• 제목/요약/키워드: orifice method

검색결과 215건 처리시간 0.023초

프리 플로우트 스팀트랩 밸브의 오리피스 지름 변화에 따른 작동 원리 및 응축수 배출량에 관한 연구 (Study of Performance Properties and Steam Condensate Capacity by Orifice Diameters of Free Float Steam Trap Valve)

  • 최인규;강정호
    • 한국기계가공학회지
    • /
    • 제15권2호
    • /
    • pp.31-37
    • /
    • 2016
  • In the steam system, a stream trap valve discharges a condensate and a non-condensable gas. It also prevents stream from being leaked. The free float stream trap valve is a mechanical type of stream trap. The valve is opened when a hallow ball is floated due to the density of the condensate through the condensate flows into the valve. On the other hand, when the flow of the condensate is completed, the valve is closed as the float subsides due to the weight of the structure and the stream is blocked. In addition, the bimetal lifts the hallow ball, which discharges the non-condensable gas. In this study, the performance of the properties of the free float stream trap valve, the method of support for three points, and the orifice design are researched. Moreover, the condensate discharge capacity of the free float stream trap valve is calculated from the experiment.

AMESim기반 피에조 인젝터용 해석모델의 민감도 특성 해석 (Analysis of Sensitivity Characteristics with AMESim Model for Piezo Injector)

  • 조인수;권지원;이진욱
    • 한국자동차공학회논문집
    • /
    • 제21권2호
    • /
    • pp.17-25
    • /
    • 2013
  • Performance of DI diesel engine with high fuel injection method is directly related to the emission characteristics and fuel consumption. At present, diesel injection system with piezo element is replacing conventional solenoid type due to their faster electro-mechanical properties. In this study, it was investigated the sensitivity characteristics regarding internal hydraulic modeling based on the AMESim environment of piezo-driven injector The analytic parameter for this study defined such as In/Out orifice, injection hole's diameter and driven voltage on piezo stack. As the results, it was shown that these parameter influence on a fast response characteristics of piezo-driven injector. Also we found fuel pressure recovery time is faster about 0.1 ms due to larger IN orifice diameter. And larger OUT orifice diameter occurs maximum pressure drop with faster its timing of about 0.2 ms.

충격파 감금법을 이용한 배기가스 유동의 새로운 처리법에 관한 연구 (New Treatment of High-Pressure Exhaust Gas Flows Using Shock-Wave Confinement)

  • 김희동;김태호;우선훈
    • 한국추진공학회지
    • /
    • 제2권1호
    • /
    • pp.78-87
    • /
    • 1998
  • 본 연구에서는 유로의 상류와 하류에 오리피스를 가지는 일정 단면적의 관로에 충격파를 감금시킴으로써, 고압력의 배기가스 유동을 감압처리하는 새로운 방법을 시도하였다. 이론해석에서는 일차원 점성 압축성 유동이론을 두 오리피스를 가지는 내부유동에 적용하여 이론계산을 수행하였다. 실험에서는 충격파 풍동을 이용하여, 압력측정과 유동장의 광학관찰을 수행하였다. 그 결과 충격파를 관내에 감금하기 위해서는 관의 마찰계수를 크게 하는 것이 바람직하다는 것을 알았다. 또 상류 오리피스의 단면적을 일정하게 하는 경우, 하류의 오리피스 단면적을 변화시킨다고 하더라도 전압의 감소량은 크게 변화하지 않았으나, 하류 오리피스의 단면적을 일정하게 하는 경우, 상류 오리피스의 단면적을 작게 할수록 전압감소량은 커진다는 것을 알았다. 본 연구의 결과는 각종 플랜트에서 발생하는 고압의 배기가스유동에 대한 새로운 처리법으로 유용하리라 판단된다.

