• Title/Summary/Keyword: oral temperature

Search Result 307, Processing Time 0.025 seconds

Toothbrush sterilizing effects of using microwave (Microwave를 이용한 칫솔 살균효과)

  • Ji, Yun-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.641-646
    • /
    • 2012
  • Objectives : The purpose of this study is to analyze the sterilizing effects of toothbrushes by administering bacteria into toothbrushes and reproducing the antibacterial effects using a microwave oven. Methods : The heads of four-row mid-strength toothbrushes were cut, put in a bacterial solution ($3{\times}10^9cells/ml$) for vortexing, and sterilized with microwaves for 0, 30, and 60 seconds. They were then moved into four tubes containing DW 10 ml and suspended in a vortex mixer for two minutes to separate bacteria from them. DW 9ml was added by 1ml of bacteria for dilution of $10{\sim}10^6$ times. It was then administered to the BHI agar plate by 0.1ml and cultured at $37^{\circ}C$ for 24 hours. Total number of bacteria adhered to a toothbrush was obtained by multiplying the number of colonies by the dilution factor. The experiment was done in the first, second, and third step, being repeated in a normal temperature drier ($23^{\circ}C$) after 5, 9 and 24 hours. Results : The results of the experiment revealed that the sterilizing effects were 95% or over. When toothbrushes were sterilized for 60 seconds, the number of colonies is about 11 after drying for 5 hours, 7 after drying for 9 hours and 2 after drying for 24 hours. The sterilizing effects reached 98% when the bacteria-administered toothbrush was sterilized for 1 minute after drying for 24 hours. Conclusions : The results demonstrated that toothbrush sterilizing by using microwave is a suitable way to prevent cross-contamination of toothbrushes by oral bacterial infection and thus easy to use at home. However, this study suggests that toothbrush sterilizing by using microwave should be limited within two times a week because the physical properties of toothbrush might be changed.

The study of recognition on cold and heat application of the adult (일반인의 냉온요법에 대한 인식 조사)

  • Kim Min-Jeong
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.3
    • /
    • pp.452-463
    • /
    • 1999
  • This study was performed to inquire into recognition of cold and heat application. The subjects in the study were 429 adults who were collected by disproportional quota sampling according to age, sex. The instrument was 36 questions that constitured closed questions and semiopened questions that encluded general characteristics, recognition of cold and heat applications. and what will you do when requested cold and heat applications on abdomial and perineal areas. Data were collected from september 25 to October 25, 1998. Data was analysed by SPSS/win, into frequency, Pearson correlation, t-test, ANOVA. The results were following. 1) The subjects consisted of male and female who was from teenage to fifty year old above. According to general characteristics, who endureed moderate cold-heat application, had constitutional fever, good sweat, and taked a cold bath accationally. And the woman think that their body were more cold than man. and the number of cold bath was less than man. Woman felt more harder than man that endured exposing cold. According to the recognitions of cold-heat applications, the 61.9% of the subjects think that cold application is more positive, and the 61.7% of the subjects think that heat application is more positive. 2) The subjects think that oral cavity, abdomen, back, extremes must be warm. 3) The percents of cold or heat application at abdomen were 77.4%, 86.5% respectely and the percents of cold or heat application at perineum were 56.9%. 93.6% respectely. With the above results. we know that the subjects have the fixed perceptions that each body part has to maintain its temperature. especially, they think that postpartum care is correlated with cold-heat application. So when we intervent nursing care, we also must regard their recognitions of cold and heat applications. and we need to educate and explain correctly about cold-heat application.

  • PDF

Impact of Lumen Size and Helical Coil Place Change in Spring on Orthodontic Force (Spring의 lumen size와 helical coil 형성 위치 변화가 교정력에 미치는 영향)

  • Lee, Gyu-Sun;Lee, Sun-Kyoung;Kim, Bok-Dong
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.331-337
    • /
    • 2011
  • Purpose: The purpose of this study was to impact of force system change in finger spring that add helical coil one round on orthodontic force. Methods: The following conclusions were drawn from the experiment conducted after bending 90 samples with a CNC wire forming machine while changing the height and lumen size to 1mm - 3mm - 5mm and 2mm - 3mm - 4mm respectively in the coil of the force system in finger spring added with one wheel of helical coil of 18-8 stainless steel round wire (${\Phi}0.5mm$, spring hard) from Jinsung Co. in domestic market under the following conditions: Laboratory name = Instron 5942; Temperature($deg^{\circ}C$) = 18.00; Humidity(%) = 50.00; Rate 1 = 10.00000 mm/min; Compressive extension = 5.0mm. Results: When Coil height is 1, 3, 5mm and lumen size is 2, 3, 4mm reduce finger spring as mean value of compressive extension occasion maximum load(mN) increases as coil height rises, and lumen size grows to 5.0mm. And was expose that compressive load(mN) increases as coil position of finger spring rises and increase as lumen size is decrescent. Conclusion: As the adherence height of coil was raised from 1mm through 3mm to 5mm, compressive load increased. As the lumen size increased from 2mm through 3mm to 4mm, compressive load decreased. Therefore, these results suggest that it is desirable to lower the coil height and enlarge the lumen size to enhance the biomechanical efficiency of finger spring when manufacturing the finger spring for removable orthodontic devices.

