• 제목/요약/키워드: orbital fractures

검색결과 124건 처리시간 0.028초

안와파열골절 환자에서 중증 외상성 안구내 손상 발생과 연관인자 분석 (Severe Traumatic Intraocular Injuries Related to Blowout Fractures)

  • 신재훈;이미진;박성수;정원준;유연호
    • Journal of Trauma and Injury
    • /
    • 제22권1호
    • /
    • pp.97-102
    • /
    • 2009
  • Purpose: Blunt trauma can cause a wide range of ocular injuries. This study was performed to describe the prevalence of severe intraocular injuries (SIOI) and their correlation with the severity of blunt orbital trauma. Methods: We retrospectively analyzed 117 eyes of 107 patients with orbital wall fractures who visited the emergency room at Konyang University Hospital from July 2006 to June 2008. Clinical features such as age, sex, causes of injury, revised trauma score (RTS), type of orbital wall fractures were recorded. The patients were divided into two groups: blowout fracture with severe intraocular injuries (SIOI) and blowout fracture without SIOI. We compared the clinical and the injury-related characteristics between two groups and analyzed the SIOS-related factors. Results: Among the 107 patients (117 eyes) with blowout fractures, 29 (27.1%) patients with 32 eyes (25.6%) had complicated severe intraocular injuries. Retrobulbar hemorrhage (14.5%), hyphema (13.7%), traumatic optic nerve injury (4.3%), and sustained loss of visual acuity (4.3%) were the most common SIOI disorders. A logistic regression analysis revealed that loss of visual acuity (odds ratio = 4.75) and eyeball motility disorder (odds ratio=7.61) were significantly associated with SIOS. Conclusion: We suggest that blowout fracture patients with loss of visual acuity or eyeball motility disorder are mostly likely to have severe intraocular injuries, so they need an ophthalmologic evaluation immediately.

Delayed Orbital Hemorrhage around Alloplastic Implants after Blowout Fracture Reduction

  • Ryu, Yong Ah;Park, Jae Beom;Kyung, Hyun Woo;Song, Seung Han;Kang, Nak Heon
    • 대한두개안면성형외과학회지
    • /
    • 제16권1호
    • /
    • pp.35-38
    • /
    • 2015
  • Alloplastic implants have been used to repair orbital wall fractures in most cases. Orbital hemorrhage is a rare complication of these implants and has been reported rarely in Korea. The purpose of this article is to report a late complication case focusing on their etiology and management. A 20-year-old male patient underwent open reduction with Medpor (porous polyethylene) insertion for bilateral orbital floor fractures. The initial symptom occurred with proptosis in the right side as well as vertical dystopia, which had started 4 days earlier, 8 months after surgery. Any trauma history after the surgery was not present. We performed an exploration and removal of hematoma with Medpor titanium meshed alloplastic implant. A case of delayed orbital hematoma following alloplastic implant insertion was identified. It occurred within the pseudocapsule of the implant. One week after surgery, overall symptoms improved successfully, and no complications were reported during the 11-month follow-up period. Although rare, orbital hemorrhage is a potential complication of alloplastic orbital floor implants, which may present many years after surgery. As in the case presented, delayed hematoma should be included in the differential diagnosis of late proptosis or orbital dystopia.

내시경을 이용한 비강내 접근법과 속눈썹밑 절개를 동시에 이용한 안와내벽 재건술 (Two Portal Approach(Endoscopic Transnasal and Subciliary) in Medial Orbital Wall Fracture)

  • 장현;동은상;원창훈;윤을식
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.552-556
    • /
    • 2006
  • Purpose: As the use of computed tomographic scanning spread, the diagnosis of blow-out fractures of the medial orbital wall increased. Conventionally, the surgery of blow-out fractures in medial orbital wall was performed by various approaches with external incision or endoscopic approach. Although the field of orbital surgery has progressed significantly during the last decade, accurate realignment and replacement of component is difficult due to lack of visualization of the fracture site, blind dissection of the orbital wall, and difficulty in insertion of implant. In order to overcome these shortcomings, we explored the use of endoscopic transnasal approach together with subciliary approach. Methods: The entrapped periorbital tissues in the ethmoid sinus were completely reduced endoscopically, and the bone defect of medial orbital wall was reconstructed with $Medpor^{(R)}$ insertion via subciliary approach. This technique was applied to 13 patients who had medial orbital wall fracture. Results: The patients were followed-up for 3 to 24 months with an average of 9 months. The postoperative courses were satisfactory in all cases. Conclusion: The conjunction of endoscopic transnasal and subciliary approach technique seems to produce good results in medial orbital wall fracture.

Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

  • Cha, Jong Hyun;Moon, Myeong Ho;Lee, Yong Hae;Koh, In Chang;Kim, Kyu Nam;Kim, Chang Gyun;Kim, Hoon
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.26-33
    • /
    • 2017
  • Background The purpose of this study was to assess the correlation between the 2-dimensional (2D) extent of orbital defects and the 3-dimensional (3D) volume of herniated orbital content in patients with an orbital wall fracture. Methods This retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital wall fracture. They were classified into 2 groups depending on whether the fracture involved the inferior wall (group I, n=30) or the medial wall (group M, n=30). The 2D area of the orbital defect was calculated using the conventional formula. The 2D extent of the orbital defect and the 3D volume of herniated orbital content were measured with 3D image processing software. Statistical analysis was performed to evaluate the correlations between the 2D and 3D parameters. Results Varying degrees of positive correlation were found between the 2D extent of the orbital defects and the 3D herniated orbital volume in both groups (Pearson correlation coefficient, 0.568-0.788; $R^2=32.2%-62.1%$). Conclusions Both the calculated and measured 2D extent of the orbital defects showed a positive correlation with the 3D herniated orbital volume in orbital wall fractures. However, a relatively large volume of herniation (>$0.9cm^3$) occurred not infrequently despite the presence of a small orbital defect (<$1.9cm^2$). Therefore, estimating the 3D volume of the herniated content in addition to the 2D orbital defect would be helpful for determining whether surgery is indicated and ensuring adequate surgical outcomes.

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

  • Choi, Tae Joon;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • 제43권1호
    • /
    • pp.84-87
    • /
    • 2016
  • Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

Usefulness of indirect open reduction via a transconjunctival approach for the treatment of nasal bone fracture associated with orbital blowout fracture

  • Kim, Tae Ho;Kang, Seok Joo;Jeon, Seong Pin;Yun, Ji Young;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.102-107
    • /
    • 2018
  • Background: Nasal fracture and orbital blowout fracture often occur concurrently in cases of midface blunt trauma. Generally, these multiple fractures treatment is surgery, and typically, the nasal bone and orbit are operated on separately. However, we have found that utilizing a transconjunctival approach in patients with concurrent nasal bone fracture and orbital blowout fracture is a useful method. Methods: The participants in the present study included 33 patients who visited the Plastic Surgery outpatient department between March 2014 and March 2017 and underwent surgery for nasal fracture and orbital blowout fracture. We assessed patients' and doctors' satisfaction with surgical outcomes after indirect open reduction via a transconjunctival approach for the treatment of nasal bone fracture with associated orbital blowout fracture. Results: According to the satisfaction scores, both patients and doctors were satisfied with transconjunctival approach. Conclusion: We presented here that our method enables simultaneous operation of nasal fracture accompanied by orbital blowout fracture, rather than treating the two fractures separately, and it allows precise reduction of the nasal fracture by direct visualization of the fracture site without any additional incisions or difficult surgical techniques. Also, by preventing the use of excessive force during reduction, this method can minimize damage to the nasal mucosa, thereby reducing the incidence of nasal bleeding.

Mapping the Posterior Ledge and Optic Foramen in Orbital Floor Blowout Fractures

  • Yu Cong Wong;Doreen S.L. Goh;Celine S.Y. Yoong;Cowan Ho;Elijah Z. Cai;Angela Hing;Hanjing Lee;Vigneswaran Nallathamby;Yan L. Yap;Jane Lim;Sundar Gangadhara;Thiam C. Lim
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.370-376
    • /
    • 2023
  • Background The posterior ledge (PL) is a vital structure that supports the implant posteriorly during orbital floor reconstruction. This study describes a technique for mapping the PL in relation to the infraorbital margin (IM) in patients with orbital floor blowout fractures. This study establishes the location of the optic foramen in relation to the PL. Methods Facial computed tomography (FCT) scans of 67 consecutive patients with isolated orbital floor blowout fractures were analyzed using Osirix. Planes of reference for orbital fractures, a standardized technique for performing measurements on FCT, was used. Viewed coronally, the orbit was divided into seven equal sagittal slices (L1 laterally to L7 medially) with reference to the midorbital plane. The distances of PL from IM and location of optic foramen were determined. Results The greatest distance to PL is found at L5 (median: 30.1 mm, range: 13.5-37.1 mm). The median and ranges for each slice are as follows: L1 (median: 0.0 mm, range: 0.0-19.9 mm), L2 (median: 0.0 mm, range: 0.0-21.5 mm), L3 (median: 15.8 mm, range: 0.0-31.7 mm), L4 (median: 26.1 mm, range: 0.0-34.0 mm), L5 (median: 30.1 mm, range: 13.5-37.1 mm), L6 (median: 29.0 mm, range: 0.0-36.3 mm), L7 (median: 20.8 mm, range: 0.0-39.2 mm). The median distance of the optic foramen from IM is 43.7 mm (range: 37.0- 49.1) at L7.