  • PDF

이중 오리피스 연료 노즐 최적설계 (Optimum Design of Dual Orifice Fuel Nozzle)

  • 임오강;최은호;김성섭
    • 한국전산구조공학회논문집
    • /
    • 제20권4호
    • /
    • pp.407-416
    • /
    • 2007
  • 가스터빈에서 연료 분무 노즐은 연소 특성에 영향을 미치는 중요한 부품이다. 스월 분무 장치를 설계하기 위하여 유량과 분무액적 평균 직경을 설계변수로 정하고 연료 분무 노즐의 최적화를 수행하였다. 설계변수는 이중 노즐의 실험값들을 비교하여 중요한 영향을 미치는 변수로 선정하였다. 민감도는 유량과 분무액적 평균 직경의 변화에 따른 값을 사용하였다. 이중 오리피스형 스월 분무장치의 형상 최적설계를 통하여 유량의 미립화를 높이도록 연구하였다. 최적설계를 위하여 실험 계획법을 이용하였으며, 영향을 적게 미치는 설계변수들은 설계대상에서 제외하였다. 분무 노즐의 분무액적 평균 직경을 사용한 결과는 Jasuja의 액적 평균 이론을 이용하여 도출된 결과와 유사함을 알 수 있었다. 연구 결과는 이중 오리피스형스월 분무장치와 이와 비슷한 종류의 노즐 최적화를 위한 특성을 파악하고 최적의 유량과 허용 공차를 제시하였다.

Evaluation of the Induction and Ionized Field Charging Methods for Electrostatic Nozzles of Orchard Sprayer

  • Laryea, G.N.;No, S.Y.;Lee, D.H.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.29-34
    • /
    • 2002
  • Two charging methods of electrostatic nozzle, i.e. induction and ionized field corona charging, were designed and evaluated for orchard sprayer application. An artificial (metallic) target was constructed and used in this experiment. The charge-to-mass ratio for the induction electrode was measured by using the Faraday cage. Two conventional pressure-swirl nozzles have been employed with different orifice diameters under the same experimental operating conditions. A commercial pressure-swirl nozzle with orifice diameter of 1.0 was used for the conventional spray. The diameter of the electrostatic was 0.59 mm. The experiment was carried out for individual nozzle sprays at $0^{\circ}$, $20^{\circ}$ and $50^{\circ}$ oriented angles and three nozzles, sprayed simultaneously at a distance of 1.0 and 2.0 m from the nozzle tip to the target. The nozzles were mounted on a carriage with constant speed of 1.26 km/h with a blower attached. The weighing method was employed to evaluate for the spray deposition, ground loss and estimated drift. The results show more promising for the induction charging method, especially at $20^{\circ}$oriented angle at a distance of 1.0 m from the target for a single nozzle and when all three nozzles were operated simultaneously for spray deposition. The results of the induction charging method show promising with the developed electrostatic technique.

  • PDF

차량 고급감 향상을 위한 흡배기계 음질지수 개발 (A Development of Sound Quality Index of an Intake and Exhaust System for High Quality Improvement of Luxury Vehicles)

  • 이종규;조덕형;서대원;임윤수;원광민
    • 한국소음진동공학회논문집
    • /
    • 제22권3호
    • /
    • pp.234-243
    • /
    • 2012
  • In this paper, a sound quality indices for the evaluation of vehicle intake and exhaust noise were developed through a correlation analysis of objective measurement data and subjective evaluation data. At first, intake and exhaust orifice noise were measured at the wide-open throttle sweep condition. And then, acoustic transfer function between intake orifice noise and interior noise at the steady state condition was measured. Also, acoustic transfer function for exhaust system was measured as the same method. Simultaneously, subjective evaluation was carried out by the paired comparison and semantic differential method by 27 engineers. Next, the correlation analysis between the psycho-acoustic parameters derived from the measured data and the subjective evaluation was performed. The most critical factor was determined and the corresponding sound quality index for the intake and exhaust noise was obtained from the multiple factor regression method. At last, the effectiveness of the proposed index was investigated.

