• Title/Summary/Keyword: organic wastewater treatment

Search Result 808, Processing Time 0.024 seconds

Deduction of Optimum Factors for Hydrogen Production from Organic Resources using a Continuous Reaction Process (연속반응공정을 이용한 유기성자원으로부터 수소생산을 위한 최적인자도출에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.22-27
    • /
    • 2011
  • This study was performed to find out the optimum condition for hydrogen production by changing mixture ratio from 3:7(food waste water : swine wastewater) without pre-treatment of food wastewater and swine wastewater using a continuous reaction process. It was confirmed that hydrogen generation according to pH is the highest in a condition of pH 5.5, and that the optimum pH for hydrogen production in case of mixing food wastewater with swine wastewater is 5.5 through this. Hydrogen generation according to HRT showed high hydrogen generation rate in case of 4 days rather than 3 days, and this involves largely in vitality of hydrogen producing bacteria according to variation of the HRT value, so it is judged that HRT also acts as an important factor to hydrogen producing bacteria. The organic removal efficiency recorded a removal efficiency of maximum TS 52%, VS 71%, TSS 83% and VSS 89% at the 6th day of operation, and it was confirmed that organic removal efficiency is possible even through an hydrogen production process.

Nutrients removal enhancement using a modified rotating activated bacillus contactor (RABC) process (수정 RABC 공정을 이용한 영양염류 제거능 제고에 관한 연구)

  • Kim, Sunhee;Kim, Donghwan;Jang, Giung;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.99-104
    • /
    • 2016
  • This study was performed to develop a new process technology for advanced wastewater treatment using a modified Rotating Activated Bacillus Contactor (RABC) process that adopts anoxic-oxic suspended biomass tanks to enhance nutrients removal. A modified lab-scale RABC process was applied to examine its applicability and to obtain the design factors for the optimum operation of the system. The modified RABC process showed a little more stable and high nutrients removal efficiency than the prototype RABC process: about 70% of nitrogen and 55% of phosphorous removal when the low organic loading (influent COD 200mg/L). However, the processing efficiency of nutrients removal rates was enhanced to great extent when high organic loading: nitrogen 90% and phosphorous 85% (influent COD 500mg/L). High organic loading stimulated extremely good biomass attachment on the reticular carrier RABC stage and the excellent nutrients removal, nevertheless with almost no offensive odor.

Measurement of Biological Activity in Pharmaceutic Wastewater by Using Respirometer (호흡률 측정기를 이용한 제약폐수의 생물학적 활성 측정)

  • 이영락;이기용;임지훈;이상훈;문흥만;심상준;이진원
    • KSBB Journal
    • /
    • v.16 no.2
    • /
    • pp.183-187
    • /
    • 2001
  • The biological activities of wastewater and sludge taken from the wastewater treatment process of Hyangnam pharmaceutic factories in Hwaseong, Kyeonggi-Do was measured using a respirometer. Oxygen uptake rate (OUR) was used as a tool for measuring biological activity. OUR was measured for varying amounts of sludge and organic chemicals in wastewater, and its toxicity was evaluated. Maximum OUR was observed as 61, 75, and 89 mg O$_2$/L/hr when sludge was added as 3, 5, and 10% of total volume, respectively. When the concentration of organic chemicals was changed to 1,486, 337, and 164 mg COD/L, maximum OUR was 53, 13, 8 mg O$_2$/L/hr, respectively. The toxicity test results showed that there seemed that there seemed to be no observable toxic effect on microbes in pharmaceutic wastewater.

  • PDF

Applications of Ozone Micro- and Nanobubble Technologies in Water and Wastewater Treatment: Review (정수 및 폐수처리에서 오존 미세기포와 초미세기포 기술의 적용 : 리뷰)

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.481-490
    • /
    • 2017
  • Water and wastewater treatment has always been a challenging task due to the continuous increase in amount and the change in characteristics of the poorly biodegradable and highly colored organic matters, as well as harmful micro-organisms. Advanced techniques are therefore required to successfully remove these pollutants from water before reuse or discharge to receiving water bodies. Application of ozone, which is a powerful oxidant and disinfectant, alone or as part of advanced oxidation process depends on the complex kinetic reactions and the mass transfer of ozone involved. Micro- and nano bubbling considerably improves gas dissolution compared to conventional bubbles and hence mass transfer. It can also intensify generation of hydroxyl radical due to collapse of the bubbles, which in turn facilitates oxidation reaction under both alkaline as well as acidic conditions. This review gives the overview of application of micro- and nano bubble ozonation for purification of water and wastewater. The drawbacks of previously considered techniques and the application of the hydrodynamic ozonation to synthetic aqueous solutions and various industrial wastewaters are systematically reviewed.

Trends of microbial electrochemical technologies for nitrogen removal in wastewater treatment (하폐수처리에서 질소 제거를 위한 미생물 전기화학 기술의 동향)

  • Chai, Hyungwon;Choi, Yonghoon;Kim, Myeongwoon;Kim, Youngjin;Jung, Sokhee P.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.5
    • /
    • pp.345-356
    • /
    • 2020
  • The removal of organic carbon and nutrients (i.e. N and P) from wastewater is essential for the protection of the water environment. Especially, nitrogen compounds cause eutrophication in the water environment, resulting in bad water quality. Conventional nitrogen removal systems require high aeration costs and additional organic carbon. Microbial electrochemical system (MES) is a sustainable environmental system that treats wastewater and produces energy or valuable chemicals by using microbial electrochemical reaction. Innovative and cost-effective nitrogen removal is feasible by using MESs and increasing attention has been given to the MES development. In this review, recent trends of MESs for nitrogen removal and their mechanism were conclusively reviewed and future research outlooks were also introduced.