In Vitro Study Of Salivary Bacterial Adherence On e-PTFE Membrane According To Periodontal Status. (치주조직 상태에 따른 e-PTFE막 부착에 관한 연구)

  • Ju, Jae-Ig;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.117-132
    • /
    • 1996
  • The purpose of this study was to evaluate the bacterial adherence on e-PTFE membrane immersed in whole saliva from subjects with different periodontal status. Experiment involved 3 subject groups: 5 persons with healthy periodontium(probing depth below 3mm and no signs of gingival inflammation including bleeding on probing), 10 patients with gingivitis(probing depth below 3mm and apparent signs of gingival inflammation), and 10 patients with advanced periodontitis(probing depth over 7mm and apparent signs of gingival inflammation). Each disease group was included before and after scaling and root planing treatment. After obtaining whole saliva from each subject, e-PTFE membrane(Gore-Tex periodontal membrane : $GTPM^{(R)}$, W.L. Gore & Associates, Flagstaff, USA) specimens were immersed at room temperature in the saliva aliqouts for 1, 3, 7 days. The weight between pre - and post - immersion in saliva was measured with the analytical balance and the difference was recorded. The specimens were processed for SEM observation. The bacterial adherence on the membrane specimens was evaluated using the scanning electron microscope images. The obtained results were as follows : 1. There was no difference in the weight of bacteria adherent to e-PTFE membrane specimens according to the periodontal status and the immersion periods. 2. As the exposure time to saliva increased, the bacterial adherence to the membrane specimen significantly increased in all groups(P<0.005). 3. As the severity of periodontal disease increased, the bacterial adherence to the membrane specimens significantly increased(p<0.001). 4. After scaling and root planing, the bacterial adherence to the membrane specimens significantly decreased in gingivitis and periodontitis patient group(P<0.001). These results suggest that bacterial contamination on exposed barrier membrane surface be reduced through improvement of periodontal status and oral health environment before and after GTR procedure for the successful outcome.

  • PDF

THE EFFECTS OF METAL SURFACE TREATMENTS ON THE BONE STRENGTH OF POLYMETHYL METHACRYLATE BONDED REMOVABLE PROSTHESE (가철성 보철물의 금속면 처리방법이 열중합 레진과 금속간의 결합강도에 미치는 영향)

  • Eom, Tae-Wan;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.336-354
    • /
    • 1998
  • Traditionally, many kinds of mechanical bonding techniques were used for bonding resins to the surface of the metal alloys. If there is a seperation between resin and metal junction by stress accumulation and temperature change of oral cavity, the cracks or crazing may occur, accompanied by failure of resin bonding to metal. This study was designed to compare the shear bond strength of the type IV gold alloy and Cr-Co alloy surfaces treated with various methods and thermocycling. Universal Instron (Model 1000) and scanning electron microscope (JEOL, Japan) was used to record the shear bond strength of 5 groups. Forty specimens were made for each group ; group 1 was treated with sandblasting only, group 2 was coated with V-primer after sandblasting, group 3 was coated with Metal primer, group 4 wase coated with MR Bond and group 5 was coated with silane. After treated with various methods, thermocycling was done for half of the each group. The surfaces of failed pattern were observed with SEM. The results were as follows : 1. Shear bond strength of the group 1 was lower than that of another groups in type IV gold alloys and bond strength of the group 1, 2 were lower than that of group 3, 4, 5 in Cr-Co alloys. 2. Shear bond strength of the gold alloy with resin was higher than that of Cr-Co alloy when specimens were coated with V-primer. 3. Shear bond strength of the Co-Cr alloys with resin was higher than that of gold alloys when specimens were coated with Metal primer. 4. The bond strength of all specimens did not decreased significantly after thermocycling. 5. Adhesive failures were found in group 1 and Cr-Co alloy in group 2, but adhesive and cohesive failures were found in another groups.