액적 발생기의 종류 및 액적 발생 원리에 대한 고찰 (A Survey on the Droplet Generators and Principle of Droplet Generation)

  • 박봉엽;한재섭;김선진;김유
    • 한국추진공학회지
    • /
    • 제4권2호
    • /
    • pp.54-60
    • /
    • 2000
  • 액적 발생기는 Rayleigh의 액적 분열 이론에 기초한 액적 발생기가 주류를 이루고 있으며, 모세관 액주의 진동 방법에 따라 여러가지 액적 발생기가 고안되었다. 현재는 액전 발생의 표준장비로 VOAG(Vibrating Orifice Monodisperse Aerosol Generate)가 사용되고 있다. 단일 액적을 사용한 연소실험에는 적하방법이나 필라멘트에 매달린 액적을 분리하여 사용하는 방법이 더 효과적임을 알았다 단일 액적을 분리하는 방법은 액적을 대전시켜 액적 흐름에서 단일 액적을 분리하는 방법을 사용한다.

  • PDF

수치해석을 이용한 코그메틱용 스프레이 미립화를 위한 부품설계 및 금형 설계에 과한 연구 (A study about design of main parts and injection molds for atomization of cosmetic spray using finite element method)

  • 서형진;손창우;장영주;양우;서태일
    • Design & Manufacturing
    • /
    • 제9권2호
    • /
    • pp.25-29
    • /
    • 2015
  • This paper presented characterization of spray velocity and angle of spray nozzle systems for cosmetic products. Diameter and length of nozzle orifice were chosen as shape factors of the spray system. Spray orifice of the spray pattern is a factor influencing the quality of the product. Fluid analysis was conducted by using "Fluent" to obtain spray angle and velocity. RSM (Response Surface Method) was used to approximate the relationship between these 2 factors and spray characteristics. To evaluate the proposed method, experimental work with existing was conducted and good agreement between simulation and experimental results.

  • PDF

증기발생기 내 냉각수 분사 노즐로의 냉각수 공급 방법에 관한 연구 (Study on the cooling water supply method to the cooling water injection nozzle in the steam generator)

  • 오정화;신민규;조영석;고영성
    • 항공우주시스템공학회지
    • /
    • 제14권5호
    • /
    • pp.66-72
    • /
    • 2020
  • 본 연구에서는 증기발생기 내부로 냉각수 공급 시 화염에 의한 냉각수 분사 노즐 손상이 없도록, 초반 냉각수 공급량을 늘리는 방안에 대한 연구를 진행하였다. 초기 증기발생기 시험 시 벤추리만 사용하여 유량을 제어하였는데, 초반 유량 안정화 구간 동안 연소실 내부로 냉각수 공급이 되지 않아 냉각수 노즐의 손상이 발생하였다. 이를 해결하기 위해 벤추리와 오리피스를 병렬로 구성하여, 초반 공급 유량을 늘림으로써 냉각수 매니폴드와 연소실 사이 차압을 형성시켜 냉각수를 공급하였다. 수류시험을 통해 벤추리와 오리피스 공급 시퀀스를 확립하였으며, 최종 검증을 위해 연소실험을 진행하였다. 실험 결과 연소 초반 지속적으로 냉각수를 공급하는 것을 확인하였으며, 냉각수 노즐 손상 없이 성공적으로 실험을 수행하였다.

공기보조식 와류 노즐의 저압 분무특성 (Spray Characteristics of Air-assisted Vortex Nozzle at Low Pressure Condition)

  • 김우진;비멀;최장수
    • 한국분무공학회지
    • /
    • 제20권2호
    • /
    • pp.82-87
    • /
    • 2015
  • A nozzle with vortex generator was used to develop the low pressure nozzle with high atomization performance and the nozzle atomized the liquid by centrifugal shear forces. In order to analyze the atomization characteristics, a shadowgraphy method was used and the measurement of droplet size was performed by using laser diffraction analyzer. The liquid injection pressure was fixed as 0.03 bar which is very low pressure and the gas injection pressures were changed from 0 bar to 2.0 bar. As a result, the breakup was achieved at the air injection pressure of 0.25 bar and over. The nozzle with the orifice diameter of 0.4 mm and the orifice gap of 0.25 mm presented small droplet diameters under 50 at the air injection pressure of 0.75 bar.