Bonding of brackets is one of the essential factors for successful orthodontic treatment' so bond strength of orthodontic adhesives are very important. The purposes of this research were to compare shear bond strength of various orthodontic adhesives and to evaluate failure sites. One-hundred twenty extracted human first premolars were prepared for bonding and premolar brackets were bonded to prepared enamel surfaces with Super C Ortho, Mono-$Lok^2$, Transbond, and Super C Ortho after applying Fluorobond. After bonding of brackets, teeth specimens were divided into 3 groups. In group 1 specimens were stored at humidor $37^{\circ}C$ in 1 hour, in group 2 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 10 times and in group 3 specimens were stored at humidor $37^{\circ}C$ in 24 hours, thermocycled 1800 times. Then the universal testing machine Instron 6022, Instron Co., U.S.A. was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites The results were as follows : 1. Shear bond strength was significantly highest of using Super C Ortho after applying Fluorobond and Super C Ortho In group 1, was highest of using Super C Ortho in group 2, and was highest of using Mono-$Lok^2$ in group 3. 2. According to time and temperature change, in using Super C Ortho the group 2 had significantly highest strength and group 3 had lowest strength, in using Mono-$Lok^2$ the group 2 and had higher strength than group 1 and in using Super C Ortho after applying Fluorobond shear bond strength decreased constantly, 3. The failure sites were tooth-resin interface in Super C Ortho after applying Fluorobond, Mono $Lok^2$ and Transbond and were at almost same ratio bracket base-resin interface and tooth-resin interface in Super C Orth.
본 연구는 치아미백용 2.6% hydrogen peroxide 부착대와 통상 home bleaching용으로 안전하다고 알려진 10% carbamide peroxide 미백젤이 법랑질 미세경도에 미치는 영향을 미백을 하지 않은 경우와 비교, 평가하기위하여 시행되었다. 최근에 발거한 사람의 상악 절치 20개를 사용하여 가로, 세로 2 mm의 정사각형 치아편을 각 치아에서 3개씩 절단, 채득한 후 교정용 bracket에 고정하여 시편을 제작하였다. 자원자는 20명을 선정하였고, 각각의 자원자의 치아에 동일 치아에서 제작한 시편이 부착된 bracket을 순면 중앙에 부착하였으며 상악 우측 측절치에 젤을 이용한 군 (Opalescence tooth whitening gel, Ultradent Product Inc, South Jordan, USA), 상악 우측 중절치에 미백을 하지 않은 대조군, 상악 좌측 중절치에 부착대를 이용한 군 (Claren, LG Household & Health Care, Seoul, Korea)을 부착 시켰다. 젤을 이용한 군은 bracket이 부착된 치아에 맞게 상악 우측 측절치부터 우측 소구치까지를 덮는 mouthguard tray를 제작하여 매일 동일시간에 2시간씩 14일 동안 미백을 시행하였으며, 대조군은 부착 28일 동안 미백 치료 없이 구강 내에 위치시켰다. 부착대를 이용한 군은 bracket의 시편을 덮을 수 있는 크기로 상악용 Claren을 절단하여 오전, 오후 각각 30분씩 하루 두 번 부착하여 14일 동안 미백을 시행하였다. 각군 모두 bracket부착 전, 미백 14일 후, 재광화 14일 후의 미세경도를 측정하였으며 측정된 값을 이용하여 미세경도 변화 양상과 변화량을 비교 평가하였다. 치아미백용 2.6% hydrogen peroxide 부착대와 젤 형태의 10% carbamide peroxide 미백제의 미백 전, 미백후, 재광화 후 미세경도 변화 양상이 미백을 하지 않은 대조군과 차이를 보이지 않았으며 (p > 0.05) 미백 전과 미백 후의 미세경도의 차이 미백후와 재광화 후의 미세경도의 차이도 유의할 만한 차이가 없었다 (p > 0.05). 따라서 시중에 판매되고 있는 whitening strip과 미백 젤은 14일 동안의 통상적인 미백과정 동안 법랑질의 미세경도에 영향을 미치지 않는 것으로 사료된다.
