• Title/Summary/Keyword: optimum length

Search Result 1,487, Processing Time 0.03 seconds

형상에 따른 초전도 튜브의 전기적 특성변화

  • Jang, G.E.;Park, C.W.;Ha, D.W.;Seung, T.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.527-530
    • /
    • 2004
  • High-temperature Superconductor(HTS) tubes were fabricated in term of different diameter, length and thickness by centrigugal forming method. For powder melting by induction the optimum range of melting temperatures and preheating temperature were $1050^{\circ}C{\sim}1100^{\circ}C\;amd\;550^{\circ}C$ for 30min, respectively. The mould renting speed was 1000rpm. A tube was annealed at $840^{\circ}C$ for 72hours in oxygen atmosphere. The plate-like grains were well developed along the renting direction and typical grain size was about more than $40{\mu}m$. It was found that Ic values increased with increasing the tube diameter while the Ic decreased with increasing tube thickness. Also Ic decreased with increasing the tube length. The measured Ic in $50mm{\times}70mm{\times}25mm$ tube was about 896Amp.

  • PDF

사각형강목의 끝자루를 이용한 트롤어구의 어획선택성 연구 ( 2 ) - 다이아몬드형강목과 사각형강목의 선택성비교 - ( Studies on the Selectivity of the Trawl Net With the Square Mesh Cod-End ( 2 ) - Comparison of Diamond and Square Mesh Cod-End - )

  • Kim, Sam-Kon;Lee, Ju-Hee;Park , Jeong-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.172-181
    • /
    • 1994
  • The mesh selectivity of diamond and suare mesh cod-ends at the Southern Korean Sea and the East China Sea were compared for Pampus argenteus, Trachurus japonicus, Trichiurus lepturus. Selection trials were carried out using diamond and square mesh cod-end by trouser type cod-end with cover net. of which the mesh cod-end has four types : A(51.2mm), B(70.2mm), C(77.6mm), D(88.0mm). Selection curves and selection parameters were calculated using a logistic model. The results obained are summarized as follows : 1. Harvest fish : In B. C and D type selection range and fifty percent selection length of the square mesh were about 21mm, 11mm : 12mm, 18mm and 34mm, 5mm higher than those of the diamond mesh, respectively. Selection factor of master curve for the diamond mesh was 1.54 and for the square mesh was 1.68. The optimum mesh size for the diamond mesh was 97.4mm and for the square mesh was 89.3mm, the difference was 8.1mm. 2. Horse mackerel : In A type, selection range was nearly the same for the diamond and the square mesh, but fifty percent selection length of the square mesh was 43mm higher than the diamond mesh. In B. C and D type, selection range and fifty percent selection length of the square mesh were about 6mm, 3mm : 24mm, 21mm and 11mm, 42mm higher than those of the diamond mesh, respectively. Selection factor of master curve for the diamond mesh was 2.37, for the square mesh was 2.77. The optimum mesh size for the diamond mesh was 78.1mm and for the square mesh was 66.8mm, the difference was 11.3mm. 3. Hair tail : In A, B and C type, selection range of the square mesh was about 34mm, 8mm, 60mm higher than those of the diamond mesh. Fifty percent selection length for the diamond mesh was about 5mm, 7mm, 8mm higher than that of the square mesh. Selection factor of master curve for the diamond mesh was 3.11, for the square mesh was 3.48. The optimum mesh size for the diamond mesh was 64.3mm and for the square mesh was 57.5mm, the difference was 6.8mm.

  • PDF

Studies on the Seed Production of the Puffer Takifugu rubripes (Temminck et Schlegel) (자주복, Takifugu rubripes (Temminck et Schlegel)의 종묘양산에 관한 연구)

  • RHO Sum;JUNG Yun-Seok
    • Journal of Aquaculture
    • /
    • v.6 no.4
    • /
    • pp.295-310
    • /
    • 1993
  • As a part for the development of effective mass production techniqne of the puffer, Takifugu rubripes. seedfish, an investigation was carried out in 1989. 1991 and 1992 to determine the optimum starting feeding time of rotifers as a starting food for the fish larvae, and to find out the influences of the light intensitiy and LD cycles on the Artemia consumption by the larvae. The optimum starting time of feeding with rotifer. Brachionus Plicatilis was 2nd to 5th day from hatching resulting in survival of $96.5\~90.0\%$. Optimum light conditions for maximum feeding for fish larvae with Artemia were 1000 lux in 6mm, 600 lux in 8mm, and 200 lux in total length of 10-12 mm larvae. Relationship between total length (X: mm) of fish (6-12 mm in total length) and light intensity (Y: lux) for maximum feeding was:Y=2200-200X (r=-1.000). Relationship between days from hatching (X) and total length (Y: mm) of puffer fry was :Y=1.6427+0.2540X(r=0.9814) for 3 to 36 days after hatching, Y=-33.1452+1.1867X(r= 0.9854) for 36 to 68 days after hatching. Survival rate for 68 days after hatching was $24.1\%$ and the range of water temperature during this period was $21.25\pm1.67^{\circ}C$.

