• Title/Summary/Keyword: origin defect

Search Result 118, Processing Time 0.019 seconds

Aortopulmonary septal defect with anomalous origin of the RPA from aorta and PDA (개방성 동맥관과 우폐동맥 이상기시를 동반한 대동맥 폐동맥 중격결손증 1례 보)

  • 남구현
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.398-401
    • /
    • 1984
  • Aortopulmonary septal defect is rare congenital heart disease. An 8-year-old girl was diagnosed as a ventricular septal defect with patent ductus arteriosus at Department of Thoracic and Cardiovascular Surgery of Chungnam National University Hospital. On operation, the defect was confirmed as an aortopulmonary septal defect [Type I], anomalous origin of right pulmonary artery from aorta [Type Ill] and patent ductus arteriosus. The defect was repaired anatomically with cardiopulmonary bypass. But she was not survived because of uncontrollable bleeding from aorta.

  • PDF

Relation Between Defect State and Negative Ultra-Violet Photoresponse from n-ZnO/p-Si Heterojunction Diode

  • Jo, Seong-Guk;Nam, Chang-U;Kim, Eun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.191.2-191.2
    • /
    • 2013
  • The negative photoconductivity was frequently observed in some semiconductors. It was known that the origin of the negative photoresponse from ZnO is molecular chemisorption or the charging effect of nanoparticles in bulk matrix. However, the origin of the negative photoresponse of thin film was not still clear. One of possible explanation is due to the deep level trap scheme, which describes the origin of the negative photoresponse via defect state under illumination of light. However, the defect states below Fermi level have high capture rate by Coulomb effect, so that these states are usually filled by electrons if the defect states have donor-like character. Therefore the condition which the defect states located in below Fermi level should be partially filled by electrons make more difficult to understand of mechanism of the negative photoresponse. In this study, n-ZnO/p-Si heterojunction diodes were fabricated by UHV RF magnetron sputter. Then, some diodes show the negative photoresponse under ultra-violet light illumination. The defect state of the ZnO was analyzed by photoluminescence and deep level transient spectroscopy. To interpret the negative photoconductivity, band diagram was simulated by using SCAPS program.

  • PDF

One-stage Repair of Distal Aortopulmonary Septal Defect, Aortic Origin of Right Pulmonary Artery, Patent Ductus Arteriosus and Hypoplasia of Aortic Isthmus -A case of report- (대동맥 협부 발육부전, 동맥관 개존, 대동맥기시 우폐동맥을 동반한 원위 대동맥폐 동맥 중격결손의 일차 완전 교정술 1례)

  • 이호철;류한영
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.554-558
    • /
    • 1996
  • A case of distal aortopulmonary septal defect associated with aortic origin of right pulmonary ar- tery, patent ductus arteriosus and hypoplasia of aortic isthmus in a 50-day-old female infant is presented. Ligation of patent ductus arteriosus, resection and end-to-end anastomosis of hypoplasia of aortic isthmus, implantation of rlght pulmonary artery to main pulmonary artery and autologous peri- cardial patch repair of aortopulmonary septal defect were performed under cardiopulmonary bypass as one-stage approach. Deep hypothermic total circulatory arrest was applied during repair of hypoplasia of aortic isthmus. The p stoperative course was uneventful.

  • PDF

Distal Type of Aortopulmonary Septal Defect with Aortic Origin of Right Pulmonary Artery and Interruption of the Aortic Arch - A Case of Successful Surgical Report -

  • Jeong, Yun-Seop;Song, Myeong-Geun
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.693-700
    • /
    • 1991
  • A rare case of the association of distal aortopulmonary septal defect, aortic origin of the right pulmonary artery, intact ventricular septum, patent ductus arteriosus and interrupted aortic isthmus in a 40-day-old infant is reported. The infant was suffered from two operations with an interval of nine days. At the first operation a 10mm polytetrafluoroethylene prosthesis was inserted instead of the interrupted aortic isthmus and ductus was ligated via the left posterolateral thoracotomy. But the patient could not be weaned from the respirator because of large amount of left-to-right shunt. So the total correction was subsequently performed after an interval of nine days. At the second operation, tunneling of the right pulmonary artery to the main pulmonary artery through the aortopulmonary septal defect was performed using the Dacron patch via a longitudinal transaortic approach and a separate autologous pericardial patch was applied to the longitudinally incised margins of the anterior wall of the ascending aorta. The second postoperative course was relatively uneventful except some respiratory distress and nutritional problems. Now he is at 6 months of age and thrives well without any symptom. Because the success of the surgical repair of this complex anomalies depends upon the accurate diagnosis and meticulous design of each step of procedure prior to operation these problems are also discussed.

