• 제목/요약/키워드: organic solvents

검색결과 1,215건 처리시간 0.035초

A Simple Phenol‐Indole Dye as a Chromogenic Probe for the Ratiometric Determination of Water Content in Organic Solvents

  • Kim, Kyoung- Nam;Song, Ki-Cheol;Noh, Jae-Hyun;Chang, Suk-Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.197-200
    • /
    • 2009
  • A simple dye having phenol and indole moieties was synthesized and its chromogenic signaling behaviors for the determination of water content in organic solvents were investigated. The compound revealed a pronounced chromogenic behavior in response to the variation of water content in water miscible aprotic organic solvents of acetone, acetonitrile, THF, and dioxane. Significant red shifts and changes in absorption spectra allowed a ratiometric analysis of the signaling behavior. The chemosensing behaviors were particularly pronounced in water content in less than 10% that is suitable for the application of the compound as a probe for the determination of water content in binary aqueous organic solutions having lower water content.

자동차 정비공의 혈액 및 뇨검사 소견과 자각증상에 대한 조사 (Laboratory Findings and Subjective Symptoms of Car Repair Workers)

  • 이광성;이명구;조영채
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.80-87
    • /
    • 1998
  • To evaluate the effects on health by exposure to low dose organic solvents, the author analyzed the air concentration of mixed organic solvents (toluene, xylene, butylacetate) at worker's breathing zone during painting, some laboratory findings of blood (WBC, RBC, Hb, Hct, SGOT, SGPT, TC, TG, HDL-C, LDL-C, IgG, IgM, IgA and IgE) and urine (hippuric acid, urinary protein, urobilinogen), surveyed the subjective symptoms those were obtained from 35 male workers exposed to mixed organic solvents, and 25 male workers not exposed to organic solvents who worked in car repair workshops in Taejon area from December 1, 1995, to February 29, 1996. The results were as follows: 1. The mean concentration of urinary hippuric acid of car painting worker group (organic solvent exposure group) was 0.76$\pm$ 0.21 g/l, which is significantly higher than that of non-exposed group. 2. In hematologic findings, the values of RBC, TC, LDL-C, IgG and IgE in the exposure group were significantly lower than those of the nonexposed group, but SGOT and SGPT in the exposure group were significantly higher than those of the non-exposed group. 3. Urinary hippuric acid levels showed positively correlated with toluene, urobilinogen and HDL-C levels, but those were negatively correlated with RBC, LDL-C, IgM levels. 4. Rates of the subjective symptoms such as "dizziness", "appetite loss", "weight loss", "palpitation", "chest tightness", "sore throat and eye discomfort", "tingling sense and acrodynia", "illusion or hallucination" and "decreaased motor power" were significantly higher in the exposure group than those of the non-exposed group.

  • PDF

확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성 (Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field)

  • 장성호;김형아
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

PhosBholipase D에 의한 비천연 인지방질의 합성: IIl 포스타티딜기 전이반응에 미치는 유기용매의 효과 (Biosynthesis of Unnatural Phospholipids by Phospholipase D: II. Effect of Organic Solvents on Transphosphatidylation)

  • 정의호;이해익이상영
    • KSBB Journal
    • /
    • 제6권3호
    • /
    • pp.281-288
    • /
    • 1991
  • This research was carried to investigate the effects of several organic solvents on the enzymatic transphosphatidylation in emulsion and two-phase solvent systems. The solvents having a similar dielectric constant with diethylether were effective for the enzyme activity. Diethylether and butylacetate were the most effective solvents, when added 12-15%(v/v) and 10-40%(v/v), respectively, for the synthesis of phosphatidylglycerol, phosphatidylethyleneglycol and phosphatidylpropyleneglycol. In the emulsion system, the size of ovolecithin liposome was increased and the clearness of the phospholipid bilayer was reduced as increasing the diethylether concentration. In the twophase solvent system, the rapidest reaction was obtained when water-organic solvent ratio was close to 1. The ratio of aqueous phase. however, should be lowered to 37% to gain the sole product of transphosphatidy1ation, without phosphatidohydrolysis.

