• Title/Summary/Keyword: orbital correction

Search Result 61, Processing Time 0.028 seconds

Measurement of Orbit using Standardized Processing of CT Scan

  • Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose Surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these surgeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable reationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. Method Author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Results The method was allowed to evaluate inter-dacryon distance, inter-centroid distance, movement of the medial orbital wall, movement of the lateral orbital wall, alteration of thickness of the lateral periorbital fat as indicator of movement of the orbital wall and orbit in the patient with congenital periorbital anomaly and postoperative periorbital surgery. The goal of surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these sugeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable relationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. In this report, author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Conclusion The method suggested is objective and accurate method in measurement of the orbital contents. It takes time and is not easy to do, however, this kind of measurement for fine structures will be more easily available in near future.

Enhancement of Ionospheric Correction Method Based on Multiple Aperture Interferometry (멀티간섭기법에 기반한 이온왜곡 보정기법의 보완)

  • Lee, Won-Jin;Jung, Hyung-Sup;Chae, Sung-Ho;Baek, Wonkyung
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.2
    • /
    • pp.101-110
    • /
    • 2015
  • Synthetic Aperture Radar Interferometry (InSAR) is affected by various noise source such as atmospheric artifact, orbital error, processing noise etc.. Especially, one of the dominant noise source for long-wave SAR system, such as ALOS PALSAR (L-band SAR satellite) is the ionosphere effect because phase delays on radar pulse through the ionosphere are proportional to the radar wavelength. To avoid misinterpret of phase signal in the interferogram, it is necessary to detect and correct ionospheric errors. Recently, a MAI (Multipler Aperture SAR Interferometry) based ionospheric correction method has been proposed and considered one of the effective method to reduce phase errors by ionospheric effect. In this paper, we introduce the MAI-based method for ionospheric correction. Moreover we propose an efficient method that apply the method over non-coherent area using directional filter. Finally, we apply the proposed method to the ALOS PALSAR pairs, which include the west sea coast region in Korea. A polynomial fitting method, which is frequently adopted in InSAR processing, has been applied for the mitigation of phase distortion by the orbital error. However, the interferogram still has low frequency of Sin pattern along the azimuth direction. In contrast, after we applied the proposed method for ionospheric correction, the low frequency pattern is mitigated and the profile results has stable phase variation values within ${\pm}1rad$. Our results show that this method provides a promising way to correct orbital and ionospheric artifact and would be important technique to improve the accuracy and the availability for L-band or P-band systems.

Transconjunctival capsulopalpebral fascia fixation for the correction of orbital fat buldging (결막접근을 통한 근막초 고정법(capsulopalpebral fascia fixation)을 이용한 안와지방 돌출의 교정)

  • Lee, Eun Jung
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.194-199
    • /
    • 2009
  • Purpose: The orbital fat buldging may cause irregular contour of lower eyelid, which is not youthful appearance. The conventional method of fat excision may cause the eyeball to move backward and downward, making enopthalmia is inevitable. The transcutaneous approach to reach the orbital septum can increase the risks of scleral show resulting from scarification at the level of the septum orbicularis junction and damaging the vertical motor branches of the preseptal orbicularis oculi muscle of the lower eyelid. Method: From July 2007 to March 2008, total of 21 patients underwent transconjunctival capsulopapebral fascia fixation procedure. In 8 patients, the herniated fat pad of the lower eyelid was relocated back into the orbit without external skin excision using capsulopalpebral fascia fixation. But in 13 patients, excision of redundant skin of the lower eyelid was performed using pinching technique, not involving orbicularis oculi muslce. In 5 patients, lateral canthotomy was done bilaterally for good visual field. In 6 patients, lateral canthopexy was also combined to correct loosening of lower eyelid. Results: Most of the patients were satisfied after at least 5 months of follow up. No patient showed scleral show. But 2 patients complained of undercorrection slightly, without secondary operation in 1 patient and re - capsulopalpebral fascia fixtation through transconjunctival approach in another patient. Conclusion: Orbital fat repositioning using transconjunctival capsulopalpebral fascia fixation is a good procedure to show youthful appearance without increasing the risk of scleral show and also showed fast recovery compared to the conventional transcutaneous approach.