Treatment of highly concentrated organic wastewater by high efficiency $UV/TiO_{2}$ photocatalytic system (고효율 자외선/광촉매 시스템을 이용만 고농도 유기성 폐수처리)

  • Kim, Jung-Kon;Jung, Hyo-Ki;Son, Joo-Young;Kim, Si-Wouk
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.83-89
    • /
    • 2008
  • Food wastewater derived from the three-stage methane fermentation system developed in this lab contained high concentration organic substances. The organic wastewater should be treated through advanced wastewater treatment system to satisfy the "Permissible Pollutant Discharge Standard of Korea". In order to treat the organic wastewater efficiently, several optimum operation conditions of a modified $UV/TiO_{2}$ photocatalytic system have been investigated. In the first process, wastewater was pre-treated with $FeCl_{3}$. The optimum pH and coagulant concentration were 4.0 and 2000mg/L, respectively. Through this process, 52.6% of CODcr was removed. The second process was $UV-TiO_{2}$ photocatalytic reaction. The optimum operation conditions for the system were as follows: UV lamp wavelength, 254 nm; wastewater temperature, $40^{\circ}C$; pH 8.0; and air flow rate, 40L/min, respectively. Through the above two combined processes, 69.7% of T-N and 70.9% of CODcr contained in the wastewater were removed.

Evaluation of Autoheated Thermophilic Aerobic Digestion Process for the Treatment of Pig Manure Wastewater (돈사폐수의 고온 호기성 소화공정 적용 타당성 평가)

  • Chung, Yoon-Jin;Cho, Jong-Bok;Lee, Jin-Yong;Lee, Jong-Hyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.2
    • /
    • pp.103-114
    • /
    • 1995
  • Since autoheated thermophilic aerobic digestion (ATAD) process has various advantages for the treatment of high-strength organic wastewater, active research and field application has been applied in U.S.A. and Canada, recently and the interest in ATAD process has been elevated for treating high-strength organic wastewater efficiently in Korea. Therefore, various experiments were carried out to evaluate the feasibility of ATAD process for the treatment of pig manure wastewater. The results of this study showed possibility to reuse pig manure wastewater as wet fodder or liquid compost, since ATAD process led excellent stabilization on the basis of odor and putrefaction. However. digested sludge can not be provided as wet fodder to most of hog farms without changing dry feeder system into wet system and as liquid compost to hog farms not having their own grass land. Since the results showed that the increase of temperature in reactor was resulted not from energy by biological activity. but from mechanical mixing energy. the reactor investigated in this study was against the principle of ATAD process. Therefore. if pig manure wastewater treated by ATAD can not be utilized as wet fodder. it is not economical to adopt ATAD process only for the treatment of wastewater.

  • PDF

A Study on Reuse System of Dyeing Wastewater using Membrane (막을 이용한 염색폐수의 재활용 연구)

  • 서명포
    • Textile Coloration and Finishing
    • /
    • v.10 no.4
    • /
    • pp.45-52
    • /
    • 1998
  • Reuse of wastewater become an important consideration to solve the environmental pollution problems in recent industriallzation and urbanization. Especially, he characteristic of dyeing process is subject to use much water and thus has serious problems for removal of color and organic pollutants in their wastewater. This report is divided into two main parts : The purpose of the first part was to determine if alkaline wastewater discharged from textile dyeing operation factory could be flocculated directly by Fenton oxidation method. This study was conducted to investigate Fenton reagent dose and reaction condition of Fenton method as pretreatment for dyeing wastewater in K dyeing industry were investigated. In the second part of this research, to treat dyeing wastewater it was found that the most effective way is to use ultrafiltation and reverse osmosis at the conditions of the pH 7.0~8.0 and operating pressure of $2.5~35kg_f/cm^2$. This paper is mainly dealt with the application on reuse system of dyeing wastewater treatment using ultrafiltration and reverse osmosis membranes. The results showed that dyeing wastewater could be reused by chemical, filter and membrane sequential treatment process.

  • PDF

Photo and Electrocatalytic Treatment of Textile Wastewater and Its Comparison

  • Singaravadivel, C.;Vanitha, M.;Balasubramanian, N.
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Electrochemical and photochemical techniques have been proved to be effective for the removal of organic pollutants in textile wastewater. The present study deals with degradation of synthetic textile effluents containing reactive dyes and assisting chemicals, using electro oxidation and photo catalytic treatment. The influence of various operating parameters such as dye concentration, current density, supporting electrolyte concentration and lamp intensity on TOC removal has been determined. From the present investigation it has been observed that nearly 70% of TOC removal has been recorded for electrooxidation treatment with current density 5 mA/$dm^2$, supporting electrolyte concentration of 3 g/L and in photocatalytic treatment with 250 V as optimum lamp intensity nearly 67% of TOC removal was observed. The result indicates that electro oxidation treatment is more efficient than photocatalytic treatment for dye degradation.

A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill leachate (공공하수처리시설에서 수질오염물질 유입 및 배출 특성 고찰 - 산업폐수 및 매립지 침출수 연계처리 시설을 중심으로 -)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Kyung-Hee;Kim, Eunseok;Kim, Changsoo;Chung, Hyen-Mi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.673-682
    • /
    • 2016
  • In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on "Water Quality Monitoring Networks" in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.