• Title/Summary/Keyword: organic pollution load

Search Result 67, Processing Time 0.028 seconds

Analysis of Water Quality Improvement Effect by Securing Water Quality Characteristics and Flow Rate in the Geumho River (금호강 수질특성 및 유량확보에 따른 수질개선 효과 분석)

  • Kwak, Insoo;Choi, Boram;Jeon, Hyeryn;Kim, Sunae;Bae, Jaehyeong;Kim, Shin;Kim, Jungmin
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.6
    • /
    • pp.414-429
    • /
    • 2020
  • For the management of rivers, the target water quality is set by establishing the total amount of water pollution and water environment basic plan. For Geumho river T-P has achieved the target water quality, but for BOD, COD, TOC the target water quality of the water environment basic plan has been exceed for the past five years. Therefore, the flow rate for satisfying the target water quality was simulated by analyzing the load, load density, and pollution contribution rate of the Geumho river using BOD, COD, TOC and by utilizing QUAL-MEV a one-dimensional water quality model. According to the analysis of the load, the BOD, COD and TOC all showed the highest levels at the Geumho C point at 9,832.2 kg/day 20,656.6 kg/day, and 15,545.1 kg/day. The load density was highest at 9.47 kg/day/㎢, 37.55 kg/day/㎢, 30.20 kg/day/㎢, and 17.19 kg/day/㎢, 39.14 kg/day/㎢ in Dalseocheon stream during the wet seasons and dry seasons. Pollution contribution rate was highest at about 25 percent for Palgeocheon stream during the wet season and about 50 percent for Dalseocheon stream during the dry season. In addition, the correlation analysis between organic materials showed in the main stream and tributaty of the Geumho river that COD-TOC was 0.8 or higherthan BOD-COD and BOD-TOC in both the wet seasons and dry seasons. And after surveying the total amount of water pollution and the target quality of the water environment basic plan at Geumho C, it was analyzed that an additional flow tate of 14 times and 22 times was needed as of April 2019 (3.46 ㎥/sec).

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

Reduction of Pollutant Load by Small Pond in a Rice Paddy Applied with Pig Manure Compost (돈분퇴비가 시용된 논의 양분유출 저감을 위한 저류지 효과)

  • Kim, Min-Kyeong;Kim, Myung-Hyun;Choi, Soon-Kun;Cho, Kwang-Jin;Hong, Seong-Chang;Jung, Goo-Bok;So, Kyu-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.21-27
    • /
    • 2014
  • Pig slurry has been considered as environmental waste to be treated in an appropriate manner. Moreover, water-born pollution loads by agricultural non-point source(NPS) pollution are expected to become intensified due to ongoing precipitation change. This study was conducted to develop a best management practice to reduce NPS pollution load by agricultural activity with pig manure compost. An eco-friendly way, small drainage pond, was suggested in this study to avoid direct drainage of agricultural runoffs and eventually reduce the amount of pollutants discharged into the surrounding aqua-environment. A small pond($12m^2$) was constructed at the corner of a rice paddy field($17,15m^2$) located in Suwon, Korea. Water was allowed to drain only via a small drainage pond. Sampling was repeatedly made at two locations, one from an entrance and the other from an exit of a pond, during the rice cultivation period(May to October, 2013). Generally, sampling was made only when runoff water drained through a pond, such as during and/or after rain(irrigation). The water quality analysis showed that all quality parameters(SS, $COD_{Mn}$, T-N, and T-P) were improved as water passed through the pond. The amount of runoff water was reduced by 67.8%. Suspended solids and $COD_{Mn}$ concentrations were reduced by 79.8% and 71.9%, respectively. In case of T-N and T-P amounts, the reduction rates were 73.6% and 74.9%, respectively. Our data implies that agricultural NPS pollution from rice paddy fields with pig manure-based fertilizer can be effectively managed when an appropriate drainage water management practice is imposed.

