• 제목/요약/키워드: optimum electrode configuration

검색결과 4건 처리시간 0.017초

비침습적 복압 측정을 위한 생체 임피던스 전극의 최적 위치 선정 (Optimum electrode selection for measuring the abdominal pressure using bio-impedance method)

  • 안양수;김거식;송철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.46-48
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2$+0.0620x+0.6958, respectively. It demonstrated that the abdominal pressure could be measured non-invasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

  • PDF

생체 임피던스 방법을 이용하여 복압을 측정하기 위한 최적 전극위치 선정 (Optimum Electrode Selection for Measuring Abdominal Pressure using Bio-Impedance Method)

  • 김거식;이상옥;서정환;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권7호
    • /
    • pp.1339-1342
    • /
    • 2007
  • In this study, we determined the optimum electrode pair for measuring the abdominal pressure using bio-impedance method and compared with conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified using values of impedance change, correlation coefficient and SNR. Our results showed the optimum electrode pair (1, 9) which could detect impedance changes due to an increase of the intensity of the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. It demonstrated that the abdominal pressure could be measured noninvasively and simply using bio-impedance method. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of abdominal pressure by ambulatory urodynamics monitoring study.

요역동학 측정시스템을 위한 새로운 복압측정 기법 (A New Approach Method of Measuring Abdominal Pressure for Urodynamic Monitoring System)

  • 서정환;김거식;안양수;김경섭;송철규
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1170-1176
    • /
    • 2007
  • The conventional urodynamic monitoring is fulfilled by artificially filling a bladder with saline. Generally. it is difficult to evaluate the physiological functions of the storage and voiding of a bladder. With this aim, we constructed an ambulatory urodynamic monitoring (AUM) system and proposed a novel method estimating abdominal pressure by measuring bio-impedance variations. Our system was clinically evaluated for 10 patients. It turned out to be that as the intensity of the abdomen contraction increased, the amplitude of bio-impedance signal and the RMS value of EMG increased more as compared to those who observed during the rest mode. Also, we determined the optimum electrode pair for estimating the abdominal pressure using bio-impedance method and consequently compared with the conventional methods. Because impedance changes differ from a weight, a height, contractile force, volume of muscle and blood other or whatever of individuals, it was quantified in terms of impedance change, correlation coefficient and SNR Our results showed the optimum electrode pair (1,9) which could detect impedance changes due to the increase of the intensity in the abdominal pressure. The correlation coefficient and quadratic function between the RMS values of EMG and the impedance changes were 0.87 and $y=0.0014x^2+0.0620x+0.6958$, respectively. Thus, our system demonstrated that the abdominal pressure could be measured noninvasively and conveniently by simply estimating bio-impedance values. We propose that this optimum electrode configuration would be useful for the future studies involving the handy measurements of abdominal pressure with our suggested ambulatory urodynamics monitoring system.

Utilization of Waste Aluminium Foil as a Sacrificial Electrode for the Treatment of Wastewater

  • Perumalsamy, Rajagopal;Kumaran, Chithra;Rajamanickam, Vaishali
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.92-100
    • /
    • 2021
  • In this study, the use of waste food grade aluminium foil and mild steel as a sacrificial electrode in an electrocoagulation system was developed to remove reactive red 111 from wastewater. The effect of different parameters like pH, current density, electrode material, and different electrode configurations was investigated. Optimum operating conditions for maximum COD removal were determined as, 6 mA/㎠ current density and 30 min at 5 pH for aluminium foil and 7 pH for mild steel. Maximum COD reduction obtained at optimum conditions using monopolar 4 electrodes, monopolar 2 electrodes and bipolar electrode configuration were 96.5%, 89.3%, and 90.2% for Mild steel as a sacrificial electrode and 92.1%, 84.2%, and 88.6% for aluminium foil as a sacrificial electrode. The consumption of electrode and energy for both the electrodes of different configurations were calculated and compared. Using batch experimental data, a continuous-flow reactor was developed. Sludge analysis using Fourier Transform Infra-Red Spectroscopy (FTIR) analysis was done. Different adsorption kinetic models and isotherms were developed and it was found that pseudo second-order model and Langmuir isotherm fit best with the experimental data obtained.