vivo)

  • 유진경;안석준;이신재;장영일
    • 대한치과교정학회지
    • /
    • 제39권2호
    • /
    • pp.105-111
    • /
    • 2009
  • 법랑질 탈회는 교정 치료 중에 발생하는 대표적인 부작용으로서 특히 교정용 브라켓에 대한 세균 부착이 그 원인이 될 수 있다. 본 연구의 목적은 서로 다른 표면 특성을 가진 세 종류의 브라켓을 구강 내 장착했을 때 각 재료의 표면에 대한 mutans streptococci 부착 정도를 측정하여 브라켓 재료에 따른 법랑질 탈회 및 치아 우식 발생 가능성을 분석하는 것이었다. 상하악 및 치아 부위별 mutans streptococci 부착 정도의 차이를 배제하고 브라켓 원재료에 따른 차이만을 검출하기 위하여 균형완전블록 실험계획을 설계하였다. 피실험자인 30세 여성의 구강 내에 장착할 수 있는 tooth positioner 형태로 3세트의 플라스틱 맞춤 트레이를 제작하였으며, 이 트레이에 직육면체의 형태($4{\times}3{\times}2\;mm$)로 제작한 stainless steel, monocrystalline sapphire, polycrystalline alumina 조각을 세트마다 서로 다른 순서로 전치부와 구치부 순면에 부착하였다 이렇게 제작된 3종류의 실험장치를 12시간 동안 피 실험자의 구강 내에 장착한 후, 각 브라켓 재료 표면에 형성된 치태를 채취하여 bacitracin이 포함된 mitis salivarius배지에서 48시간 배양 후 colony counting을 통해 그 표면에 부착된 mutans streptococci 양을 비교하였다. 이와 같은 방법으로 3세트의 실험장치에 대해서 각각 5회씩 총 15회의 실험을 시행하였다. 그 결과 상하악 및 치아 부위별 및 브라켓 재료별 세균 부착 정도는 모두 유의한 차이를 보이지 않았다. 결론적으로 본 연구의 결과 in vivo condition에서 브라켓 재료의 차이는 mutans streptococci 부착에 영향을 미치지 못하는 것으로 보였다.

Intermittent Administration of Parathyroid Hormone for Orthodontic Tooth Movement in Mongrel Dogs: Preliminary Study

  • Won-Ho Kim;Bo Ram Lee;Hey-Yun Kim;Minji Kim;Jin-Woo Kim
    • Journal of Korean Dental Science
    • /
    • 제16권2호
    • /
    • pp.182-191
    • /
    • 2023
  • Purpose: This study investigated the orthodontic tooth movement after weekly parathyroid hormone (PTH) injection in mongrel dogs and analyzes bone formation activity on the tension and pressure sides of the tooth movement in mongrel dogs. Materials and Methods: Three mongrel dogs were used in this study. The first premolar was extracted and orthodontic force using 150 g of closed coil springs between the canine and second premolar was applied. The low-dose PTH group (PTH_1) and high-dose PTH group (PTH_2) received weekly injections of 1.61 ㎍/kg and 3.23 ㎍/kg of PTH, respectively. The control group received weekly injections of 1 ml of saline. Clinical, histomorphometric analysis were carried out. Result: The orthodontic tooth movement was greatest in the PTH_2 group and the lowest in the control group. Fluorescence staining images showed higher bone remodeling on the tension side of the tooth movement in the PTH_1 and PTH_2 groups. PTH_2 group showed a thicker labeling band than the PTH_1 group. PTH_2 group showed the highest mineral apposition rate and bone formation rate, followed by the PTH_1 group and the control group. Conclusion: Weekly intermittent PTH injection, especially in the short-term and at higher doses with orthodontic force, successfully increased orthodontic tooth movement and bone remodeling in mongrel dogs.

Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

  • Abdala-Junior, Reinaldo;No-Cortes, Juliana;Arita, Emiko Saito;Ackerman, Jerome L.;da Silva, Renan Lucio Berbel;Kim, Jun Ho;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.413-419
    • /
    • 2021
  • Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

투명교정장치의 임상적 한계와 그 해결 (Clinical limitations and its solutions of the clear overlay appliance treatment)

  • 배기선
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.563-574
    • /
    • 2016
  • A clear overlay appliance is a type of a removable appliance made from transparent thermoplastic plastic film that covers the entire dentition to move the teeth. It is one of the most favored orthodontic methods opted for by adult patients; this treatment is esthetic, does not cause discomfort and allows oral hygiene to be easily managed when compared to other conventional fixed treatment methods. However, the use of clear overlay appliances, such as invisalign or clear aligner, is associated with various clinical challenges. In particular, the appliances require longer treatment periods compared to fixed treatment, and due to the structural characteristics of the appliances, it is difficult to make proper posterior occlusion and certain type of tooth movement, including extrusion, rotation and tip. Thus, the clear overlay appliances are regarded as supplementary appliances by most orthodontists and have been used for simple orthodontic treatments, such as partial anterior alignments or orthodontic relapse cases. Owing to the remarkable advancement in the field of 3D digital technology over a period of 15 years, the accuracy and convenience of modern clear overlay appliances have continuously improved. Moreover, orthodontic outcomes have also been greatly improved by the introduction of new materials and successful application of various biomechanical methods from conventional orthodontic treatments in the design of clear overlay appliances. This study investigates the clinical limitations that should be considered during the application of clear overlay appliances and also examines the efforts and methods used to overcome these challenges.

  • PDF

3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가 (Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning)

  • 정기정;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

교정용 와이어의 표면특성에 미치는 TiN 및 ZrN 코팅영향 (Effects of TiN and ZrN Coating on Surface Characteristics of Orthodontic Wire)

  • 김원기;김도영;최한철
    • 한국표면공학회지
    • /
    • 제41권4호
    • /
    • pp.147-155
    • /
    • 2008
  • The dental orthodontic wire provides a good combination of strength, corrosion resistance and moderate cost. The purpose of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance and physical property of orthodontic wire using various instruments. Wires(round type and rectangular type) were used, respectively, for experiment. Ion plating was carried out for wire using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive X-ray spectroscopy(EDS), atomic force microscopy(AFM), vickers hardness tester, and electrochemical tester. The surface of TiN and ZrN coated wire was more smooth than that of other kinds of non-coated wire. TiN and ZrN coated surface showed higher hardness than that of non-coated surface. The corrosion potential of the TiN coated wire was comparatively high. The current density of TiN coated wire was smaller than that of non-coated wire in 0.9% NaCl solution. Pit nucleated at scratch of wire. The pitting corrosion resistance $|E_{pit}-E_{rep}|$ increased in the order of ZrN coated(300 mV), TiN coated(120 mV) and non-coated wire(0 mV).

교정치료시 하악 전치부 치은퇴축의 고려 (Gingival recession of lower anterior incisors in orthodontic treatment)

  • 김윤상;조진형
    • Journal of Periodontal and Implant Science
    • /
    • 제38권2호
    • /
    • pp.215-224
    • /
    • 2008
  • Purpose: These case reports show the orthodontic treatment of lower anterior incisors with gingival recession. Materials and Methods: Three cases were treated by an orthodontist and a periodontist. Each case had lingually tilted lower anterior incisors, anterior crossbite and skeletal Cl III pattern. Results: A variety of etiological factors were thought to cause gingival recession: aging, oral hygiene, tooth malpositioning, occlusal trauma. Conclusion: Due to the interaction among many possible contributing factors, it is difficult to predict whether further gingival recession may occur at a given site. The position and the movement of the lower anterior incisors with gingival recession are important factors in diagnosis and orthodontic treatment planning.