Characteristics of Water Quality Change of Urban River according to Installation of Interceptors and Wastewater Treatment Plant (차집관로와 하수처리시설의 설치에 따른 도시하천의 수질변화 특성)

  • Zhou, Juan Juan;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.813-820
    • /
    • 2014
  • In this study, the characteristics of water quality change of the three streams in Daejeon were analyzed according to the expanded installation of interceptors and wastewater treatment plant (WTP). Gabcheon 5 (Singu Bridge) location showed the maximum difference of the highest and lowest concentrations in the last decade. However, the recent water quality of this location was worse than other locations, because of the impact of the effluent from the WTP. In the upstream of the WTP, the Daejeon stream was relatively better than the other locations in organic pollution reduction, and this was caused by the investment for the management of the interceptors in three streams of Daejeon. According to the water quality standard of the stream water quality, the recent water quality of the three streams in Daejeon was acceptable within them in the most of the water quality items, but because the total phosphorus concentration of the upstream such as Daejeon stream, Yudeng stream, Gabchen 3 location did not reach the standard values, a better management of the interceptor was required in the upstream of WTP than its downstream. The upstream of WTP also required a better management of the interceptor than the downstream. The operation and management of WTP was required a high efficiency because the water quality of the effluent from the WTP incurred an adverse effect to the target water quality in the location of the total water pollution load management system.

A Study on the Appropriateness as Organic Matters Indicator and the Distribution of Chemical Oxygen Demand and Total Organic Carbon in Masan Bay, Korea (마산만 해수 중 화학적산소요구량과 총유기탄소 분포 특성 및 유기물 지표로서의 적절성 검토)

  • PARK, MI-OK;LEE, YONG-WOO;CHO, SEONG-AH;KIM, HYE-MI;PARK, JUN-KUN;KIM, SUNG-GIL;KIM, SEONG-SOO;LEE, SUK MO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.2
    • /
    • pp.82-95
    • /
    • 2021
  • We investigated the temporal and spatial distribution characteristics of chemical oxygen demand (COD) and total organic carbon (TOC) in all 13 locations of Masan Bay from February to November in 2015. The COD and TOC contents were high during the June-August period when the pollution load increased. In particular, the concentrations of COD and TOC were about twice as high in the surface water as in the bottom water. In spatial distribution, the COD and TOC concentrations at the inner bay were about twice as high as those of the outer bay in Masan Bay. As a result of estimating the oxidation efficiency of COD from the surface layer of Masan Bay in 2015 based on the theoretical oxygen demand (TOD), it was at the level of about 23%. Due to the low oxidation efficiency of COD, there is a risk that the organic matter in Masan Bay will be somewhat underestimated. Therefore, for quantitative analysis of organic matter, COD and TOC analyses need to be combined.

Ecosystem Modelling for Improvement Summer Water Quality of Jinhae Bay in 2003 (2003년 하계 진해만 수질 개선을 위한 생태계 모델링)

  • Hong, Sok-Jin;Lee, Won-Chan;Jung, Rea-Hong;Oh, Hyun-Tek;Jang, Ju-Hyung;Goo, Jun-Ho;Kim, Dong-Myung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.2 s.29
    • /
    • pp.103-110
    • /
    • 2007
  • This study estirmted the appropriate pollutant load reduction from point sources in Jinhae Bay, Korea, using an eco system model. The results of COD values in the inner part of the bay obtained through the simulation by ecosystem model were greater than 3.0mg/L, and exceeded the limits of Korean Coastal Water Quality Grade III. Engineering countermeasures to reduce the $70\sim90%$ of all land based pollution load or organic and inorganic material loads from point sources by more than 50% were required to keep the COD levels below 2 mg/L. The reduction loads is 5,632kg/day of COD, 481kg/day of DIP and 7,991 kg/day of DIN in case of the reduction of both the organic and nutrients. The estimated environmental currying capacity of that case is 13,112kg/day of COD, 206kg/day of DIP and 3,425kg/day of DIN to keep the COD levels below 2mg/L.

  • PDF

A Study on the Material Circulation System of Ecovillage - Focused on the Cristalwaters Ecovillage in Australia - (생태마을의 물질순환체계에 관한 연구 - 호주 크리스탈워터스 생태마을을 중심으로 -)

  • Choi, Young-Ho;Shim, Woo-Gab
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.49-56
    • /
    • 2004
  • This study intends to propose the fundamentals of 'Ecovillage' design by researching into the cycle system of material of 'Crystalwaters' which is having been in charge of a leading role of GEN since 1996 (GEN was formed in 1996) as Ecovillage in Australia. First, to secure the water resources, we can store up rain and the water of valley, and dam. Second, we are able to use the natural filter apparatus, do tree-planting of roof to gain better quality of water. Third, it is to save the energy as supplying water. For it, we make the best of a gravity that is one of the cycle principle of water. Forth, to build a Dam can make a site of scenic beauty, do the role of recreation place and provide against emergencies (a fire, drought) as well as make a mild climate. Fifth, it can reduce the environment load because of sewage and garbage as making it compost. This is possible by treating biologically using composting apparatus of the dry or wet process. Sixth, it is to reduce the environmental pollution as to discharge seperating a recycable waste, an organic matter being able to make it compost. Finally, first of all, environmentally friendly inhabitant consciousness from lifestyle and production style plays an importent part for water cycle and the ecological cycle of waste and sewage.