브라켓과 호선 간에 발생하는 마찰은 치아 이동의 효율에 상당한 영향을 미친다. 마찰력에 기여하는 요소 중 특히 브라켓과 호선의 표면조도는 중요한 요소이다. 본 연구는 브라켓과 탄선을 실험적으로 마찰시킨 후, 원자현미경 (atomic force microscope, AFM)을 사용하여 브라켓 슬롯과 교정용 탄선의 표면 조도 변화를 정성적, 정량적으로 측정하고 비교 평가하여 브라켓과 호선 간의 마찰이 각각의 표면 변화에 미치는 영향을 규명하고자 시행되었다. 스테인리스 스틸 브라켓과 세라믹 브라켓에 각각 스테인리스 스틸 탄선과 TMA 탄선을 실험적으로 활주마찰시킨 후 각각을 원자현미경을 이용하여 표면을 관찰하였다. 실험결과 브라켓보다는 교정용 탄선에서 활주마찰 후에 더 많은 표면 변화가 나타났다. 또한 활주마찰 후에 스테인리스 스틸 브라켓은 표면 조도의 유의한 변화가 없었으나 세라믹 브라켓은 표면 조도가 감소하였다. 그리고 교정용 탄선은 모두 활주마찰 후에 표면 조도가 증가하였으며 이러한 표면 변화는 스테인리스 스틸 브라켓보다 세라믹 브라켓과의 활주마찰 후에 더 큰 것으로 관찰되었다. 본 실험으로 원자현미경은 브라켓 슬롯과 탄선의 표면 조도를 정량적으로 측정하는 데에 유용한 수단임을 알 수 있었다.
본 연구는 침수 및 온도변화에 따른 레진 브라켓 wing의 파절양상을 비교하여 구강내 환경이 레진 브라켓 wing의 물성변화에 미치는 영향을 관찰해 보기 위하여 시행되었다. 본 연구의 재료로 레진 브라켓 75개와 금속 브라켓 25개를 사용하였는데, 레진 브라켓은 상온에서 5개월 동안 방치한 경우와 $37^{\circ}C$의 증류수에 6개월 동안 침수시킨 경우, 그리고 $37^{\circ}C$의 증류수에 6개월 동안 침수시킨 상태에서 1개월에 350회씩 총 2,100회의 열순환 시킨 경우의 3가지 군으로 구분하여 처리하였다. 만능물성 시험기를 이용하여 금속 브라켓의 경우 wing의 변형강도를, 레진 브라켓의 경우 파절강도를 각 군별로 측정하고 비교 분석하여 다음과 같은 결과를 얻었다. 1. 금속 브라켓 wing의 변형강도에 비하여 레진 브라켓 wing의 파절강도가 매우 낮게 나타났으며 통계적으로 유의한 차이가 있었다(p<0.001). 2. 상온에서 6개월 동안 방치한 군에 비하여 침수시키거나 침수 및 열순환 시킨 군에서 브라켓 wing의 파절강도가 낮게 나타났으며 통계적으로 유의한 차이를 보였다(p<0.001). 3. 단순침수에 비하여 침수 및 열순한 시킨 군의 브라켓 wing의 파절강도가 더 낮게 나타났으며 통계적으로 유의한 차이가 있었다(p<0.001). 이상의 결과는 구강내 환경에 의하여 레진 브라켓 wing의 물성이 약화되므로 이의 강도증가를 위한 적절한 대책이 필요함을 시사하였다.