  • PDF

Studies on the Effective Utilization of Soybean - Part I. Experiments on the Improvement of Cultural Methods for Soybean Sprouts - (대두(大豆)의 효율적(效率的) 이용(利用)에 관(關)한 연구(硏究) - 제1보(第1報) 콩나물의 제조개선(製造改善)에 관(關)한 연구(硏究) -)

  • Yang, Cha-Bum;Lee, Sung-Woo;Ko, Young-Su;Yoon, Suk-Kwon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1979
  • To find out effective cultural methods of soybean sprouts, soaking time, irrigation number and culture temperature influencing on the soybean sprouts were investigated. The optimum soaking was the time which the soybean weight reached the double comparing the initial weight. The relationship between soaking time and temperature could be expressed as ${\hat{Y}}=-0.298x+14.463$(${\hat{Y}}$;time, x; temperature). The optimum number of irrigation was the four times per one day, observing the fresh weight of sprouts, length of axis, length of edible axis and length of roots. Considering only length of axis, optimum temperature was $25^{\circ}C$ but it was estimated to $21-22^{\circ}C$ minimizing the loss of dry weight and nitrogen.

  • PDF

Variable Length Optimum Convergence Factor Algorithm for Adaptive Filters (적응 필터를 위한 가변 길이 최적 수렴 인자 알고리듬)

  • Boo, In-Hyoung;Kang, Chul-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.77-85
    • /
    • 1994
  • In this study an adaptive algorithm with optimum convergence factor for steepest descent method is proposed, which controls automatically the filter order to take the appropriate level. So far, fixed order filters have been used when adaptive filter is employed according to the priori knowledge or experience in various adaptive signal processing applications. But, it is so difficult to know the filter order needed in real implementations that high order filters have to be performed. As a result, redundant calculations are increased in the case of high order filters. The proposed variable length optimum convergence factor (VLOCF) algorithm takes the appropriated filter order within the given one so that the redundant calculation is decreased to get the enhancement of convergence speed and smaller convergence error during the steady state. The proposed algorithm is evaluated to prove the validity by computer simulation for system Identification.

  • PDF

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

Thrust Performance and Plasma Acceleration Process of Hall Thrusters

  • Tahara, Hirokazu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.262-270
    • /
    • 2004
  • Basic experiments were carried out using the THT-IV low-power Hall thruster to examine the influences of magnetic field shape and strength, and acceleration channel length on thruster performance and to establish guidelines for design of high-performance Hall thrusters. Thrusts were measured with varying magnetic field and channel structure. Exhaust plasma diagnostic measurement was also made to evaluate plume divergent angles and voltage utilization efficiencies. Ion current spatial profiles were measured with a Faraday cup, and ion energy distribution functions were estimated from data with a retarding potential analyzer. The thruster was stably operated with a highest performance under an optimum acceleration channel length of 20 mm and an optimum magnetic field with a maximum strength of about 150 Gauss near the channel exit and with some shape considering ion acceleration directions. Accordingly, an optimum magnetic field and channel structure is considered to exist under an operational condition, related to inner physical phenomena of plasma production, ion acceleration and exhaust plasma feature. A new Hall thruster was designed with basic research data of the THT-IV thruster. With the thruster with many considerations, long stable operations were achieved. In all experiments at 200-400 V with 1.5-3 mg/s, the thrust and the specific impulse ranged from 15 to 70 mN and from 1100 to 2300 see, respectively, in a low electric power range of 300~1300 W. The thrust efficiency reached 55 %. Hence, a large map of the thruster performance was successfully made. The thermal characteristics were also examined with data of both measured and calculated temperatures in the thruster body. Thermally safe conditions were achieved with all input powers.