  • PDF

Effect of the Heat-exposure on Peripheral Sudomotor Activity Including the Density of Active Sweat Glands and Single Sweat Gland Output

  • Lee, Jeong-Beom;Kim, Tae-Wook;Shin, Young-Oh;Min, Young-Ki;Yang, Hun-Mo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.14 no.5
    • /
    • pp.273-278
    • /
    • 2010
  • Tropical inhabitants are able to tolerate heat through permanent residence in hot and often humid tropical climates. The goal of this study was to clarify the peripheral mechanisms involved in thermal sweating pre and post exposure (heat-acclimatization over 10 days) by studying the sweating responses to acetylcholine (ACh), a primary neurotransmitter of sudomotor activity, in healthy subjects (n=12). Ten percent ACh was administered on the inner forearm skin for iontophoresis. Quantitative sudomotor axon reflex testing, after iontophoresis (2 mA for 5 min) with ACH, was performed to determine directly activated (DIR) and axon reflex-mediated (AXR) sweating during ACh iontophoresis. The sweat rate, activated sweat gland density, sweat gland output per single gland activated, as well as oral and skin temperature changes were measured. The post exposure activity had a short onset time (p<0.01), higher active sweat rate [(AXR (p<0.001) and DIR (p<0.001)], higher sweat output per gland (p<0.001) and higher transepidermal water loss (p<0.001) compared to the pre-exposure measurements. The activated sweat rate in the sudomotor activity increased the output for post-exposure compared to the pre-exposure measurements. The results suggested that post-exposure activity showed a higher active sweat gland output due to the combination of a higher AXR (DIR) sweat rate and a shorter onset time. Therefore, higher sudomotor responses to ACh receptors indicate accelerated sympathetic nerve responsiveness to ACh sensitivity by exposure to environmental conditions.

General Pharmacological Properties of the New +/K+ ATPase Inhibitor DBM-819

  • Park, Woo-Kyu;Kong, Jae-Yang;Kim, Hyun-Jung;Lee, Dong-Ha;Lim, Hong;Cheon, Hyae-Gyeong
    • Biomolecules & Therapeutics
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2002
  • The effects of a newly synthesized $H^+/K^+$ ATPase inhibitor,1-(2-methyl-4-methoxypheny)-4-[(3-hy-droxypropyl)amino] -6-methyl-2,3-dihydropyrrolo (3,2-c) quinoline (DBM-819) , on the central nervous system, isolated smooth muscle, cardiovascular and digestive systems and renal function were investigated in various experimental animals. Oral administration of DBM-819 had no effect on the central nervous system except body temperature of mice slightly decreased at doses of 15 and 50 mg/kg. DBM-819 produced a moderate analgesic effect in acetic acid-induced writhing test in mice at 50 mg/kg (p.o.). In conscious rats, DBM-819 (15 and 50 mg/kg, p.o.) showed a slight increase in blood pressure and a small decrease in heart rate. DBM-819 had an significant effect on agonist-induced contraction of guinea pig ileum at $1.5{\times}10^{-5}g/ml.$ No significant effect of DBM-819 (5 and 15 mg/kg, i.p) on urinary volume or urinary excretion of $Na^+,\;K^+$ and Cl- was observed in rats. DBM-819 had no significant effect on intestinal transport of a semisolid meal in mice at 15 and 50 mg/kg (p.o.). These findings suggest that DBM-819 exerts no significant pharmacological effects on the central nervous system and renal function at 15 mg/kg (p.o.), but produces some effects on the smooth muscle and circulatory system.

Acute Respiratory Failure due to Fatal Acute Copper Sulfate Poisoning : A Case Report (급성 호흡부전으로 사망한 황산구리 중독 1례)

  • Kim, Gun Bea
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.13 no.1
    • /
    • pp.36-39
    • /
    • 2015
  • Copper sulfate is a copper compound used widely in the chemical and agriculture industries. Most intoxication occurs in developing countries of Southeast Asia particularly India, but rarely occurs in Western countries. The early symptoms of intoxication are nausea, vomiting, diarrhea, and abdominal cramps, and the most distinguishable clue is bluish vomiting. The clinical signs of copper sulfate intoxication can vary according to the amount ingested. A 75-year old man came to our emergency room because he had taken approximately 250 ml copper sulfate per oral. His Glasgow Coma Scale (GCS) score was 14 and vital signs were blood pressure 173/111 mmHg, pulse rate 24 bpm, respiration rate 24 bpm, and body temperature $36.1^{\circ}$ .... Arterial blood gas analysis (ABGa) showed mild hypoxemia and just improved after 2 L/min oxygen supply via nasal cannula. Other laboratory tests and chest CT scan showed no clinical significance. Three hours later, the patient's mental status showed sudden deterioration (GCS 11), and ABGa showed hypercarbia. He was arrested and his spontaneous circulation returned after 8 minutes CPR. However, 22 minutes later, he was arrested again and returned after 3 minutes CPR. The family did not want additional resuscitation, so that he died 5 hours after ED visit. In my knowledge, early deaths are the consequence of shock, while late mortality is related to renal and hepatic failure. However, as this case shows, consideration of early definite airway preservation is reasonable in a case of supposed copper sulfate intoxication, because the patients can show rapid deterioration even when serious clinical manifestation are not presented initially.