  • PDF

Synthesis and Characterization of Fluorinated Polybenzoxazole Copolymers

  • Sohn, Jeong Sun;Park, A Ram;Choi, Jae Kon
    • Elastomers and Composites
    • /
    • 제50권3호
    • /
    • pp.175-183
    • /
    • 2015
  • A series of fluorinated aromatic poly(hydroxyamide)s (PHAs) were synthesized by direct polycondensation of diacides containing 2,6-dimethylphenoxy group and quinoxaline ring in the main chain with 2,2-bis-(3-amino-4-hydroxyphenyl) hexafluoropropane. The PHAs had relatively low inherent viscosities in the range of 0.35~0.43 dL/g at $35^{\circ}C$ in DMAc solution. All PHAs exhibited excellent solubility in aprotic solvents such as NMP, DMAc, DMF and DMSO as well as in common organic solvents such as pyridine, THF, and m-cresol at room temperature. However, the poly(benzoxazole)s (PBOs) were quite insoluble in all organic solvents except partially soluble in concentrated sulfuric acid. The PBOs showed glass transition temperatures between 233 and $284^{\circ}C$ by DSC and maximum weight loss temperatures in the range of $536-546^{\circ}C$ by TGA.

일부 세탁소의 유기용제 관리실태 및 공기중 노출농도에 관한 조사 (A Survey on the Management of Chemical Substances and Airborne Concentration in Laundries Exposed to Organic Solvents)

  • 노영만;권기범;박승현;정지연
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.70-77
    • /
    • 2001
  • This study was conducted to identify the current status of occupational safety and health by checklist and to evaluate the airborne exposure to chemicals and to provide the appropriate recommendation for safety and health of laundries. A total of 20 laundries located in tile Gyungi district area were surveyed from July 20 to September 15, 2000. The prevalence of laundries having a stove and gas range were found to be 25 % and 55 %, respectively. Smoking is not allowed in 60 % of the laundries. Only 10 % of dry-cleaners were isolated. Ventilation systems in laundries had not been annually inspected. Most of the workers didn't put on respirators, MSDS were not available, and storage bottles did not contain warning labels. The bulk samples of dry cleaning agent include many chemicals that are not controlled by the MOL in Korea. The detected airborne organic solvents in the laundries were benzene, toluene, p-xylene, m-xylene, o-xylene, perchloroethylene, and 2-butoxy ethanol. The airborne concentrations of organic solvents were much less than the occupational exposure limits proposed by the Ministry of Labor(MOL) in Korea. But the concentrations of benzene exceeded the TLV of ACGIH. This study showed that the current status of occupational safety and health was not appropriate for workers in laundries. It is recommended that laundry workers should be educated for the treatment and storage of hazardous organic solvents to improve the occupational safety and health of the working environment as well as MSDS usage. Also, extended research and survey for the organic solvents that are not controlled by the MOL has to be conducted.

  • PDF

미용실(Beauty salon) 근로자들의 유기용제 폭로와 자각증상에 관한 연구 (Exposure of Organic Solvent Mixtures and Subjective Symptoms to Beauty-Salon Workers)

  • 이창은;심상효
    • 한국환경과학회지
    • /
    • 제18권3호
    • /
    • pp.345-353
    • /
    • 2009
  • The purpose of this study is to examine the health of beauty salon workers through the utilization of questionnaires concerning the extent of exposure to organic solvents found in the air of some beauty salons and any resultant symptoms in employees. The subjects were 36 employees from 10 beauty salons who agreed to participate in this study. The degree of exposure to organic solvents in the air of beauty salons was measured from September 1, 2008 to September 30, 2008. A survey of symptoms that occurred due to exposure to these solvents was also performed. The results were as follows: questionnaires were collected and analyzed from a total of 36 subjects. Of these, 28(77.8%) were female and 8(22.2%) were male. The mean age was 29.08. The mean working period was 7.13 years. Sixteen subjects attended programs at universities while 11 went to beauty schools for vocational education. When testing the concentration of organic solvents in the air of beauty salons, the highest value found was Isopropyl alcohol 511.85 ppb followed by butyl acetate, toluene, acetone, xylene, ethyl benzene, styrene, and chlorobenzene. A logistic regression analysis was performed as follows: the point of each factor was the dependent variable while sex, age, drinking, smoking, educational level, work experience, hairdresser's license, and organic solvents were the independent variables. Statistically significant difference (p<0.05) was shown in the hairdresser's license among Factor 1 and in Xylene among Factor 2; however, difference was not shown in the other variables.