Purpose: For aesthetic reasons, composite resin brackets are widely used. However, related studies are rare. This pilot study sought to compare the stress distributions in two commercially available composite resin brackets with metal slot. Materials and Methods: Two commercially available resin brackets -- full-metal slot resin bracket (fSRB) and partial-metal slot resin bracket (pSRB) with straight wire appliance dimension of $0.022{\times}0.028$ in -- were selected. In each bracket, 3-dimensional finite element models were constructed, and stress level was evaluated using finite element analysis. By loading the tipping force and torsion moment, which are similar to those applied by the stainless steel rectangular wire ($0.019{\times}0.025$ -in), stress distributions were calculated, and von Mises stress values were obtained. Results: In pSRB and fSRB, the stress value of the torque moment was much higher than that of the tipping force. The pSRB showed higher stress value than fSRB in both tipping force and torque moment because of the difference in size and configuration of the metal frame inserted into the slot. More stress was also found to be concentrated on the slot area than the wing area in fSRB. Conclusion: The slot form of fSRB was found to be more resistant to the stress of tipping and torque than the slot form of pSRB. In addition, the slot areas -- rather than the wing areas -- of the bracket showed breakage susceptibility. Therefore, resistance to the torque moment on the slot area should be considered in bracket design.
목적: 본 연구의 목적은 치열교정용 레진시멘트의 보관 조건이 치열교정용 브라켓의 접착강도에 미치는 영향을 보고자 함이다. 연구 재료 및 방법: 소의 하악 절치 순면 법랑질에 37% 인산으로 산 부식 후 치열교정용 레진시멘트인 Ortho Connect와 Orthomite를 3개월간 4℃ 냉장 보관 후 즉시 적용, 3개월간 4℃ 냉장 보관 후 24시간 동안 실온 보관하고 적용, 3개월간 24℃ 실온 보관 후 적용하는 세 조건에 따라 각 조건별로 15개의 하악 절치용 치열교정용 금속브라켓을 접착하고 광중합 한 뒤 24시간 후에 만능재료시험기로 전단접착강도를 측정하고 접착 실패 양상을 관찰하였다. 측정한 전단접착강도를 95% 유의수준에서 레진시멘트와 보관 조건에 대해 이원배치분산분석을, 레진시멘트에 보관 조건이 미치는 영향에 대해 일원배치분산분석을 했다. 결과: Ortho Connect는 냉장 보관 후 즉시 사용했을 때 가장 높은 전단접착강도를 보였으며 다른 조건 사이에는 차이가 없었다. Orthomite는 냉장 보관 후 즉시 사용했을 때 가장 낮은 전단접착강도를, 3개월 실온 보관했을 때 가장 높은 전단접착강도를 나타냈으며 이 두 조건 사이에만 유의한 차이가 있었다. 결론: Ortho Connect는 냉장 보관 후 즉시 사용해도 적절한 접착이 가능하지만, Orthomite는 냉장 보관을 한다면 충분한 실온 보관을 하는 것이 접착에 유리할 것으로 사료된다.
Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.
With modification of the acid etch technique and improvements of the physical and mechanical properties of the acrylic resin, the removal of directly bonded attachments and the finishing of the underlying enamel have become an acute clinical problem. This study was to evaluation the efficacy of recently introduced instrumentation and techniques to remove bonded brackets and residual resin, and restore the affected enamel surface to an acceptable clinical condition. Fortyeight premolar which were scheduled for extraction for orthodontic purposes were bonded with brackets using super-C ortho. Four additional premolars with untreated surfaces were used as controls. After one weak the brackets were removed and the residual resin removed by hand scaler, green stone, green rubber wheel, sandpaper disc, tungsten carbide bur, Sof-lex disc. Half the experimental teeth were given a final pumicing and then all were extracted and stored in 50 percent ethanol. The scanning electron microscopy was used to evaluated the enamel surface. Following results were obtained; 1. A satisfactory result was obtained by means of the Sof-lex disc. 2. The order of the scratch formation was the procedure using hand scaler, green atone, tungsten carbide bur, sandpaper disc, green rubber wheel, and Sof-lex disc. 3. The procedures using green stone and tungsten carbide bur showed many groove formations and the other procedures showed none. 4. final pumicing serves effectively to remove residual adhesive and restore the enamel surface.