  • PDF

Optimum Combination of Pickup Coil Type and Magnetically Shielded Room for Maximum SNR to Measure Biomagnetism (생체신호 측정을 위한 최대의 신호 대 잡음비를 가지는 검출코일의 형태 와 자기차폐실의 최적 조합)

  • Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, J.M.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.45-49
    • /
    • 2007
  • We have investigated the optimum combination of the environmental noise condition and type of SQUID pickup coil in order to obtain maximum signal-to-noise ratio (SNR). The measurement probe consists of 1st order gradiometer with pickup coils of 100 mm, 70 mm, and 50 mm baseline length, a 2nd order gradiometer with 50 mm baseline, and a magnetometer. The pickup coils are fabricated by winding Nb wire on a bobbin with 200 mm diameter. Noise and heart signal of a healthy male were measured by various SQUID sensors with different types of pickup coils in various magnetically shielded rooms (MSR), and compared to each other. The shielding factors were found to be 43 dB, 35 dB and 25 dB at 0.1 Hz for MSR-AS, MSR-BS, MSR-CS, respectively. White noises were $3.5\;fT/Hz^{1/2}$, $4.5\;fT/Hz^{1/2}$ and $3\;fT/Hz^{1/2}$ for the 1st order gradiometers, the 2nd order gradiometers, and magnetometer for all MSRs. SNR of the magnetometer was up to 56 dB in MSR-AS, while the 1st order axial gradiometer with 70 mm baseline length was up to 54 dB in MSR-BS. The 2nd order axial gradiometer with 50 mm baseline length of pickup coil was found to be up to 40 dB in MSR-CS.

  • PDF

Effect of TiO2 Nanotube Length on Photocatalytic Activity with Different Light Intensities: Cr(VI) Reduction and Hydrogen Production (광량 및 TiO2 나노튜브 길이별 광활성 연구: Cr(VI)환원 및 수소제조)

  • Joo, Hyun-Ku;Shim, Eun-Jung;Lee, Jae-Min;Yoon, Jae-Kyung
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.4
    • /
    • pp.432-442
    • /
    • 2011
  • Anodized tubular $TiO_2$ electrodes (ATTEs) with three noticeably different lengths are prepared to determine their optimum length for the photo-driven activity in the reaction of Cr(VI) reduction and hydrogen evolution. The ATTEs with ethylene glycol have longer $TiO_2$ tubes (7-15.6 ${\mu}m$) than those with hydrfluoric acid (0.6-0.8 ${\mu}m$). These samples, which differ only in the length of the tubes, with a wall thickness of ca. 20 nm, consist mainly of an anatase crystalline phase after heat treatment at $650^{\circ}C$, since the anatase crystallites at the tube walls do not undergo transformation into rutile phase, due to the constraints imposed by the wall thickness. Among them, the medium size (ca. 8 ${\mu}m$) tubes provide the optimum conditions, irrespective of the light intensity, which is explained in terms of the correlation between the amount of photons and the adsorbed electron acceptors and their location. Photocatalytic Cr(VI) reduction leads to ca. 60% reduction of Cr(VI) even under 1 sun irradiation with the medium-sized anodized $TiO_2$ tubes, but only ca. 20% with the short- and long-sized tubes. For hydrogen evolution, tubes longer than 8 ${\mu}m$ do not exhibit better performance with any light intensity.

Automatic Control of the Comnbine(I) -Automatic guidance control of the head-feed combine- (콤바인의 자동제어에 관한 연구(I) -자탈형(自脱型) 콤바인의 주행방향제어(走行方向制御)-)

  • Chung, Chang-Joo;Kim, Seong-Ok;Kim, Soo-Sung
    • Journal of Biosystems Engineering
    • /
    • v.13 no.2
    • /
    • pp.38-45
    • /
    • 1988
  • This study was intended to develop the system automatically controlling travel direction of combine by means of sensing paddy rows. The control system was composed of three detecting levers having different length, micro-switch, microcomputer and electro-hydraulic control system. Sensor and control system developed was tested to estimate optimum design values and its actual performance as installed in combine. The computer simulation and performance test at simulated and actual field were conducted to test for possibility of practical use. The results of the study arc summarized. as follows: 1. The travel traces of combine hiving the conventional sensor with 2 levers and the new sensor detecting the slope of paddy rows were compared through computer simulation. Turning frequency of combine having new sensor was fewer than that of conventional sensor, but the rate of turning for the combine with new sensor was much greater than that of conventional sensor. 2. As sensor was established behind the tip of divider, the sensor itself well followed paddy rows but the tip of divider did not, resulting in divider being deviated from paddy rows. It was analyzed that the sensor should be attached closer to the tip of divider to have a better performance of the control system. 3. The greater the length of sensor lever for given location of sensor attachment and combine forward speed, the higher sensitivity of turning in control system. Moreover, increasing combine speed resulted in a worse performance of control system following paddy rows. Consequently, it was necessary that an optimum length of sensor attachment and for the range of combine operational speed. 4. Field test of combine installed with the sensor and electro-hydraulic system developed in this study showed that it may be operated smoothly and well behaved to paddy rows to 4th gear of combine speed which was 59cm/s. Consequently. it was concluded that the combine with the guidance control system developed in this study may be successfully used for paddy combining.

  • PDF