Density Functional Theoretical Study on Intermolecular Interactions of 3,6-Dihydrazino-1,2,4,5-tetrazine Dimers

  • Hu, Yin;Ma, Hai-Xia;Li, Jun-Feng;Gao, Rong;Song, Ji-Rong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2897-2902
    • /
    • 2010
  • Seven fully optimized geometries of 3,6-dihydrazino-1,2,4,5-tetrazine (DHT) dimers have been obtained with density functional theory (DFT) method at the B3LYP/$6-311++G^{**}$ level. The intermolecular interaction energy was calculated with zero point energy (ZPE) correction and basis set superposition error (BSSE) correction. The greatest corrected intermolecular interaction energy of the dimers is $-23.69\;kJ{\cdot}mol^{-1}$. Natural bond orbital (NBO) analysis is performed to reveal the origin of the interaction. Based on the vibrational analysis, the changes of thermodynamic properties from the monomers to dimer with the temperature ranging from 200.0 K to 800.0 K have been obtained using the statistical thermodynamic method. It was found that the hydrogen bonds dominantly contribute to the dimers, while the binding energies are not only determined by hydrogen bonding. The dimerization process can not occur spontaneously at given temperatures.

The Correction of Lower Palpebral Bulge & Tear trough Groove by Repositioning of Orbicularis Oculi Muscle, Orbital Septum & Orbital Fat (눈둘레근육, 눈확사이막 및 지방재배치에 의한 눈꺼풀자루와 눈물받이고랑의 교정)

  • Jin, Eui Sang;Jung, Jae Hak;Kim, Young Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.32 no.3
    • /
    • pp.304-310
    • /
    • 2005
  • Bulging of the lower eyelid & tear trough groove is regarded as a sign of aging. In the past, the surgical excision of the fat pad has been the mainstray of the management of lower palpebral bag in cosmetic blepharoplasty, Recently, fat pad sliding method has been introduced to make more attractive lower eyelids. We used the fat pad for covering the hollowness of the lower eye lid. And we use redundant fat pad for filling & augmentation of the lower eye lid by reflexion. Redraping of the orbicularis arc, with its accompanying midfacial fat repositioning, anatomically restores the cheek and lower lid to make more youthful contour. By redraping and fixing the orbicularis arc on the medial surface of the orbital rim, it becomes a more attractive midface and may prevent of ectropion. From August, 2002 to July, 2004 in correction of lower palpebral bulge & tear trough groove, these two technique were performed in 42 consecutive individuals (84 lower eyelid) for two-year period. Follow up ranged from 3 to 15 months. (an average of 9 months) Palpebral bulge & tear trough groove were corrected and obtained a youthful midface. Complication was rare. The advantages of these techniques are that: prevent in of secondary palpebral bulge and irregularity of lower eyelid by using of reflexed fat fad; prevent in of ectropion. Thus an attractive midface is obtained by redraping of orbicularis arc.

Correction of High Fold without Skin Excision (피부 제거 없이 시행한 높은 쌍꺼풀의 교정)

  • Oh, Heung Chan;Yoon, Dong Ju;Kang, Cheol Uk;Choi, Chi Won;Choi, Soo Jong;Bae, Yong Chan
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.649-653
    • /
    • 2009
  • Purpose: Double - eyelid operation is one of the most common cosmetic operations among Korean patients. In such operations, however, the complexity of and individual differences in the patients' anatomical structures may cause various complications, such as asymmetry, retraction of the eyelid, and the occurrence of a high fold. A high fold occurs frequently, and its correction is not very simple. Many methods have been developed to correct it, and among these, the operation involving the excision of the skin between the previous double - eyelid line and the new double - eyelid line is usually selected by plastic surgeons. In many cases, however, patients have insufficient eyelid skins for this operation. In this study, the authors introduce an operation procedure for high - fold correction that does not involve skin excision Methods: From June 2005 to June 2009, 246 cases were treated with this procedure. After the incision of the new double - eyelid line, dissection was done between the previous scar tissue and the levator aponeurosis. Then the orbital septum, orbital fat or the retro - orbicularis oculi fat was slid down and sutured with a tarsal plate. Such sutures were repeated at four to five points, including the lateral and medial limbus, to prevent the reattachment of the previous scar and to create a new double - eyelid line at the end of the orbital septum. Results: Most of the high - fold patients were satisfied with the procedure described above. Their previous scar was hidden under the new double - eyelid line after the operation. In the six cases, the scar was visible in the patients who had a very high and deep inner line. As such, scar revision was undertaken three months after the operation. It is known that scar revision is also required after an operation involving skin excision in the case of a very high inner - eyelid line. Conclusion: This method is an appropriative procedure for high - fold correction for patients who have insufficient upper - eyelid skin.