금속 브라켓의 결합강도에 영향을 미치는 요소인 브라켓 기저부의 형태와 결합 부위에 적용되는 힘의 특성에 대해 알아보고자 연구를 시행하였다. 형태가 다른 5종의 금속브라켓의 기저부와 결합강도 측정후 접착파절양상을 stereoscope and scanning electron microscope를 통해 관찰하고 결합 부위에 적용되는 힘은 전단결합강도, 인장결합강도, 전단/인장복합결합강도로 구분하고 결합강도를 비교하여 다음과 같은 결론을 얻었다. 1. 브라켓 기저부 형태에 따른 모든 군에서 전단결합강토(SBS)가 제일 컸으며, 인장결합강도(TBS)는 SBS의 50%정도 수준이었고 전단/인장복합결합강도(S/TBS)는 전단결합강도(SBS)의 30%정도이었다. 2. 브라켓의 결합강도는 Micro-Loc base가 가장 크고($SBS:22.86{\pm}1.37kgf,\;TBS:11.37{\pm}1.43kgf,\;S/TBS:6.69{\pm}0.34kgf$), Integral base가 가장 작았다($SBS:10.52{\pm}1.27kgf,\;TBS:4.27{\pm}1.08kgf,\;S/TBS:2.94{\pm}0.58kgf). 3. 단위면적당 결합강도 비교시, Integral base가 가장 작았고(p<0.05), 전단결합강도와 인장결합강도에서는 Micro-Loc과 Chessboard base간의 차이가 없었으며 (p>0.05), Non-Etched Foil Mesh와 Micro-Etched Foil Mesh base간의 전단결합강도와 인장결합강도는 차이가 없었으나, 전단/인장복합결합강도에서는 Micro-Etched Foil Mesh base가 Non-Etched Foil Mesh base보다 더 크게 나타났다. 4. 전단, 인장, 전단/인장복합결합강도 측정후 접착파절은 브라켓/레진 계면에서 일어나 ARI score가 작게 나타났다.
치과용 금합금에 브라켓을 부착하는 경우 자연치에 비하여 낮은 결합강도를 보이며, 잦은 브라켓 탈락이 나타나고 있는 바, 본 연구는 여러 가지 금합금 표면처리 방법이 교정용 레진 접착제와 금합금 간의 전단결합강도에 미치는 영향을 평가하여 금합금과 브라켓 간의 부착강도 증진방법을 모색하고자 시행하였다. 치과용 금합금으로 주조된 240개의 시편을 표면처리 유무 및 방법에 따라 무처리, 샌드블라스팅 단독처리, 샌드블라스팅과 주석도금 병용처리, 그리고 샌드블라스팅과 중간접착제 병용처리의 4가지 경우와, Ortho-one, Panavia 21, Superbond C&B의 3가지 레진접착제의 조합에 의해 12군으로 나누어 브라켓을 부착하였다. 시편을 증류수에 담아 $37^{\circ}C$ 항온 수조 속에서 24시간 동안 보관한 후, 만능물성 시험기를 이용하여 전단결합강도를 측정한 후 다음과 같은 결과를 얻었다. 1. 치과용 금합금의 표면을 처리하지 않은 경우에 비하여 표면처리한 군에서 통계적으로 유의하게 높은 전단결합강도가 나타났다. 2. 샌드블라스팅 단독처리에 비하여 주석도금 병용처리를 시행한 경우 Panavia 21에서만 유의한 결합강도 증가가 나타났다. 3. 샌드블라스팅 단독처리에 비하여 중간접착제 병용처리를 시행한 경우 모든 접착제에서 유의한 결합강도 증가가 나타났다. 4. 사용된 레진접착제에 따른 전단결합강도를 비교한 결과 Superbond C&B가 가장 높고 그 다음으로 Panavia 21, Ortho-one 순으로 나타나는 양상을 보였다. 이상의 결과는 금합금 표면에서 브라켓 부착강도를 증가시키기 위해서는 레진접착제 종류에 관계없이 샌드블라스팅과 중간접착제 병용처리가 필요함을 시사하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.