  • PDF

Stability of 5-FU and Tegafur in Biological Fluids of Rats (흰쥐 생체시료 중 5-플루오로우라실 및 테가푸르의 안정성)

  • Jang, Ji-Hyun;Park, Jong-Kook;Kang, Jin-Hyoung;Chung, Suk-Jae;Shim, Chang-Koo;Kuh, Hyo-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.3
    • /
    • pp.161-168
    • /
    • 2004
  • 5-Fluorouracil (5-FU) is an antimetabolite anticancer agent active against many types of solid tumors. Tegafur (TF), a prodrug of 5-FU, is frequently used in combination with uracil as dihydropyrimidine dehydrogenase (DPD) inhibitory fluoropyrimidine. We studied the stability of 5-FU and TF in biological fluids of rats and determined their bioavailability (BA) and excretion into bile, and urine. The drug concentrations were analyzed by an HPLC method. At room temperature, there was a 14-30% decrease in the concentration of 5-FU and TF in bile, urine, and plasma specimen at 10 and $100\;{\mu}g/ml$ over 240 min. No significant difference was noted among the sample types or between two different concentrations of 10 and $100{\mu}g/ml$. The decrease in drug concentration was significantly less in samples kept on ice (6-12%) for both drugs. These data indicate that biological fluid samples containing 5-FU or TF in plasma, urine, or bile should be placed on ice during the sample collection. Following these storage guidelines, samples were collected after administration 50 mg/kg of each drug via i.v. or oral route. BA was 1.5 folds greater for TF (60%) than that of 5-FU (42%). Approximately 0.52 and 3.3% of the i.v. doses of 5-FU and TF was excreted into bile, respectively. Renal clearance of 5-FU was about 16% of its total body clearance. These results suggest that instability of 5-FU and TF in biological fluids should be considered in pharmacokinetic or pharmacogenomic studies.

Cancer Chemopreventive Properties of Processed Ginseng

  • Surh, Young-Joon
    • Proceedings of the Ginseng society Conference
    • /
    • 1998.06a
    • /
    • pp.270-280
    • /
    • 1998
  • Ginseng is one of the most widely used medicinal plants, particularly in East Asian countries. Certain fractions or purified ingredients of ginseng have been shown to exert inhibitory effects on growth of cancer cells in culture or on tumorigenesis in experimental animals. Moreover, a recent epidemiologic study reveals that ginseng intake is associated with a reduced risk for environmentally related cancers such as esophageal, gastric, colorectal, and pulmonary tumors. Heat treatment of Panax ginseng C. A. Meyer at the temperature higher than that applied to the conventional preparation of red ginseng yielded a mixture of saponins with potent antioxidative properties. Thus, the methanol extract of heat-processed ginseng (designated as'NGMe') attenuated lipid peroxidation in rat brain homogenates induced by ferric ion or ferric ion plus ascorbic acid. Furthermore, the extract protected against strand scission in f Xl 74 supercoiled DNA Induced by UV photolysis of H2O2 and was also capable of scavenging superoxide generated in vitro by xanthine/xanthine oxidate or in differentiated human promyelocytic leukemia (HL-60) cells by the tumor promoter,12-0-tetvade- canoylphorbol-13-acetate (TPA). Since tumor promotion is closely linked to oxidative stress, we have determined possible anti-tumor promotional effects of NGMe on two-stage mouse skin tumorigenesis. Topical application of NGMe onto shaven backs of female ICR mice 10 min prior to TPA significantly ameliorated skin papillomagenesi s initiated by 7,12-dimethylbenz (a) anthracene (DMBA).'Likewise, TPA-induced epidermal ornithine decarboxylase activity and elevation of tumor necrosis factor-a were suppressed signifies%fly by NGMe pretreatment. NGMe topically applied onto surface of hamster buccal pouch 10 min before each topical application of DMBA inhibited oral carcinogenesis by 76olo in terms of multiplicity. Taken together, these results suggest that processed Panax ginseng C. A. Meyer has potential cancer chemopreventive activities.

  • PDF