The Runoff Characteristics of Non-point Pollution Sources in Industrial Complex(I): Focusing on the analysis of runoff water according to the initial rainfall of the C Industrial Complex (산업단지 비점오염원의 유출특성(I): C산업단지의 초기강우에 따른 유출수 분석을 중심으로)

  • Woo, Jae-Suk;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.1
    • /
    • pp.23-32
    • /
    • 2022
  • In this study, rainfall water outlet water quality monitoring was performed on the C industrial complex to evaluate the characteristics of non-point pollutant runoff from the industrial complex during rainfall and to use it as basic data for calculating the load and unit of non-point pollutant. As a result of the IETD analysis, it was selected as a representative rainfall event for simulating non-point pollutants when the rainfall duration was about 21 hours and the rainfall was 26.44mm. Also as a result of monitoring the flow and water quality survey, the first rainfall was 12.2 mm, the rainfall duration was 12 hr, the number of preceding dry days was 3 days, the second rainfall was 22.1 mm, the rainfall duration was 12 hr, and the number of preceding dry days was 7 days.

A Study on Combustion and Emission Characteristics of Diesel Generator Fuelled with Coffee Ground Pyrolysis Oil (커피박 열분해유를 연료로 사용하는 디젤 발전기의 연소 및 배출물 특성에 관한 연구)

  • PARK, JUNHA;LEE, SEOKHWAN;KANG, KERNYONG;LEE, JINWOOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.567-577
    • /
    • 2019
  • Due to the depletion of fossil fuels and environmental pollution, demand for alternative energy is gradually increasing. Among the various methods, a method to convert biomass into alternative fuel has been proposed. The bio-fuel obtained from biomass through pyrolysis process is called pyrolysis oil (PO) or bio-oil. Because PO is difficult to use directly in conventional engines due to its poor fuel properties, various methods have been proposed to upgrade pyrolysis-oil. The simplest approach is to mix it with conventional fossil fuels. However, due to their different polarity of PO and fossil fuel, direct mixing is impossible. To resolve this problem, emulsification of two fuels with a proper surfactant was proposed, but it costs additional time and cost. Alternatively, the use of alcohol fuels as an organic solvent significantly improve the fuel properties such as fuel stability, calorific value and viscosity. In this study, blends of diesel, n-butanol, and coffee ground pyrolysis oil (CGPO) which is one of the promising PO, was applied to diesel generator. Combustion and emissions characteristics of blended fuels were investigated under the entire load range. Experimental results show that ignition delay is similar to that of diesel at high load. Although, hydrocarbon and carbon monoxide emissions are comparable to diesel, significant reduction of nitrogen oxides and particulate matter emissions were observed.

Analysis of the petrological characteristics and deterioration phenomena of the rocks consisting the Gwangtonggyo(bridge) on the Cheonggyecheon(river) (광통교 구성암석의 석질 및 훼손양상 분석 연구)

  • Lee, Sang Hun
    • Journal of Conservation Science
    • /
    • v.17 s.17
    • /
    • pp.39-56
    • /
    • 2005
  • The Gwangtonggyo(bridge) on the Cheonggyecheon(river) is mainly composed of biotite granite with coarse grain. The rock consists mainly of quartz, plagioclase, microcline, orthoclase and biotite with lesser amount of muscovite, sericite and chlorite. Muscovite and sericite may be formed from feldspars and chlorite from biotite by alteration(including weathering). These rocks are relatively deteriorated by weathering, polluted water running the river and heavy traffic. The main phenomena of damages are surface exfoliation, grain separation, deceleration, pollution of organic and heavy chemical elements, cracks and breakage. These phenomena have been analyzed by polarized microscope, XRD and SEM/EDX. The analyzed results show organic pollution and secondarily formed gypsum and apatite on the rock surface and micro-pores. NaCl and $CaCO_3$ as rock salt and calcite probably may be formed secondarily in some points. Also heavy chemical elements such as Cr, Pb, Pd, W, La, Zn and Nd are polluted in some samples. The contacts between rocks are generally breakdown in small scale or cracks are developed due to mainly load and vibration shock of heavy traffic.

  • PDF