Analysis of Induced Magnetic Field Bias in LEO Satellites Using Orbital Geometry-based Bias Estimation Algorithm (궤도 기하학 기반 바이어스 추정기법을 이용한 저궤도 위성의 유도자기장 바이어스 분석)

  • Lee, S.H.;Yong, K.L.;Choi, H.T.;Oh, S.H.;Yim, J.R.;Kim, Y.B.;Seo, H.H.;Lee, H.J.
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1126-1131
    • /
    • 2008
  • This paper applies the Orbital Geometry-based Bias Estimation Algorithm to the magnetometer measurement data of KOMPSAT-1 and 2 and analyzes the induced magnetic field bias caused by the solar panels and electronics boxes in spacecraft bus. This paper reveals that the estimation and correction of the induced magnetic field bias copes with the aging process of magnetometer and makes it possible to carry on the satellite mission by extending its lifetime.

SECONDARY REPAIR OF LATE ENOPHTHALMOS WITH CALVARIAL BONE GRAFTS AROUND INTRAORBITAL CONTENT -REPORT OF 2 CASES- (안와주위에 두개골이식을 통한 안구함몰의 이차적 성형재건 치험례)

  • Kim, Sung-Gil
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.373-378
    • /
    • 1998
  • In the midfacial fracture, the orbital region presents many additional complication unique to the orbit. Among them are ectropion, entropion, lid ptosis, injury to the lacrimal apparatus, diplopia or the late development of enophthalmos. The residual problem confronting the surgen is usually enophthalmos or diplopia. Enophthalmos becomes cosmetically obvious at 3mm and if more severe it can interfere with vision from obstruction by the orbital rim. In this clinical situation, many patients prefer the simpler intraorbital volume expansion to the more complex orbital osteotomy. In general, except in mild cases of enophthalmos, the procedure of choice is osteotomy and repositioning for zygoma fracture and volume augmentation for blow-out fracture. Late treatment is performed by volume augmentation based on the CT findings behind the axis of the globe. Inferiorly placed grafts elevate the globe, posterior superior grafts move the globe anterior and medially positioned grafts push the globe laterally. In this two cases, the patients who has stable orbitozygomatic rim, the use of calvarial bone grafts more than 3 areas around intraorbital content, we corrected late enophthalmos combined with diplopia. As result, the first patient had 2mm advance in exophthalmometric check with improvement of the diplopia gradually. The second patient had 1.5mm advance with correction of vertical ocular dystopia and cosmetically good results respectively.

  • PDF

Treatment of Severe Blepharoptosis after Blow Out Fracture (안와 파열골절 후 발생한 중증 안검하수의 치료)

  • Kim, Nam-Hun;Yang, Jeong-Yeol;Moon, Jae-Won;Kim, Gyu-Bo;Cheon, Ji-Seon
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.461-464
    • /
    • 2010
  • Purpose: Blepharoptosis can result from either congenital or acquired causes. Blow out fracture or facial bone fracture including blow out fracture can be one of the causes. Authors experienced 3 cases of severe blepharoptosis after blow out fracture treated only with observation after reduction of associated fracture. Methods: Reconstruction of orbital wall was conducted on all cases diagnosed as blow out fracture using 3 dimensional computed tomography, and conservative treatment was done on accompanying severe blepharoptosis. Results: At the time of injury, all cases showed severe blepharoptosis requiring frontalis muscle transfer for correction. But blepharoptosis was recovered in an average of 18 weeks without any surgical procedure except reconstruction of orbital wall. Conclusion: Once Blepharoptosis occurred after blow out fracture, thorough evaluation must be done at first. If definitive cause of blepahroptisis cannot be found as authors' cases, injury of oculomotor nerve may result in blepharoptosis. So, as for blepharoptosis after blow out fracture, conservative treatment following reconstruction of fractured orbital wall can be one of good management.

Electrochemical Studies on Heptamethine Cyanine Dyes

  • Kim, Young-Sung;Shin, Jong-Il;Park, Soo-Youl;Jun, Kun;Son, Young-A
    • Textile Coloration and Finishing
    • /
    • v.21 no.5
    • /
    • pp.35-40
    • /
    • 2009
  • Computational calculations of molecular orbital and electrochemical redox/oxidation potentials are of very importance to determine the compound properties. The energy levels of molecular orbital were calculated by the density function theory (DFT) with exchange correction functional of local density approximation (LSA) based on the Perdew-Wang (PWC) setting and cyclic voltammetry.