얼굴뼈 CT 계측 모형을 이용한 안와벽골절의 재건 (Orbital Wall Reconstruction by Copying a Template (defect model) from the Facial CT in Blow-out Fracture)

  • 김재근;유선혜;황건;황진희
    • 대한두개안면성형외과학회지
    • /
    • 제10권2호
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: Recently, orbital wall fracture is common injuries in the face. Facial CT is essential for the accurate diagnosis and appropriate treatment to reconstruct of the orbital wall. The objective of this study was to report the method for accurate measurement of area and shape of the bony defect in the blow-out fractures using facial CT in prior to surgery. Methods: The authors experienced 46 cases of orbital wall fractures and examined for diplopia, sensory disturbance in the area of distribution of the infraorbital nerve, and enophthalmos in the preoperation and followed 1 months after surgery, from August 2007 to May 2008. Bony defect was predicted by measuring continuous defect size from 3 mm interval facial CT. Copying from the defect model (template), we reconstructed orbital wall with resorbable sheet (Inion $CPS^{(R)}$ Inion Oy, Tampere, Finland). Results: One months after surgery using this method, 26 (100%) of the 26 patients improved in the diplopia and sensory disturbance in the area of distribution of the infraorbital nerve. Also 8 (72.7%) of the 11 patients had enophthalmos took favorable turn. Conclusion: This accurate and time-saving method is practicable for determining the location, shape and size of the bony defect. Using this method, we can reconstruct orbital wall fracture fastly and precisely.

Comparison of Absorbable Mesh Plate versus Titanium-Dynamic Mesh Plate in Reconstruction of Blow-Out Fracture: An Analysis of Long-Term Outcomes

  • Baek, Woon Il;Kim, Han Koo;Kim, Woo Seob;Bae, Tae Hui
    • Archives of Plastic Surgery
    • /
    • 제41권4호
    • /
    • pp.355-361
    • /
    • 2014
  • Background A blow-out fracture is one of the most common facial injuries in midface trauma. Orbital wall reconstruction is extremely important because it can cause various functional and aesthetic sequelae. Although many materials are available, there are no uniformly accepted guidelines regarding material selection for orbital wall reconstruction. Methods From January 2007 to August 2012, a total of 78 patients with blow-out fractures were analyzed. 36 patients received absorbable mesh plates, and 42 patients received titanium-dynamic mesh plates. Both groups were retrospectively evaluated for therapeutic efficacy and safety according to the incidence of three different complications: enophthalmos, extraocular movement impairment, and diplopia. Results For all groups (inferior wall fracture group, medial wall fractrue group, and combined inferomedial wall fracture group), there were improvements in the incidence of each complication regardless of implant types. Moreover, a significant improvement of enophthalmos occurred for both types of implants in group 1 (inferior wall fracture group). However, we found no statistically significant differences of efficacy or complication rate in every groups between both implant types. Conclusions Both types of implants showed good results without significant differences in long-term follow up, even though we expected the higher recurrent enophthalmos rate in patients with absorbable plate. In conclusion, both types seem to be equally effective and safe for orbital wall reconstruction. In particular, both implant types significantly improve the incidence of enophthalmos in cases of inferior orbital wall fractures.

경중도 안와 내벽 골절의 수술 시 흉터 최소화를 위한 변형된 직접 W-절개법과 실리콘판을 이용한 재건 (Modified Direct W-incision with Silicone Sheet to Minimize Operation Scar in Reconstruction of Mild to Moderate Symptomatic Medial Orbital Wall Fracture)

  • 정재아;공정식;김양우;강소라
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.30-35
    • /
    • 2013
  • Background: For reconstruction of the mild to moderate medial orbital wall fractures, various surgical approaches have been used. Prior existing W-shaped incision was a direct local approach through a 3 cm incision on the superior medial orbital area with a titanium mesh implant. In this study, the authors modified W-shaped incision and reconstructed the defect with silastic sheet to improve the result and the postoperative scar. Methods: This study included 20 patients who had mild to moderate size of medial wall defect and therefore relatively suitable for reconstruction with silastic sheets from July, 2009 to December, 2011. A modified W-shaped skin incision approximately 1.2 to 1.5 cm in length was made along the superior medial orbital rim from approximately 1 cm medial to the medial canthus to the lower border of the medial eyebrow. The angles of the limbs of the W ranged from 150 to 160 degrees. Results: By using soft flexible silastic sheet, the authors reduced the incision from 3 to 1.5 cm, and by widening the angle of the W limbs, scars were more effectively hided in the relaxed skin tension line. Scar assessment was done with modified patient and observer scar assessment scale and mean score from patients was 2.08 and mean score from observers was 2.12. Conclusion: Although this method will not be suitable for every case, it can be a consistent method to obtain the surgical goal in treatment of mild to moderate blowout fractures of the medial orbital wall.