조제 첨가 음이온 발포제의 거품 효율 (Foaming Efficiency of Anion Foaming Agent Solution to Add Dyeing Assistants)

  • 김공주;박병기;조은진;김지주;이재덕
    • 한국염색가공학회지
    • /
    • 제4권3호
    • /
    • pp.82-90
    • /
    • 1992
  • To optimize the foam dyeing procedures for polyester and polyester/nylon blended non-woven fabrics, the effects of organic solvents and surfactants were investigated by measuring the foam heights and surface tensions of the foam dyeing solution. The results of the experiments can be summarized as follows: 1) Organic solvents and surfactants (sodium lauryl sulphate: SLS) solution lower the surface tension (ST) of the water, but ST lowering rate of SLS solution is greater than that of solvents. For a 0.25% SLS solution, the minimum surface tension was 30.3 dyne/cm, which is nearly the same value for organic solvents. 2) For 0.25% SLS solutions, additional adding of a 4.0% organic solvent makes the foam height (FH) be its maximum. 3) At 0.6 g/ι dye concentration, incorporation of 0.4% SLS makes the surface tension of the foam solution be its minimum. The foam height did not show any trend due to the dye type. 4) The effect of foam stabilizers (sodium alginate (Alg-Na) and hydroxy ethyl cellulose (HEC)) were also investigated. The foam height of the foaming solution with HEC was greater than that with Alg-Na. The foam stability of the foaming solution with Alg-Na was better than that with HEC.

  • PDF

특수 건강진단기관의 유기용제 분석 외부정도관리 실태 (The Status of Analytical External Quality Assurance Program of Organic Solvents for the Special Health Examination Laboratories)

  • 박관식;이미영;김종호
    • 대한임상검사과학회지
    • /
    • 제42권1호
    • /
    • pp.16-21
    • /
    • 2010
  • It has been well known that organic industrial solvents such as toluene, xylene and styrene are environmental health hazards causing occupational diseases to workers. The detection of biological metabolites of toluene, xylene and styrene in blood, urine, breast milk, saliva, and hair of workers exposed to these organic industrial solvents is a useful tool for assessing the amount of organic industrial solvents. Therefor, the external analytical quality assurance program is extremely important work for increasing reliability of the data analyzed in the special health examination laboratory. We evaluated the results of analysis by Korean analytical quality assurance program from the second half 2007 to the first half 2009. The number of participants for analytical quality assurance program for both mandatory item and one of optional items, hippuric acid and methylhippuric acid were 116-122, 116-122 and 105-115 laboratories, respectively. The proficient rate of the special health examination laboratories analyzed both mandatory item and optional item, hippuric acid and methylhippuric acid were 92-98%, 92-98% and 96-98%, respectively. We can conclude from our data that the analytical quality assurance program is a essential tool for improvement of reliability on the data analyzed in the special health examination laboratories.

  • PDF

유기용매 내성 세균과 이용가능성 (Solvent Tolerant Bacteria and Their Potential Use)

  • 주우홍
    • 생명과학회지
    • /
    • 제25권12호
    • /
    • pp.1458-1469
    • /
    • 2015
  • 유기용매 내성 세균의 첫 분리 보고 이후 다수의 유기용매 내성 세균들이 토양 폐수 심지어 심해 등 모든 환경에서 분리 보고되고 있다. 대부분의 유기용매 내성 세균은 그람음성세균으로 이는 그람음성 세균이 그람양성 세균 보다 유전적으로 더 내성을 보이기 때문이다. 유기용매 내성 기전은 유기용매 내성 그람음성 세균을 주로 사용하여 집중적으로 구명되어왔다. 유기용매 내성 그람양성 세균의 유기용매 내성 기전은 비교적 최근 연구에서 발견되고 있다. 유기용매는 용매에 따라 다른 독성을 보이며 유기용매 내성세균의 유기용매 내성 수준은 종과 균주에 의존적으로 매우 변화가 심하다. 그러므로 유기용매 내성세균은 다양한 변인과 다유전자에 의한 적응 전략에 의하여 용매독성과 싸우며 용매 스트레스에 적응할 수 있다. 그들은 세포형태 및 세포 행동에서의 변화, 세포표층의 수식, 세포막 적응, 용매 배출 펌프, 샤페론 그리고 항산화 반응 등의 기전을 통하여 유기용매의 과량의 농도에서도 생존할 수 있다. 본 총설에서는 대표적인 유기용매 내성 세균, 유기용매 내성 세균에서의 유기용매에의 적응 및 내성 전략들 나아가 그들의 산업적 및 환경공학적인 잠재적인 영향에 대하여 개관하고자 한다.