  • PDF

Surgical Removal of Intrathoracic Lipoma from Herniated Omentum through the Diaphragmatic Defect in an Abyssinian Cat

  • Lee, Jiyeon;Park, Hyojin;Kim, Jieyoo;Kim, Na-Hyun;Lee, Dongbin;Lee, Hee-Chun;Hwang, Tae-Sung;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.38 no.4
    • /
    • pp.174-178
    • /
    • 2021
  • A nine-year-old neutered male cat was presented with chronic cough and vomiting. Thoracic radiography showed regions of fatty opacity in the right caudoventral region. On positive contrast celiography, contrast agent did not move into thoracic cavity. Computed tomography revealed 7-mm diameter of defect at the right diaphragmatic crus and a 2-mm diameter defect at the left ventral diaphragmatic crus. Through the right diaphragmatic defect omental herniation was confirmed by the presence of contrast enhanced omental vessel running across the diaphragm. On exploratory thoracotomy, the omentum protruded into the thorax through the right diaphragmatic defect, and it contained a yellowish lipomatous mass. The protruded omentum containing a mass in the thorax was removed, and the right diaphragmatic defect was closed. Histopathologic examination revealed that the protruded omentum showed normal omental structure and the adipose mass showed lipoma surrounded by fibrous tissue. In conclusion, a thorough examination is necessary to confirm the origin of the mass located near the diaphragm.

Ruptured Sinus of Valsalva Aneurysm - A Case Report - (대동맥동 동맥류 파열 - 1례 보고 -)

  • Kim, Seong-Su;Jo, Jung-Gu;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.687-692
    • /
    • 1989
  • Aneurysm of the sinus of Valsalva is an uncommon cardiac anomaly, usually congenital in origin, which may occur as an isolated defect or in conjunction with other cardiac malformation. This report is a case of a ruptured sinus of Valsalva aneurysm with ventricular septal defect in a 18-year-old female patient who complained progressive exertional dyspnea. She underwent operative management using total cardiopulmonary bypass. The fistula originated from the right coronary sinus and ruptured into the right ventricle and coexistent lesion was supracristal ventricular septal defect. The repair was done through aortic and right ventricular approach. The ruptured sinus of Valsalva was closed with pledget suture and the ventricular septal defect was closed with patch. The postoperative result was good.

  • PDF

Identifying and quantitating defects on chemical vapor deposition grown graphene layers by selected electrochemical deposition of Au nanoparticles

  • So, Hye-Mi;Mun, Jeong-Hun;Bang, Gyeong-Sook;Kim, Taek-Yong;Cho, Byung-Jin;Ahn, Chi-Won
    • Carbon letters
    • /
    • v.13 no.1
    • /
    • pp.56-59
    • /
    • 2012
  • The defect sites on chemical vapor deposition grown graphene are investigated through the selective electrochemical deposition (SED) of Au nanoparticles. For SED of Au nanoparticles, an engineered potential pulse is applied to the working electrode versus the reference electrode, thereby highlighting the defect sites, which are more reactive relative to the pristine surface. Most defect sites decorated by Au nanoparticles are situated along the Cu grain boundaries, implying that the origin of the defects lies in the synthesis of uneven graphene layers on the rough Cu surface.

Aorticopulmonary Window: one case report (대동맥중격결손증[수술치험 1예])

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.302-306
    • /
    • 1981
  • Aorticopulmonary window is a rare anomaly among congenital heart disease. Various terms have been suggested including A-P window, A-P fenestration, fistula, aorticseptal defect etc. The defect lies usually between the left side of the ascending aorta and right wall of the pulmonary artery just anterior to the origin of the right main pulmonary artery. We have experienced one case of aorticopulmonary septal defect which was diagnosed as V5D with pulmonary hypertension in 1 4/12 year old, 7.2 Kg, male patient. Operation was done under the hypothermic cardiopulmonary bypass using 5t. Thomas cardioplegic solution. Vertical right ventriculotomy over the anterior wall of RVOT revealed no defect in the ventricular septum, and incision was extended up to the main pulmonary artery to find the source of massive regurgitation of blood through MPA. Finger tip compression of the aorticopulmanary window was replaced with Foley bag catheter balloon, and the $7{\times}10$ mm aorticoseptal defect located 15mm above the pulmonic valve was sutured continuously wih 3-0 nylon suture during azygos flow of cardiopulmonary cannula which was located distal to the window resulted massive air pumping systemically, and temporary reversal of pumping was tried to minimize cerebral air embolism. Remained procedure was done as usual, and pump off was smooth and uneventful. Postoperatively, patient was attacked frequent opistotonic seizure with no recovery sign mentally and p.hysically. Vital signs were gradually worsen with peripheral cyanosis and oliguria, and cardiac activity was arrested 1485 minutes after operation. Autopsy was performed to find the sutured window and massive edema of the brain.

  • PDF

Technique of Coronary Transfer for TGA with Single Coronary Artery

  • Kim, Tae Ho;Jung, Jae Jun;Kim, Yong Han;Yang, Ji-Hyuk;Jun, Tae-Gook
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.529-532
    • /
    • 2014
  • An eight-day-old neonate was diagnosed with dextro-transposition of the great arteries, atrial septal defect, patent ductus arteriosus, and a single sinus origin of the coronary arteries. The single coronary artery originated from the left sinus (sinus 2), had a proximal left circumflex arterial branch, and passed anteriorly to the right side of the aorta, further branching into the right coronary and left anterior descending arteries. We successfully performed an arterial switch operation and coronary transfer by tube graft reconstruction with autologous aortic tissue to treat the dextro-transposition of the great arteries and atrial septal defect with a single-sinus origin of the coronary arteries.